SearcharxivSearch

arXiv subjects

K. Knoepfel

Publications and source records attributed to K. Knoepfel.

5 recordsLinked to original sources

A Study Of The Energy Dependence Of Radiation Damage In Superconducting Coils For a Next Generation Mu2e At PIP-II

The Mu2e experiment at Fermilab is being designed to study the coherent neutrino-less conversion of a negative muon into an electron in the field of a nucleus. This process has an extremely low probability in the Standard Model, and its observation would provide unambiguous evidence for beyond the standard model physics. The Mu2e design aims to reach a single-event-sensitivity of about $2.5 \times 10^{-17}$ and will probe effective new physics mass scales in the 103-104 TeV range, well beyond the reach of the LHC. This work will examine the maximum beam power that can be tolerated for beam energies in the 0.5-8 GeV range. This has implications for how the sensitivity might be further improved with a second generation experiment using an upgraded proton beam from the PIP-II project, which will be capable of providing MW beams to Fermilab experiments later in the next decade.

physics.acc-ph

Mu2e Technical Design Report

The Mu2e experiment at Fermilab will search for charged lepton flavor violation via the coherent conversion process mu- N --> e- N with a sensitivity approximately four orders of magnitude better than the current world's best limits for this process. The experiment's sensitivity offers discovery potential over a wide array of new physics models and probes mass scales well beyond the reach of the LHC. We describe herein the preliminary design of the proposed Mu2e experiment. This document was created in partial fulfillment of the requirements necessary to obtain DOE CD-2 approval.

physics.ins-det

CDF Run II Silicon Vertex Detector Annealing Study

Between Run II commissioning in early 2001 and the end of operations in September 2011, the Tevatron collider delivered 12~fb$^{-1}$ of $p\bar{p}$ collisions at $\sqrt{s}=1.96$ TeV to the Collider Detector at Fermilab (CDF). During that time, the CDF silicon vertex detector was subject to radiation doses of up to 12 Mrad. After the end of operations, the silicon detector was annealed for 24 days at $18^{\circ}$C. In this paper, we present a measurement of the change in the bias currents for a subset of sensors during the annealing period. We also introduce a novel method for monitoring the depletion voltage throughout the annealing period. The observed bias current evolution can be characterized by a falling exponential term with time constant $τ_I=17.88\pm0.36$(stat.)$\pm0.25$(syst.) days. We observe an average decrease of $(27\pm3)\%$ in the depletion voltage, whose evolution can similarly be described by an exponential time constant of $τ_V=6.21\pm0.21$ days. These results are consistent with the Hamburg model within the measurement uncertainties.

physics.ins-det

Operational experience, improvements, and performance of the CDF Run II silicon vertex detector

The Collider Detector at Fermilab (CDF) pursues a broad physics program at Fermilab's Tevatron collider. Between Run II commissioning in early 2001 and the end of operations in September 2011, the Tevatron delivered 12 fb-1 of integrated luminosity of p-pbar collisions at sqrt(s)=1.96 TeV. Many physics analyses undertaken by CDF require heavy flavor tagging with large charged particle tracking acceptance. To realize these goals, in 2001 CDF installed eight layers of silicon microstrip detectors around its interaction region. These detectors were designed for 2--5 years of operation, radiation doses up to 2 Mrad (0.02 Gy), and were expected to be replaced in 2004. The sensors were not replaced, and the Tevatron run was extended for several years beyond its design, exposing the sensors and electronics to much higher radiation doses than anticipated. In this paper we describe the operational challenges encountered over the past 10 years of running the CDF silicon detectors, the preventive measures undertaken, and the improvements made along the way to ensure their optimal performance for collecting high quality physics data. In addition, we describe the quantities and methods used to monitor radiation damage in the sensors for optimal performance and summarize the detector performance quantities important to CDF's physics program, including vertex resolution, heavy flavor tagging, and silicon vertex trigger performance.

physics.ins-det