SearcharxivSearch

arXiv subjects

K. Huitu

Publications and source records attributed to K. Huitu.

At least 19 recordsLinked to original sources

Optimization studies of silicon remoTES cryogenic calorimeters

The remoTES design, developed within the COSINUS experiment, enables a broader range of materials to be operated as cryogenic calorimeters read out with Transition Edge Sensors (TESs). In this configuration, the TES is fabricated onto a separate chip and thermally coupled to the absorber via a gold (Au) link. The remoTES concept has been successfully tested on various target materials. To further enhance detector performance and to fully exploit the advantages of the remote coupling design a series of optimization studies has been conducted using silicon (Si) absorbers as benchmark. This work presents an evaluation of several measurements aimed at reducing the thermal boundary resistance and enhancing signal transmission across Si remoTES interfaces, specifically from the absorber to the phonon collector and from the phonon collector to the TES. By testing a new Au link design and three distinct phonon collector configurations, Au, copper, and aluminum (Al)/Au, we achieved a baseline resolution of (21.5 +/- 0.3)eV using the Al/Au phonon collector.

physics.ins-det

Cosmic Ray Boosted Dark Matter in COSINUS: Modeling and Constraints

Direct detection of nuclear recoils due to sub-GeV dark matter is challenging because of the small kinetic energy of the light dark matter particles. Although limits down to a few hundred MeV have been reached using specially designed low threshold detectors, further improvements are now constrained more by background event rates than by energy thresholds. However, constraints down to sub-MeV dark matter masses can still be obtained through the boosted dark matter framework. In this scenario, high-energy cosmic rays or neutrinos scatter off dark matter particles, imparting additional kinetic energy and boosting them beyond the typical velocities expected from the non-relativistic dark matter halo. These boosted dark matter particles can then be detected even by experiments with higher energy thresholds. In this work, we present a catalog of dark matter - nucleon scattering cross sections corresponding to a heavy mediator limit for spin zero, one half and one dark matter and for scalar and vector mediators with even or odd parity. Based on these results, we present projected constraints on the dark matter - nucleon cross section for the COSINUS experiment, assuming an exposure of 100 kg d, demonstrating the potential sensitivity to sub-GeV boosted dark matter.

hep-ph

Defect Formation in NaI Crystals: A Novel Pathway to Dark Matter Detection

Sodium iodide (NaI) is a widely used scintillator in direct dark matter searches. In particular, NaI-based cryogenic scintillating calorimeters have emerged as promising candidates, like in the COSINUS experiment, for testing the annually modulating signal reported by DAMA/LIBRA. In this study, we investigate defect formation within NaI crystals and its impact on the dark matter detection signal. Using molecular dynamics simulations and density functional theory techniques, we simulate a DM particle collision on an NaI crystal, focusing on the possible defects formation and their structural and electronic properties. Our analysis includes a detailed study of the electronic states associated with the interstitial atoms and vacancies, the energetic cost of defect formation, and the anisotropic threshold displacement energy. Finally, we highlight the potential to exploit dark matter-induced defects as a novel detection channel, enabled by the introduction of new states within the electronic band gap.

hep-ph

Quenching factors for Na recoils as a function of Tl dopant concentrations in NaI(Tl) crystals

Thallium-doped sodium iodide (NaI(Tl)) scintillation detectors play an important role in the field of direct dark matter (DM) searches. The DAMA/LIBRA experiment stands out for its reported observation of an annually modulating DM-like signal, which is in direct contrast with other results. To accurately calibrate the energies of nuclear recoil signals with electron recoils, precise measurements of the quenching factor of the NaI(Tl) crystals are essential, as the two processes have different scintillation light yield. In this article, we present results of a systematic study carried out by the COSINUS collaboration and Duke University to measure the quenching factor of sodium (Na) recoils as a function of nuclear recoil energy and for differing Thallium (Tl) dopant concentrations in the bulk crystal. Five ultrapure NaI(Tl) crystals, manufactured by the Shanghai Institute for Ceramics, were irradiated with a quasi-monoenergetic neutron beam at the Triangle Universities Nuclear Laboratory, North Carolina, USA. The quenching factor for low nuclear recoil energies of 5-26keV$_{nr}$ was extracted for all 5 crystals. A Tl-dependence could be deduced with a proportional response calibration schema using a $^{241}$Am source. However, this effect was not observed when using a low-energy calibration line from $^{133}$Ba.

physics.ins-det

COSINUS -- a model-independent challenge of the DAMA/LIBRA dark matter claim with cryogenic NaI detectors operated in a new low-background facility

Low-temperature detectors are a powerful technology for dark matter search, offering excellent energy resolution and low energy thresholds. COSINUS is the only experiment that combines scintillating sodium iodide (NaI) crystals with an additional phonon readout at cryogenic temperatures, using superconducting sensors (remoTES), alongside the conventional scintillation light signal. Via the simultaneous phonon and scintillation light detection, a unique event-by-event particle identification is enabled. This dual-channel approach allows for a model-independent cross-check of the long-standing DAMA/LIBRA signal with a moderate exposure of a few hundred kg d, while completely avoiding key systematic uncertainties inherent to scintillation-only NaI-based searches. COSINUS built and commissioned a dedicated low-background cryogenic facility at the LNGS underground laboratories. Data taking with eight NaI detector modules (COSINUS1$\pi$ Run1) is planned to begin in late 2025.

physics.ins-det

COSINUS model-independent sensitivity to the DAMA/LIBRA dark matter signal

COSINUS is a dark matter direct detection experiment using NaI crystals as cryogenic scintillating calorimeters. If no signal is observed, this will constrain the dark matter scattering rate in sodium iodide. We investigate how this constraint can be used to infer that the annual modulation signal observed in the DAMA/LIBRA experiment cannot originate from dark matter nuclear recoil events, independently of the dark matter model. We achieve this by unfolding the DAMA modulation spectrum to obtain the implied unquenched nuclear recoil spectrum, which we then compare to the expected COSINUS sensitivity. We find that assuming zero background in the signal region, a 1$\sigma$, 2$\sigma$ or 3$\sigma$ confidence limit exclusion can be obtained with 57, 130 or 250 kg day of exposure, respectively. A simple background model indicates that in the presence of background, the exposure requirements may increase by $\sim30\%$.

hep-ph

Neutrino flux sensitivity to the next galactic core-collapse supernova in COSINUS

While neutrinos are often treated as a background for many dark matter experiments, these particles offer a new avenue for physics: the detection of core-collapse supernovae. Supernovae are extremely energetic, violent and complex events that mark the death of massive stars. During their collapse stars emit a large number of neutrinos in a short burst. These neutrinos carry 99\% of the emitted energy which makes their detection fundamental in understanding supernovae. This paper illustrates how COSINUS (Cryogenic Observatory for SIgnatures seen in Next-generation Underground Searches), a sodium iodide (NaI) based dark matter search, will be sensitive to the next galactic core-collapse supernova. The experiment is composed of two separate detectors which will be sensitive to far and nearby supernovae. The inner core of the experiment will consist of NaI crystals operating as scintillating calorimeters, mainly sensitive to the Coherent Elastic Scattering of Neutrinos (CE$\nu$NS) against the Na and I nuclei. The low mass of the cryogenic detectors gives the experiment a sensitivity to close supernovae below 1kpc without pileup. They will see up to hundreds of CE$\nu$NS events from a supernova happening at 200pc. The crystals reside at the center of a cylindrical 230T water tank, instrumented with 30 photomultipliers. This tank acts as a passive and active shield able to detect the Cherenkov radiation induced by impinging charged particles from ambient and cosmogenic radioactivity. A supernova near the Milky Way Center (10kpc) will be easily detected inducing $\sim$60 measurable events, and the water tank will have a 3$\sigma$ sensitivity to supernovae up to 22kpc, seeing $\sim$10 events. This paper shows how, even without dedicated optimization, modern dark matter experiments will also play their part in the multi-messenger effort to detect the next galactic core-collapse supernova.

astro-ph.HE

Water Cherenkov muon veto for the COSINUS experiment: design and simulation optimization

COSINUS is a dark matter (DM) direct search experiment that uses sodium iodide (NaI) crystals as cryogenic calorimeters. Thanks to the low nuclear recoil energy threshold and event-by-event discrimination capability, COSINUS will address the long-standing DM claim made by the DAMA/LIBRA collaboration. The experiment is currently under construction at the Laboratori Nazionali del Gran Sasso, Italy, and employs a large cylindrical water tank as a passive shield to meet the required background rate. However, muon-induced neutrons can mimic a DM signal therefore requiring an active veto system, which is achieved by instrumenting the water tank with an array of photomultiplier tubes (PMTs). This study optimizes the number, arrangement, and trigger conditions of the PMTs as well as the size of an optically invisible region. The objective was to maximize the muon veto efficiency while minimizing the accidental trigger rate due to the ambient and instrumental background. The final configuration predicts a veto efficiency of 99.63 $\pm$ 0.16 $\%$ and 44.4 $\pm$ $5.6\%$ in the tagging of muon events and showers of secondary particles, respectively. The active veto will reduce the cosmogenic neutron background rate to 0.11 $\pm$ 0.02 cts$\cdot$kg$^{-1}$$\cdot$year$^{-1}$, corresponding to less than one background event in the region of interest for the whole COSINUS-1$\pi$ exposure of 1000 kg$\cdot$days.

physics.ins-det

Particle discrimination in a NaI crystal using the COSINUS remote TES design

The COSINUS direct dark matter experiment situated at Laboratori Nazionali del Gran Sasso in Italy is set to investigate the nature of the annually modulating signal detected by the DAMA/LIBRA experiment. COSINUS has already demonstrated that sodium iodide crystals can be operated at mK temperature as cryogenic scintillating calorimeters using transition edge sensors, despite the complication of handling a hygroscopic and low melting point material. With results from a new COSINUS prototype, we show that particle discrimination on an event-by-event basis in NaI is feasible using the dual-channel readout of both phonons and scintillation light. The detector was mounted in the novel remoTES design and operated in an above-ground facility for 9.06 g$\cdot$d of exposure. With a 3.7 g NaI crystal, e$^-$/$\gamma$ events could be clearly distinguished from nuclear recoils down to the nuclear recoil energy threshold of 15 keV.

physics.ins-det

Deep-underground dark matter search with a COSINUS detector prototype

Sodium iodide (NaI) based cryogenic scintillating calorimeters using quantum sensors for signal read out have shown promising first results towards a model-independent test of the annually modulating signal detected by the DAMA/LIBRA dark matter experiment. The COSINUS collaboration has previously reported on the first above-ground measurements using a dual channel readout of phonons and light based on transition edge sensors (TESs) that allows for particle discrimination on an event-by-event basis. In this letter, we outline the first underground measurement of a NaI cryogenic calorimeter read out via the novel remoTES scheme. A 3.67 g NaI absorber with an improved silicon light detector design was operated at the Laboratori Nazionali del Gran Sasso, Italy. A significant improvement in the discrimination power of $e^-$/$\gamma$-events to nuclear recoils was observed with a five-fold improvement in the nuclear recoil baseline resolution, achieving $\sigma$ = 441 eV. Furthermore, we present a limit on the spin-independent dark-matter nucleon elastic scattering cross-section achieving a sensitivity of $\mathcal{O}$(pb) with an exposure of only 11.6 g d.

astro-ph.CO

First measurements of remoTES cryogenic calorimeters: easy-to-fabricate particle detectors for a wide choice of target materials

Low-temperature calorimeters based on a readout via Transition Edge Sensors (TESs) and operated below $100$ mK are well suited for rare event searches with outstanding resolution and low thresholds. We present first experimental results from two detector prototypes using a novel design of the thermometer coupling denoted remoTES, which further extends the applicability of the TES technology by including a wider class of potential absorber materials. In particular, this design facilitates the use of materials whose physical and chemical properties, as e.g. hygroscopicity, low hardness and low melting point, prevent the direct fabrication of the TES onto their surface. This is especially relevant in the context of the COSINUS experiment (Cryogenic Observatory for SIgnals seen in Next-Generation Underground Searches), where sodium iodide (NaI) is used as absorber material. With two remoTES prototype detectors operated in an above-ground R&D facility, we achieve energy resolutions of $σ=87.8$ eV for a $2.33$ g silicon absorber and $σ= 193.5$ eV for a $2.27$ g $α$-TeO$_{2}$ absorber, respectively. RemoTES calorimeters offer - besides the wider choice of absorber materials - a simpler production process combined with a higher reproducibility for large detector arrays and an enhanced radiopurity standard.

physics.ins-det

Simulation-based design study for the passive shielding of the COSINUS dark matter experiment

The COSINUS (Cryogenic Observatory for SIgnatures seen in Next-generation Underground Searches) experiment aims at the detection of dark matter-induced recoils in sodium iodide (NaI) crystals operated as scintillating cryogenic calorimeters. The detection of both scintillation light and phonons allows performing an event-by-event signal to background discrimination, thus enhancing the sensitivity of the experiment. The construction of the experimental facility is foreseen to start by 2021 at the INFN Gran Sasso National Laboratory (LNGS) in Italy. It consists of a cryostat housing the target crystals shielded from the external radioactivity by a water tank acting, at the same time, as an active veto against cosmic ray-induced events. Taking into account both environmental radioactivity and intrinsic contamination of materials used for cryostat, shielding and infrastructure, we performed a careful background budget estimation. The goal is to evaluate the number of events that could mimic or interfere with signal detection while optimising the geometry of the experimental setup. In this paper we present the results of the detailed Monte Carlo simulations we performed, together with the final design of the setup that minimises the residual amount of background particles reaching the detector volume.

physics.ins-det

The Compact Linear Collider (CLIC) - 2018 Summary Report

The Compact Linear Collider (CLIC) is a TeV-scale high-luminosity linear $e^+e^-$ collider under development at CERN. Following the CLIC conceptual design published in 2012, this report provides an overview of the CLIC project, its current status, and future developments. It presents the CLIC physics potential and reports on design, technology, and implementation aspects of the accelerator and the detector. CLIC is foreseen to be built and operated in stages, at centre-of-mass energies of 380 GeV, 1.5 TeV and 3 TeV, respectively. CLIC uses a two-beam acceleration scheme, in which 12 GHz accelerating structures are powered via a high-current drive beam. For the first stage, an alternative with X-band klystron powering is also considered. CLIC accelerator optimisation, technical developments and system tests have resulted in an increased energy efficiency (power around 170 MW) for the 380 GeV stage, together with a reduced cost estimate at the level of 6 billion CHF. The detector concept has been refined using improved software tools. Significant progress has been made on detector technology developments for the tracking and calorimetry systems. A wide range of CLIC physics studies has been conducted, both through full detector simulations and parametric studies, together providing a broad overview of the CLIC physics potential. Each of the three energy stages adds cornerstones of the full CLIC physics programme, such as Higgs width and couplings, top-quark properties, Higgs self-coupling, direct searches, and many precision electroweak measurements. The interpretation of the combined results gives crucial and accurate insight into new physics, largely complementary to LHC and HL-LHC. The construction of the first CLIC energy stage could start by 2026. First beams would be available by 2035, marking the beginning of a broad CLIC physics programme spanning 25-30 years.

physics.acc-ph

Prospects for charged Higgs searches at the LHC

The goal of this report is to summarize the current situation and discuss possible search strategies for charged scalars, in non-supersymmetric extensions of the Standard Model at the LHC. Such scalars appear in Multi-Higgs-Doublet models (MHDM), in particular in the popular Two-Higgs-Doublet model (2HDM), allowing for charged and additional neutral Higgs bosons. These models have the attractive property that electroweak precision observables are automatically in agreement with the Standard Model at the tree level. For the most popular version of this framework, Model~II, a discovery of a charged Higgs boson remains challenging, since the parameter space is becoming very constrained, and the QCD background is very high. We also briefly comment on models with dark matter which constrain the corresponding charged scalars that occur in these models. The stakes of a possible discovery of an extended scalar sector are very high, and these searches should be pursued in all conceivable channels, at the LHC and at future colliders.

hep-ph

Updated baseline for a staged Compact Linear Collider

The Compact Linear Collider (CLIC) is a multi-TeV high-luminosity linear e+e- collider under development. For an optimal exploitation of its physics potential, CLIC is foreseen to be built and operated in a staged approach with three centre-of-mass energy stages ranging from a few hundred GeV up to 3 TeV. The first stage will focus on precision Standard Model physics, in particular Higgs and top-quark measurements. Subsequent stages will focus on measurements of rare Higgs processes, as well as searches for new physics processes and precision measurements of new states, e.g. states previously discovered at LHC or at CLIC itself. In the 2012 CLIC Conceptual Design Report, a fully optimised 3 TeV collider was presented, while the proposed lower energy stages were not studied to the same level of detail. This report presents an updated baseline staging scenario for CLIC. The scenario is the result of a comprehensive study addressing the performance, cost and power of the CLIC accelerator complex as a function of centre-of-mass energy and it targets optimal physics output based on the current physics landscape. The optimised staging scenario foresees three main centre-of-mass energy stages at 380 GeV, 1.5 TeV and 3 TeV for a full CLIC programme spanning 22 years. For the first stage, an alternative to the CLIC drive beam scheme is presented in which the main linac power is produced using X-band klystrons.

physics.acc-ph

The LBNO long-baseline oscillation sensitivities with two conventional neutrino beams at different baselines

The proposed Long Baseline Neutrino Observatory (LBNO) initially consists of $\sim 20$ kton liquid double phase TPC complemented by a magnetised iron calorimeter, to be installed at the Pyhäsalmi mine, at a distance of 2300 km from CERN. The conventional neutrino beam is produced by 400 GeV protons accelerated at the SPS accelerator delivering 700 kW of power. The long baseline provides a unique opportunity to study neutrino flavour oscillations over their 1st and 2nd oscillation maxima exploring the $L/E$ behaviour, and distinguishing effects arising from $δ_{CP}$ and matter. In this paper we show how this comprehensive physics case can be further enhanced and complemented if a neutrino beam produced at the Protvino IHEP accelerator complex, at a distance of 1160 km, and with modest power of 450 kW is aimed towards the same far detectors. We show that the coupling of two independent sub-MW conventional neutrino and antineutrino beams at different baselines from CERN and Protvino will allow to measure CP violation in the leptonic sector at a confidence level of at least $3σ$ for 50\% of the true values of $δ_{CP}$ with a 20 kton detector. With a far detector of 70 kton, the combination allows a $3σ$ sensitivity for 75\% of the true values of $δ_{CP}$ after 10 years of running. Running two independent neutrino beams, each at a power below 1 MW, is more within today's state of the art than the long-term operation of a new single high-energy multi-MW facility, which has several technical challenges and will likely require a learning curve.

hep-ph

Optimised sensitivity to leptonic CP violation from spectral information: the LBNO case at 2300 km baseline

One of the main goals of the Long Baseline Neutrino Observatory (LBNO) is to study the $L/E$ behaviour (spectral information) of the electron neutrino and antineutrino appearance probabilities, in order to determine the unknown CP-violation phase $δ_{CP}$ and discover CP-violation in the leptonic sector. The result is based on the measurement of the appearance probabilities in a broad range of energies, covering t he 1st and 2nd oscillation maxima, at a very long baseline of 2300 km. The sensitivity of the experiment can be maximised by optimising the energy spectra of the neutrino and anti-neutrino fluxes. Such an optimisation requires exploring an extended range of parameters describing in details the geometries and properties of the primary protons, hadron target and focusing elements in the neutrino beam line. In this paper we present a numerical solution that leads to an optimised energy spectra and study its impact on the sensitivity of LBNO to discover leptonic CP violation. In the optimised flux both 1st and 2nd oscillation maxima play an important role in the CP sensitivity. The studies also show that this configuration is less sensitive to systematic errors (e.g. on the total event rates) than an experiment which mainly relies on the neutrino-antineutrino asymmetry at the 1st maximum to determine the existence of CP-violation.

hep-ph

The mass-hierarchy and CP-violation discovery reach of the LBNO long-baseline neutrino experiment

The next generation neutrino observatory proposed by the LBNO collaboration will address fundamental questions in particle and astroparticle physics. The experiment consists of a far detector, in its first stage a 20 kt LAr double phase TPC and a magnetised iron calorimeter, situated at 2300 km from CERN and a near detector based on a high-pressure argon gas TPC. The long baseline provides a unique opportunity to study neutrino flavour oscillations over their 1st and 2nd oscillation maxima exploring the $L/E$ behaviour, and distinguishing effects arising from $δ_{CP}$ and matter. In this paper we have reevaluated the physics potential of this setup for determining the mass hierarchy (MH) and discovering CP-violation (CPV), using a conventional neutrino beam from the CERN SPS with a power of 750 kW. We use conservative assumptions on the knowledge of oscillation parameter priors and systematic uncertainties. The impact of each systematic error and the precision of oscillation prior is shown. We demonstrate that the first stage of LBNO can determine unambiguously the MH to $>5σ$C.L. over the whole phase space. We show that the statistical treatment of the experiment is of very high importance, resulting in the conclusion that LBNO has $\sim$ 100% probability to determine the MH in at most 4-5 years of running. Since the knowledge of MH is indispensable to extract $δ_{CP}$ from the data, the first LBNO phase can convincingly give evidence for CPV on the $3σ$C.L. using today's knowledge on oscillation parameters and realistic assumptions on the systematic uncertainties.

hep-ph