SearcharxivSearch

arXiv subjects

K. Kirch

Publications and source records attributed to K. Kirch.

At least 19 recordsLinked to original sources

Laboratory constraints on peV-scale mass splitting between ordinary and sterile neutron states

Sterile states of matter, represented by a parallel ``mirror'' sector, may contribute to the observed dark matter in the Universe. We investigated the parameter space of neutron $(n)$ to mirror-neutron $(n')$ oscillations, in the case where the two states are not necessarily mass-degenerate, taking into account interactions in the mirror sector. By tuning the magnitude of an applied magnetic-field in the range $5~\mu\mathrm{T} < B < 360~\mu\mathrm{T}$ to corresponding resonance conditions for finite mass splitting, we derive exclusion limits for the $n-n'$ oscillation time constant reaching about $20~\text{s}$ over the mass-difference range $0.3 - 22~\text{peV}$. In parts of this parameter range, our limits exceed the model-dependent neutron-star-cooling bound, providing the first experimental constraints in this scenario that are more stringent than this astrophysical estimate.

hep-ex

Charge radii of Cl isotopes from x-ray spectroscopy of muonic atoms

Nuclear charge radii are vital for nuclear and atomic physics, the determination of fundamental constants, and searches for new physics. Muonic atoms, where a single negative muon orbits a nucleus, are sensitive tools for determining nuclear radii due to the large wavefunction overlap of the muon and nucleus. Here we report on a new measurement of the $2, 3, 4p\to1s$ x-ray energies in muonic $^{35,37}$Cl with uncertainties reaching 18 ppm. By employing a large-scale germanium detector array, it was possible to extract these energies from a high statistics dataset using highly enriched samples of only a few tens of milligrams. Combining these results with state-of-the-art atomic and nuclear theory input, the charge radii of the stable chlorine isotopes were determined to be $R(^{35}\text{Cl}) = 3.3333(23)~fm$ and $R(^{37}\text{Cl}) = 3.3444(23)~fm$. This is an order of magnitude more precise and significantly different from previously tabulated values. Our new values solve a discrepancy observed for the charge radius difference in mirror nuclei, agreeing with the overall global trend. The charge radius difference $\delta \langle r^2 \rangle (^{37}\text{Cl} - {^{35}\text{Cl}}) = -0.0776(64)~fm^2$ we extract is 25 times more precise than the previous values. This precision is crucial for establishing reference values for future laser spectroscopy measurements of radioactive isotopes.

nucl-ex

New high-sensitivity search for neutron to mirror-neutron oscillations at the PSI UCN source

In a search for potential signals of neutron (n) to mirror-neutron (n') oscillations, a collaboration centered at the Paul Scherrer Institute (PSI) investigated the remaining parameter space claimed by anomalies with a dedicated high-sensitivity apparatus. An elaborate magnetic-field-mapping analysis and Monte Carlo simulation of the cumulative n-n' oscillation probabilities along the neutron trajectories inside the storage vessel complemented the neutron data analysis. Magnetic fields were scanned in the range 5 microT < B < 109 microT. No evidence of anomalous neutron losses was found. Consequently, new limits for the n-n' oscillation time constant were set. The parameter space, previously claimed for potential signals, has been excluded to 99.98 %.

nucl-ex

Simulation and optimization of the Active Magnetic Shield of the n2EDM experiment

The n2EDM experiment at the Paul Scherrer Institute aims to conduct a high-sensitivity search for the electric dipole moment of the neutron. Magnetic stability and control are achieved through a combination of passive shielding, provided by a magnetically shielded room (MSR), and a surrounding active field compensation system by an Active Magnetic Shield (AMS). The AMS is a feedback-controlled system of eight coils spanned on an irregular grid, designed to provide magnetic stability to the enclosed volume by actively suppressing external magnetic disturbances. It can compensate static and variable magnetic fields up to $\pm 50$ $\mu$T (homogeneous components) and $\pm 5$ $\mu$T/m (first-order gradients), suppressing them to a few $\mu$T in the sub-Hertz frequency range. We present a full finite element simulation of magnetic fields generated by the AMS in the presence of the MSR. This simulation is of sufficient accuracy to approach our measurements. We demonstrate how the simulation can be used with an example, obtaining an optimal number and placement of feedback sensors using genetic algorithms.

physics.ins-det

Measurement of the neutron incoherent scattering length of ${}^{199}$Hg using stored ultracold neutrons

We present the first direct measurement of the neutron incoherent scattering length of ${}^{199}$Hg. The measurement was performed with the Ramsey apparatus of the neutron electric dipole moment experiment located at the Paul Scherrer Institute. The incoherent scattering length $b_\textrm{i}$ was determined by investigating the pseudo-magnetic effect due to the strong interaction between the neutron spins and the nuclear spins of mercury atoms. The resulting frequency shift of the neutron Larmor precession frequency was determined for various ${}^{199}$Hg density and polarization values. The obtained value of $b_\textrm{i}= (-16.2 \pm 2.0)\,$fm agrees in magnitude with previous determinations and provides the so-far unknown sign of the quantity.

nucl-ex

Ultracold neutron energy spectrum and storage properties from magnetically induced spin depolarization

We present a novel method for extracting the energy spectrum of ultracold neutrons from magnetically induced spin depolarization measurements using the n2EDM apparatus. This method is also sensitive to the storage properties of the materials used to trap ultracold neutrons, specifically, whether collisions are specular or diffuse. We highlight the sensitivity of this new technique by comparing the two different storage chambers of the n2EDM experiment. We validate the extraction by comparing to an independent measurement for how this energy spectrum is polarized through a magnetic-filter, and finally, we calculate the neutron center-of-mass offset, an important systematic effect for measurements of the neutron electric dipole moment.

hep-ex

Laser Excitation of Muonic 1S Hydrogen Hyperfine Transition: Effects of Multi-pass Cell Interference

Calculating the laser-induced transition probability by using the fluence distribution that neglects interference effects (e.g., by employing ray-tracing methods) can lead to an overestimation of this probability, as it underestimates saturation effects. In this paper, we investigate how interference effects in the multi-pass cell, used to enhance the laser fluence, affect the laser-induced transition probability between hyperfine levels in muonic hydrogen, a bound system of a negative muon and a proton. To avoid complications related to the exact knowledge of the intra-cavity field, we develop a simple model that estimates the maximal possible interference effects for given laser and multi-pass cell parameters, thereby providing an upper bound for the resulting decrease in transition probability relative to the case where these effects are neglected. A numerical evaluation of this upper bound for muonic hydrogen shows that, under our experimental conditions, such effects can be safely neglected. Nonetheless, the methodology presented here could be applied to estimate the impact of interference effects on the laser-induced transition probability in other experiments involving coherent light in multi-pass systems.

physics.atom-ph

Modern approach to muonic x-ray spectroscopy demonstrated through the measurement of stable Cl radii

Recent advances in muonic x-ray experiments have reinvigorated efforts in measurements of absolute nuclear charge radii. Here, a modern approach is presented, and demonstrated through determination of the charge radii of the two stable chlorine nuclides $^{35}$Cl and $^{37}$Cl. Knowledge of these radii has implications for fundamental studies in nuclear and atomic physics. For this purpose, a state-of-the-art experiment was performed at the $\pi$E1 beamline in the Paul Scherrer Institute (Switzerland), using a large-scale HPGe detector array in order to extract precise energies of the muonic $^{35}$Cl and $^{37}$Cl $np1s$ transitions. The nuclear charge radius extraction relies on modern calculations for QED effects and nuclear polarization with rigorous uncertainty quantification, including effects that were not accounted for in older studies. Additionally, we established a new method for applying the nuclear shape correction directly from energy density functionals, which are amenable to isotopes for which no high-quality electron scattering experiments are available. The resulting charge radii are $3.3335(23) fm$ for $^{35}$Cl and $3.3445(23) fm$ for $^{37}$Cl, thus improving the uncertainty of the available electron scattering values by a factor of seven. The correlation of several observables was evaluated between the different isotopes in order to produce a more precise value of the differential mean square charge radius $\delta \langle r^2 \rangle^{37, 35}=+0.0771(66) fm^{2}$. In this case, improvement of the uncertainty by more than one order of magnitude was achieved compared to the literature value. This precision is sufficient to use this differential as input for isotope shift factor determination.

nucl-ex

A compact frozen-spin trap for the search for the electric dipole moment of the muon

The electric dipole moments~(EDM) of fundamental particles inherently violate parity~(P) and time-reversal~(T) symmetries. By virtue of the CPT theorem in quantum field theory, the latter also implies the violation of the combined charge-conjugation and parity~(CP) symmetry. We aim to measure the EDM of the muon using the frozen-spin technique within a compact storage trap. This method exploits the high effective electric field, \$E \approx 165\$ MV/m, experienced in the rest frame of the muon with a momentum of about 23 MeV/c when it passes through a solenoidal magnetic field of \$|\vec{B}|=2.5\$ T. In this paper, we outline the fundamental considerations for a muon EDM search and present a conceptual design for a demonstration experiment to be conducted at secondary muon beamlines of the Paul Scherrer Institute in Switzerland. In Phase~I, with an anticipated data acquisition period of 200 days, the expected sensitivity to a muon EDM is 4E-21 ecm. In a subsequent phase, Phase~II, we propose to improve the sensitivity to 6E-23 ecm using a dedicated instrument installed on a different beamline that produces muons of momentum 125 MeV/c}.

hep-ex

Phase space compression of a positive muon beam in two spatial dimensions

We present the first demonstration of simultaneous phase space compression in two spatial dimensions of a positive muon beam, the first stage of the novel high-brightness muon beam under development by the muCool collaboration at the Paul Scherrer Institute. The keV-energy, sub-mm size beam would enable a factor 10$^5$ improvement in brightness for precision muSR, and atomic and particle physics measurements with positive muons. This compression is achieved within a cryogenic helium gas target with a strong density gradient, placed in a homogeneous magnetic field, under the influence of a complex electric field. In the next phase, the muon beam will be extracted into vacuum.

physics.acc-ph

Generating a highly uniform magnetic field inside the magnetically shielded room of the n2EDM experiment

We present a coil system designed to generate a highly uniform magnetic field for the n2EDM experiment at the Paul Scherrer Institute. It consists of a main $B_0$ coil and a set of auxiliary coils mounted on a cubic structure with a side length of 273 cm, inside a large magnetically shielded room (MSR). We have assembled this system and characerized its performances with a mapping robot. The apparatus is able to generate a 1 $\mu$ T vertical field with a relative root mean square deviation $\sigma$ ($B_z$)/$B_z$ = 3 $\times$ $10^{-5}$ over the volume of interest, a cylinder of radius 40 cm and height 30 cm. This level of uniformity overcomes the n2EDM requirements, allowing a measurement of the neutron Electric Dipole Moment with a sensitivity better than 1 $\times$ $10^{-27}$ ecm.

physics.ins-det

Temperature dependent ultracold neutron transmission in D$_2$ gas $-$ a test of the Young-Koppel model

The Young-Koppel model (YK) describes comprehensively the interaction of slow neutrons with diatomic gases such as H$_2$ and D$_2$. This paper reports on the first experimental results of ultracold neutron (UCN) scattering over a wide temperature range vindicating the YK model for gaseous D$_2$ and showing an important difference in the temperature dependence to a low-energy low-temperature approximation (LETA). LETA is confirmed, however, to be valid for monoatomic gases such as Ne. Calculated cross sections for other noble gases were also confirmed for ultracold neutrons. Finally, the total cross section of UCNs in H$_2$ gas was measured and analyzed applying the Young-Koppel model, however, in a more limited temperature range, confirming the theoretical prediction.

nucl-ex

Anomalous spin precession systematic effects in the search for a muon EDM using the frozen-spin technique

At the Paul Scherrer Institut (PSI), we are currently working on the development of a high-precision apparatus with the aim of searching for the muon electric dipole moment (EDM) with unprecedented sensitivity. The underpinning principle of this experiment is the frozen-spin technique, a method that suppresses the spin precession due to the anomalous magnetic moment, thereby enhancing the signal-to-noise ratio for EDM signals. This increased sensitivity facilitates measurements that would be difficult to achieve with conventional $g - 2$ muon storage rings. Given the availability of the $p = 125$ MeV/$c$ muon beam at PSI, the anticipated statistical sensitivity for the EDM after a year of data collection is $6\times 10^{-23}e\cdot$cm. To achieve this goal, it is imperative to meticulously analyse and mitigate any potential spurious effects that could mimic EDM signals. In this study, we present a quantitative methodology to evaluate the systematic effects that might arise in the context of employing the frozen-spin technique within a compact storage ring. Our approach entails the analytical derivation of equations governing the motion of the muon spin in the electromagnetic (EM) fields intrinsic to the experimental setup, validated through subsequent numerical simulations. We also illustrate a method to calculate the cumulative geometric (Berry's) phase. This work complements ongoing experimental efforts to detect a muon EDM at PSI and contributes to a broader understanding of spin-precession systematic effects.

hep-ex

Achieving ultra-low and -uniform residual magnetic fields in a very large magnetically shielded room for fundamental physics experiments

High-precision searches for an electric dipole moment of the neutron (nEDM) require stable and uniform magnetic field environments. We present the recent achievements of degaussing and equilibrating the magnetically shielded room (MSR) for the n2EDM experiment at the Paul Scherrer Institute. We present the final degaussing configuration that will be used for n2EDM after numerous studies. The optimized procedure results in a residual magnetic field that has been reduced by a factor of two. The ultra-low field is achieved with the full magnetic-field-coil system, and a large vacuum vessel installed, both in the MSR. In the inner volume of ~1.4 m^3, the field is now more uniform and below 300 pT. In addition, the procedure is faster and dissipates less heat into the magnetic environment, which in turn, reduces its thermal relaxation time from 12 h down to ~1.5 h.

physics.ins-det

A large 'Active Magnetic Shield' for a high-precision experiment

We present a novel Active Magnetic Shield (AMS), designed and implemented for the n2EDM experiment at the Paul Scherrer Institute. The experiment will perform a high-sensitivity search for the electric dipole moment of the neutron. Magnetic-field stability and control is of key importance for n2EDM. A large, cubic, 5m side length, magnetically shielded room (MSR) provides a passive, quasi-static shielding-factor of about 10^5 for its inner sensitive volume. The AMS consists of a system of eight complex, feedback-controlled compensation coils constructed on an irregular grid spanned on a volume of less than 1000m^3 around the MSR. The AMS is designed to provide a stable and uniform magnetic-field environment around the MSR, while being reasonably compact. The system can compensate static and variable magnetic fields up to +-50muT (homogeneous components) and +-5muT (first-order gradients), suppressing them to a few muT in the sub-Hertz frequency range. The presented design concept and implementation of the AMS fulfills the requirements of the n2EDM experiment and can be useful for other applications, where magnetically silent environments are important and spatial constraints inhibit simpler geometrical solutions.

physics.ins-det

Search for an interaction mediated by axion-like particles with ultracold neutrons at the PSI

We report on a search for a new, short-range, spin-dependent interaction using a modified version of the experimental apparatus used to measure the permanent neutron electric dipole moment at the Paul Scherrer Institute. This interaction, which could be mediated by axion-like particles, concerned the unpolarized nucleons (protons and neutrons) near the material surfaces of the apparatus and polarized ultracold neutrons stored in vacuum. The dominant systematic uncertainty resulting from magnetic-field gradients was controlled to an unprecedented level of approximately 4 pT/cm using an array of optically-pumped cesium vapor magnetometers and magnetic-field maps independently recorded using a dedicated measurement device. No signature of a theoretically predicted new interaction was found, and we set a new limit on the product of the scalar and the pseudoscalar couplings $g_sg_p\lambda^2 < 8.3 \times 10^{-28}\,\text{m}^2$ (95% C.L.) in a range of $5\,\mu\text{m} < \lambda < 25\,\text{mm}$ for the monopole-dipole interaction. This new result confirms and improves our previous limit by a factor of 2.7 and provides the current tightest limit obtained with free neutrons.

nucl-ex

Time-of-flight spectroscopy of ultracold neutrons at the PSI UCN source

The ultracold neutron (UCN) source at the Paul Scherrer Institute (PSI) provides high intensities of storable neutrons for fundamental physics experiments. The neutron velocity spectrum parallel to the beamline axis was determined by time-of-flight spectroscopy using a neutron chopper. In particular, the temporal evolution of the spectrum during neutron production and UCN storage in the source storage volume was investigated and compared to Monte Carlo simulation results. A softening of the measured spectrum from a mean velocity of 7.7(1) m s$^{-1}$ to 5.1(1) m s$^{-1}$ occurred within the first 30 s after the proton beam pulse had impinged on the spallation target. A spectral hardening was observed over longer time scales of one measurement day, consistent with the effect of surface degradation of the solid deuterium moderator.

physics.ins-det

In-situ measurement of the velocity spectrum of ultracold neutrons and its evolution using an oscillating detector

Ultracold neutrons (UCNs) are used in experiments investigating fundamental interactions, testing the Standard Model of particle physics and searching for phenomena beyond it. Knowledge of the energy spectrum of UCNs is very often a key ingredient to determine the systematic effects in precision measurements utilizing UCNs. The proposed novel method allows for the in-situ measurements of the UCN velocity distribution and its time evolution. In addition, the proposed UCN spectrometer can be a handy diagnostic tool for monitoring the spectrum in critical places in the UCN transport system connecting an UCN source with experiments. In this paper, we show the results from the measurements performed at the Paul Scherrer Institute's UCN source.

nucl-ex