SearcharxivSearch

arXiv subjects

K. Kanaki

Publications and source records attributed to K. Kanaki.

At least 19 recordsLinked to original sources

Light-yield response of liquid scintillators using 2--6 MeV tagged neutrons

Knowledge of the neutron light-yield response is crucial to the understanding of scintillator-based neutron detectors. In this work, neutrons from 2--6 MeV have been used to study the scintillation light-yield response of the liquid scintillators NE 213A, EJ 305, EJ 331 and EJ 321P using event-by-event waveform digitization. Energy calibration was performed using a GEANT model to locate the edge positions of the Compton distributions produced by gamma-ray sources. The simulated light yield for neutrons from a PuBe source was compared to measured recoil proton distributions, where neutron energy was selected by time-of-flight. This resulted in an energy-dependent Birks parametrization to characterize the non-linear response to the lower energy neutrons. The NE 213A and EJ 305 results agree very well with existing data and are reproduced nicely by the simulation. New results for EJ 331 and EJ 321P, where the simulation also reproduces the data well, are presented.

physics.ins-det

Evaluation of a method for time-of-flight, wavelength and distance calibration for neutron scattering instruments by means of a mini-chopper and standard neutron monitors

Accurate conversion of neutron time-of-flight (TOF) to wavelength, and its uncertainty, is of fundamental importance to neutron scattering measurements. Especially in cases where instruments are highly configurable, the determination of the absolute wavelength after any change must always be performed. Inspired by the manner with which neutron spectrometers determine the absolute wavelength, we evaluate for the first time, in the author's knowledge, a commonly used method for converting TOF to neutron wavelength, the distance of a monitor from the source of neutrons and we analytically calculate the uncertainty contributions that limit the precision of the conversion. The method was evaluated at the V20 test beamline at the Helmholtz Zentrum Berlin (HZB), emulating the ESS source with a pulse of 2.86 ms length and 14 Hz repetition rate, by using a mini-chopper operated at 140 Hz, beam monitors (BMs) and data acquisition infrastructure. The mini-chopper created well-defined neutron pulses and the BM was placed at two positions, enabling the average wavelength of each of the pulses created to be determined. The used experimental setup resulted in absolute wavelength determination at the monitor positions with a $δλ_{mean} / λ_{mean}$ of $\sim$1.8% for $λ>4$ Å. With a modest increase of the distance between the reference monitor positions a $δλ_{mean} / λ_{mean}$ of below 0.5% can be achieved. Further improvements are possible by using a thinner monitor, smaller chopper disc openings and a higher rotational speed chopper. The method requires only two neutron measurements and doesn't necessitate the use of crystals or complex fitting, and could constitute a suitable addition to imaging, diffraction, reflectometers and small angle neutron scattering instruments, at spallation sources, that do not normally utilise fast choppers.

physics.ins-det

Technique for the measurement of intrinsic pulse-shape discrimination for organic scintillators using tagged neutrons

Fast-neutron/gamma-ray pulse-shape discrimination has been performed for the organic liquid scintillators NE 213A and EJ 305 using a time-of-flight based neutron-tagging technique and waveform digitization on an event-by-event basis. Gamma-ray sources and a Geant4-based simulation were used to calibrate the scintillation-light yield. The difference in pulse shape for the neutron and gamma-ray events was analysed by integrating selected portions of the digitized waveform to produce a figure-of-merit for neutron/gamma-ray separation. This figure-of-merit has been mapped as a function of detector threshold and also of neutron energy determined from time-of-flight. It shows clearly that the well-established pulse-shape discrimination capabilities of NE 213A are superior to those of EJ 305. The extra information provided by the neutron-tagging technique has resulted in a far more detailed assessment of the pulse-shape discrimination capabilities of these organic scintillators.

physics.ins-det

Multitube monitors: a new-generation of neutron beam monitors

With the renewal of many neutron science instruments and the commissioning of new neutron facilities, there is a rising demand for improved neutron beam monitoring systems with reduced beam perturbations and higher counting rate capability. Fission chambers are the most popular beam monitors; however, their use on some instruments may be prevented by the background generated by fast neutrons emitted during neutron captures in 235U and by neutrons scattered in the material of the fission chamber. Multitube detectors, on the other hand, offer a good alternative with minimum beam perturbations. The purpose of this paper is to report and analyse the results of the measurements performed with several Multitubes used for beam monitoring. We show that the transparency of Multitube beam monitors is 97.6 +/-0.4 %, and that their detection efficiency is uniform, with a deviation from the mean value < 0.7%. A counting rate reduction of 10% due to pile-up effects is measured at a rate of 550 kHz. In addition to neutron beam intensity monitoring, the Multitube can be configured for 1-dimensional or 2-dimensional localisation. We present the preliminary results of these additional functionalities.

physics.ins-det

Uniformity of response of Uranium fission chambers used as neutron beam monitors

Uranium fission chambers are commonly used for neutron beam monitoring in neutron research facilities. The challenges brought with the renewing or commissioning of new neutron facilities encourage to minimize the interaction between the monitor and the neutron beam. In order to characterize both their detection efficiency and transmission factor, several fission chambers, have been scanned on the CT1 monochromatic beam line of the ILL. Results show that the monitor transparency, measured at the center of the monitor, varies from 90% to 96%, and that the detection efficiency varies by as much as 50% over the active area.

physics.ins-det

Geant4-based calibration of an organic liquid scintillator

A light-yield calibration of an NE 213A organic liquid scintillator detector has been performed using both monoenergetic and polyenergetic gamma-ray sources. Scintillation light was detected in a photomultiplier tube, and the corresponding pulses were subjected to waveform digitization on an event-by-event basis. The resulting Compton edges have been analyzed using a Geant4 simulation of the detector which models both the interactions of the ionizing radiation as well as the transport of scintillation photons. The simulation is calibrated and also compared to well-established prescriptions used to determine the Compton edges, resulting ultimately in light-yield calibration functions. In the process, the simulation-based method produced information on the gain and intrinsic pulse-height resolution of the detector. It also facilitated a previously inaccessible understanding of the systematic uncertainties associated with the calibration of the scintillation-light yield. The simulation-based method was also compared to well-established numerical prescriptions for locating the Compton edges. Ultimately, the simulation predicted as much as 17% lower light-yield calibrations than the prescriptions. These calibrations indicate that approximately 35% of the scintillation light associated with a given gamma-ray reaches the photocathode. It is remarkable how well two 50 year old prescriptions for calibrating scintillation-light yield in organic scintillators have stood the test of time.

physics.ins-det

Self-Shielding Copper Substrate Neutron Supermirror Guides

The invention of self-shielding copper substrate neutron guides is described, along with the rationale behind the development, and the realisation of commercial supply. The relative advantages with respect to existing technologies are quantified. These include ease of manufacture, long lifetime, increased thermal conductivity, and enhanced fast neutron attenuation in the keV-MeV energy range. Whilst the activation of copper is initially higher than for other material options, for the full energy spectrum, many of the isotopes are short-lived, so that for realistic maintenance access times the radiation dose to workers is expected to be lower than steel and in the lowest zoning category for radiation safety outside the spallation target monolith. There is no impact on neutron reflectivity performance relative to established alternatives, and the manufacturing cost is similar to other polished metal substrates.

physics.ins-det

Simulation of the Response of the Solid State Neutron Detector for the European Spallation Source

The characteristics of the Solid-state Neutron Detector, under development for neutron-scattering measurements at the European Spallation Source, have been simulated with a Geant4-based computer code. The code models the interations of thermal neutrons and ionising radiation in the 6Li-doped scintillating glass of the detector, the production of scintillation light and the transport of optical, scintillation photons through the the scintillator, en route to the photo-cathode of the attached multi-anode photomultiplier. Factors which affect the optical-photon transport, such as surface finish, pixelation of the glass sheet, provision of a front reflector and optical coupling media are compared. Predictions of the detector response are compared with measurements made with neutron and gamma-ray sources, a collimated alpha source and finely collimated beams of 2.5 MeV protons and deuterons.

physics.ins-det

Time- and energy-resolved effects in the boron-10 based Multi-Grid and helium-3 based thermal neutron detectors

The boron-10 based Multi-Grid detector is being developed as an alternative to helium-3 based neutron detectors. At the European Spallation Source, the detector will be used for time-of-flight neutron spectroscopy at cold to thermal neutron energies. The objective of this work is to investigate fine time- and energy-resolved effects of the Multi-Grid detector, down to a few $μ$eV, while comparing it to the performance of a typical helium-3 tube. Furthermore, it is to characterize differences between the detector technologies in terms of internal scattering, as well as the time reconstruction of ~ $μ$s short neutron pulses. The data were taken at the Helmholtz Zentrum Berlin, where the Multi-Grid detector and a helium-3 tube were installed at the ESS test beamline, V20. Using a Fermi-chopper, the neutron beam of the reactor was chopped into a few tens of $μ$s wide pulses before reaching the detector, located a few tens of cm downstream. The data of the measurements show an agreement between the derived and calculated neutron detection efficiency curve. The data also provide fine details on the effect of internal scattering, and how it can be reduced. For the first time, the chopper resolution was comparable to the timing resolution of the Multi-Grid detector. This allowed a detailed study of time- and energy resolved effects, as well as a comparison with a typical helium-3 tube.

physics.ins-det

Response of a Li-glass/multi-anode photomultiplier detector to collimated thermal-neutron beams

The response of a position-sensitive Li-glass scintillator detector being developed for thermal-neutron detection with 6 mm position resolution has been investigated using collimated beams of thermal neutrons. The detector was moved perpendicularly through the neutron beams in 0.5 to 1.0 mm horizontal and vertical steps. Scintillation was detected in an 8 X 8 pixel multi-anode photomultiplier tube on an event-by-event basis. In general, several pixels registered large signals at each neutron-beam location. The number of pixels registering signal above a set threshold was investigated, with the maximization of the single-hit efficiency over the largest possible area of the detector as the primary goal. At a threshold of ~50% of the mean of the full-deposition peak, ~80% of the events were registered in a single pixel, resulting in an effective position resolution of ~5 mm in X and Y. Lower thresholds generally resulted in events demonstrating higher pixel multiplicities, but these events could also be localized with ~5 mm position resolution.

physics.ins-det

Parasitic neutron beam monitoring: proof of concept on gamma monitoring of neutron chopper phases

Neutron beam monitors are an essential diagnostic component of neutron scattering facilities. They are used to measure neutron flux, calibrating experiments performed on the instruments, allowing measurement of facility performance, understanding of the effect on the neutrons of beam-line components (such as choppers), calibration of detectors and tracking of beam stability. Ideally beam monitors {should} not perturb the beam. Previous work shows commercial beam monitors attenuate the beam by a few percent in the worst case due to the 1-2 mm thick Aluminium entrance and exit windows and the material inside. Parasitic methods of neutron beam diagnostics, where there is no beam monitor directly in the beam, would be preferable. This paper presents the concept of a parasitic method of monitoring the beam which can be used for neutron chopper phasing. This is achieved by placing a gamma detector close to a rotating chopper and measures a signal proportional to the flux absorbed by the chopper. Neutrons interact with the Boron absorber on the chopper disc lead to gamma emission at 480 keV. Detection of these gamma rays is used to determine the chopper phasing and timing. Potentially information on the flux of the beamline can be extracted. Results from a proof of concept implementation show that diagnosis of neutron chopper phases is feasible.

physics.ins-det

A simulational study of the indirect geometry neutron spectrometer, BIFROST at the European Spallation Source, from neutron source position to detector position

The European Spallation Source (ESS) is intended to become the most powerful spallation neutron source in the world and the flagship of neutron science in the upcoming decades. The exceptionally high neutron flux will provide unique opportunities for scientific experiments, but also set high requirements for the detectors. One of the most challenging aspects is the rate capability and in particular the peak instantaneous rate capability, i.e. the number of neutrons hitting the detector per channel or cm$^2$ at the peak of the neutron pulse. The primary purpose of this paper is to estimate the incident rates that are anticipated for the BIFROST instrument planned for ESS, and also to demonstrate the use of powerful simulation tools for the correct interpretation of neutron transport in crystalline materials. A full simulation model of the instrument from source to detector position, implemented with the use of multiple simulation software packages is presented. For a single detector tube instantaneous incident rates with a maximum of 1.7 GHz for a Bragg peak from a single crystal, and 0.3 MHz for a vanadium sample are found. This paper also includes the first application of a new pyrolytic graphite model, and a comparison of different simulation tools to highlight their strengths and weaknesses.

physics.ins-det

New high-sensitivity searches for neutrons converting into antineutrons and/or sterile neutrons at the European Spallation Source

The violation of Baryon Number, $\mathcal{B}$, is an essential ingredient for the preferential creation of matter over antimatter needed to account for the observed baryon asymmetry in the universe. However, such a process has yet to be experimentally observed. The HIBEAM/NNBAR %experiment program is a proposed two-stage experiment at the European Spallation Source (ESS) to search for baryon number violation. The program will include high-sensitivity searches for processes that violate baryon number by one or two units: free neutron-antineutron oscillation ($n\rightarrow \bar{n}$) via mixing, neutron-antineutron oscillation via regeneration from a sterile neutron state ($n\rightarrow [n',\bar{n}'] \rightarrow \bar{n}$), and neutron disappearance ($n\rightarrow n'$); the effective $Δ\mathcal{B}=0$ process of neutron regeneration ($n\rightarrow [n',\bar{n}'] \rightarrow n$) is also possible. The program can be used to discover and characterise mixing in the neutron, antineutron, and sterile neutron sectors. The experiment addresses topical open questions such as the origins of baryogenesis, the nature of dark matter, and is sensitive to scales of new physics substantially in excess of those available at colliders. A goal of the program is to open a discovery window to neutron conversion probabilities (sensitivities) by up to three orders of magnitude compared with previous searches. The opportunity to make such a leap in sensitivity tests should not be squandered. The experiment pulls together a diverse international team of physicists from the particle (collider and low energy) and nuclear physics communities, while also including specialists in neutronics and magnetics.

physics.ins-det

Response of a Li-glass/multi-anode photomultiplier detector to focused proton and deuteron beams

The response of a position-sensitive Li-glass based scintillation detector to focused beams of 2.5 MeV protons and deuterons has been investigated. The beams were scanned across the detector in 0.5 mm horizontal and vertical steps perpendicular to the beams. Scintillation light was registered using an 8 by 8 pixel multi-anode photomultiplier tube. The signal amplitudes were recorded for each pixel on an event-by-event basis. Several pixels generally registered considerable signals at each beam location. The number of pixels above set thresholds were investigated, with the optimization of the single-hit efficiency over the largest possible area as the goal. For both beams, at a threshold of ~50% of the mean of the full-deposition peak, ~80% of the events were registered in a single pixel, resulting in an effective position resolution of ~5 mm in X and Y.

physics.ins-det

Performance evaluation of the Boron Coated Straws detector with Geant4

The last decade has witnessed the development of several alternative neutron detector technologies, as a consequence of upcoming neutron sources and upgrades, as well the world-wide shortage of $^3$He. One branch of development is the family of $^{10}$B-based gaseous detectors. This work focuses on the boron coated straws (BCS) by Proportional Technologies Inc., a commercial solution designed for use in homeland security and neutron science. A detailed Geant4 simulation study of the BCS is presented, which investigates various aspects of the detector performance, e.g. efficiency, activation, absorption and the impact of scattering on the measured signal. The suitability of the BCS detector for Small Angle Neutron Scattering (SANS), direct chopper spectrometry and imaging is discussed.

physics.ins-det

Response of a Li-glass/multi-anode photomultiplier detector to $α$-particles from $^{241}$Am

The response of a position-sensitive Li-glass scintillator detector to $α$-particles from a collimated $^{241}$Am source scanned across the face of the detector has been measured. Scintillation light was read out by an 8 X 8 pixel multi-anode photomultiplier and the signal amplitude for each pixel has been recorded for every position on a scan. The pixel signal is strongly dependent on position and in general several pixels will register a signal (a hit) above a given threshold. The effect of this threshold on hit multiplicity is studied, with a view to optimize the single-hit efficiency of the detector.

physics.ins-det

Suppression of intrinsic neutron background in the Multi-Grid detector

One of the key requirements for neutron scattering instruments is the Signal-to-Background ratio (SBR). This is as well a design driving requirement for many instruments at the European Spallation Source (ESS), which aspires to be the brightest neutron source of the world. The SBR can be effectively improved with background reduction. The Multi-Grid, a large-area thermal neutron detector with a solid boron carbide converter, is a novel solution for chopper spectrometers. This detector will be installed for the three prospective chopper spectrometers at the ESS. As the Multi-Grid detector is a large area detector with a complex structure, its intrinsic background and its suppression via advanced shielding design should be investigated in its complexity, as it cannot be naively calculated. The intrinsic scattered neutron background and its effect on the SBR is determined via a detailed Monte Carlo simulation for the Multi-Grid detector module, designed for the CSPEC instrument at the ESS. The impact of the detector vessel and the neutron entrance window on scattering is determined, revealing the importance of an optimised internal detector shielding. The background-reducing capacity of common shielding geometries, like side-shielding and end-shielding is determined by using perfect absorber as shielding material, and common shielding materials, like B$_{4}$C and Cd are also tested. On the basis of the comparison of the effectiveness of the different shielding topologies and materials, recommendations are given for a combined shielding of the Multi-Grid detector module, optimised for increased SBR.

physics.ins-det

Scattered neutron background in thermal neutron detectors

Inelastic neutron scattering instruments require very low background; therefore the proper shielding for suppressing the scattered neutron background, both from elastic and inelastic scattering is essential. The detailed understanding of the background scattering sources is required for effective suppression. The Multi-Grid thermal neutron detector is an Ar/CO$_{2}$ gas filled detector with a $^{10}$B$_{4}$C neutron converter coated on aluminium substrates. It is a large-area detector design that will equip inelastic neutron spectrometers at the European Spallation Source (ESS). To this end a parameterised Geant4 model is built for the Multi-Grid detector. This is the first time thermal neutron scattering background sources have been modelled in a detailed simulation of detector response. The model is validated via comparison with measured data of prototypes installed on the IN6 instrument at ILL and on the CNCS instrument at SNS. The effect of scattering originating in detector components is smaller than effects originating elsewhere.

physics.ins-det