Searcharxiv⌕ Search

arXiv subjects

K. J. Vetter

Publications and source records attributed to K. J. Vetter.

7 recordsLinked to original sources

DMRadio-Core: A new approach for GUT-scale axion searches

Searches for QCD axions with masses in the neV/$c^2$ mass range are strongly motivated by new physics at the GUT scale and by well-motivated pre-inflationary axion symmetry breaking scales. This parameter space is challenging to probe due to the small axion-photon couplings, which typically require large, high-field magnets with substantial stored energy. In this paper, we propose a new experimental geometry based on a narrow-bore, segmented solenoid that optimizes the collection of the axion-induced signal using LC resonators outside the high-field region of the magnet bore. This alternative optimization significantly reduces the required stored magnetic energy while preserving sensitivity, enabling a near-term experiment in the 30-200 MHz (120-830 neV/$c^2$) range, with a cost-effective, staged scaling to a GUT-scale experiment in the 100 kHz-30 MHz (0.4-120 neV/$c^2$) range.

hep-ex↗

The Cryogenic System of DMRadio-50L

The DMRadio-50L experiment is designed to search for axion dark matter in the 5 kHz - 5 MHz frequency range using a lumped-element LC resonator and a toroidal magnet and to serve as a testbed for quantum sensors. This paper describes the custom cryogenic system developed to meet the stringent requirements of the experiment within a standard laboratory environment. The system is designed to cool a 200 kg detector assembly to temperatures as low as 50 mK while providing sufficient cooling power at multiple temperature stages. We present the conceptual design, technical implementation, and measured performance of the hybrid cryogenic system, which combines a horizontal dilution refrigerator with a large vertical payload cryostat.

physics.ins-det↗

Vibrational sensing at mK temperatures in dry dilution refrigerators using commercial accelerometers for diverse fundamental physics applications

This article presents an evaluation of off-the-shelf commercial accelerometers at the mixing chamber stage of a cryogen-free dilution refrigerator at temperatures down to 8 mK. In addition, we present results of radioassay of accelerometers using a high purity germanium detector counting setup. Cryogen-free dilution refrigerators using pulse-tube cryocoolers (PTs) -- due to recent advances in their cooling capacity, long-term stability, and operational costs -- have become ubiquitous tools in a wide range of fields ranging from experimental particle physics to quantum information sciences. However, vibrations induced by PTs can negatively impact the experimental payload in these applications. This work demonstrates that commercially available accelerometers can not only measure vibrations at millikelvin cryogenic temperatures but also pave the way for continuous, in situ, real-time vibration monitoring of dry dilution refrigerators. This monitoring capability facilitates applications such as real-time denoising for vibration-sensitive experiments, thereby enabling ongoing noise assessment and mitigation.

physics.ins-det↗

Community Report from the 2025 SNOLAB Future Projects Workshop

SNOLAB hosts a biannual Future Projects Workshop (FPW) with the goal of encouraging future project stakeholders to present ideas, concepts, and needs for experiments or programs that could one day be hosted at SNOLAB. The 2025 FPW was held in the larger context of a 15-year planning exercise requested by the Canada Foundation for Innovation. This report collects input from the community, including both contributions to the workshop and contributions that could not be scheduled in the workshop but nonetheless are important to the community.

hep-ex↗

The environmental low-frequency background for macro-calorimeters at the millikelvin scale

Many of the most sensitive physics experiments searching for rare events, like neutrinoless double beta ($0νββ$) decay and dark matter interactions, rely on cryogenic macro-calorimeters operating at the mK-scale. Located underground at the Gran Sasso National Laboratory (LNGS), in central Italy, CUORE (Cryogenic Underground Observatory for Rare Events) is one of the leading experiments for the search of $0νββ$ decay, implementing the low-temperature calorimetric technology. We present a novel multi-detector analysis to correlate environmental phenomena with the low-frequency noise of low-temperature calorimeters. Indeed, the correlation of marine and seismic data with data from a pair of CUORE detectors indicates that cryogenic detectors are sensitive not only to intense vibrations generated by earthquakes, but also to the much fainter vibrations induced by marine microseisms in the Mediterranean Sea due to the motion of sea waves. Proving that cryogenic macro-calorimeters are sensitive to such environmental sources of noise opens the possibility of studying their impact on the detectors physics-case sensitivity. Moreover, this study could pave the road for technology developments dedicated to the mitigation of the noise induced by marine microseisms, from which the entire community of cryogenic calorimeters can benefit.

physics.ins-det↗

Large area photon calorimeter with Ir-Pt bilayer transition-edge sensor for the CUPID experiment

CUPID is a next-generation neutrinoless double-beta decay experiment that will require cryogenic light detectors to improve background suppression, via the simultaneous readout of heat and light channels from its scintillating crystals. In this work we showcase light detectors based on a novel Ir-Pt bilayer transition edge sensor. We have performed a systematic study to improve the thermal coupling between the photon absorber and the sensor, and thereby its responsivity. Our first devices meet CUPID's baseline noise requirement of <100~eV rms. Our detectors have risetimes of $\sim$180 $μ$s and measured timing jitter of <20 $μ$s for the expected signal-to-noise at the Q-value of the decay, which achieves the CUPID's criterion of rejecting two-neutrino double-beta decay pileup events. The current work will inform the fabrication of future devices, culminating in the final TES design and a scaleable readout scheme for CUPID.

physics.ins-det↗

Search for Double-Beta Decay of $\mathrm{^{130}Te}$ to the $0^+$ States of $\mathrm{^{130}Xe}$ with CUORE

The CUORE experiment is a large bolometric array searching for the lepton number violating neutrino-less double beta decay ($0νββ$) in the isotope $\mathrm{^{130}Te}$. In this work we present the latest results on two searches for the double beta decay (DBD) of $\mathrm{^{130}Te}$ to the first $0^{+}_2$ excited state of $\mathrm{^{130}Xe}$: the $0νββ$ decay and the Standard Model-allowed two-neutrinos double beta decay ($2νββ$). Both searches are based on a 372.5 kg$\times$yr TeO$_2$ exposure. The de-excitation gamma rays emitted by the excited Xe nucleus in the final state yield a unique signature, which can be searched for with low background by studying coincident events in two or more bolometers. The closely packed arrangement of the CUORE crystals constitutes a significant advantage in this regard. The median limit setting sensitivities at 90\% Credible Interval (C.I.) of the given searches were estimated as $\mathrm{S^{0ν}_{1/2} = 5.6 \times 10^{24} \: \mathrm{yr}}$ for the ${0νββ}$ decay and $\mathrm{S^{2ν}_{1/2} = 2.1 \times 10^{24} \: \mathrm{yr}}$ for the ${2νββ}$ decay. No significant evidence for either of the decay modes was observed and a Bayesian lower bound at $90\%$ C.I. on the decay half lives is obtained as: $\mathrm{(T_{1/2})^{0ν}_{0^+_2} > 5.9 \times 10^{24} \: \mathrm{yr}}$ for the $0νββ$ mode and $\mathrm{(T_{1/2})^{2ν}_{0^+_2} > 1.3 \times 10^{24} \: \mathrm{yr}}$ for the $2νββ$ mode. These represent the most stringent limits on the DBD of $^{130}$Te to excited states and improve by a factor $\sim5$ the previous results on this process.

nucl-ex↗