Searcharxiv⌕ Search

arXiv subjects

K. L. Giboni

Publications and source records attributed to K. L. Giboni.

26 records · Page 2Linked to original sources

Gamma Ray Spectroscopy with Scintillation Light in Liquid Xenon

Scintillation light from gamma ray irradiation in liquid xenon is detected by two Hamamatsu R9288 photomultiplier tubes (PMTs) immersed in the liquid. UV light reflector material, PTFE, is used to optimize the light collection efficiency. The detector gives a high light yield of 6 photoelectron per keV (pe/keV), which allows efficient detection of the 122 keV gamma-ray line from Co-57, with a measured energy resolution of (8.8+/-0.6)% (sigma). The best achievable energy resolution, by removing the instrumental fluctuations, from liquid xenon scintillation light is estimated to be around 6-8% (sigma) for gamma-ray with energy between 662 keV and 122 keV.

physics.ins-det↗

Simultaneous Measurement of Ionization and Scintillation from Nuclear Recoils in Liquid Xenon as Target for a Dark Matter Experiment

We report the first measurements of the absolute ionization yield of nuclear recoils in liquid xenon, as a function of energy and electric-field. Independent experiments were carried out with two dual-phase time projection chamber prototypes, developed for the XENON Dark Matter project. We find that the charge yield increases with decreasing recoil energy, and exhibits only a weak field dependence. These results are a first demonstration of the capability of dual phase xenon detectors to discriminate between electron and nuclear recoils, a key requirement for a sensitive dark matter search at recoil energies down to 20 keV.

astro-ph↗

Scintillation Response of Liquid Xenon to Low Energy Nuclear Recoils

Liquid Xenon (LXe) is expected to be an excellent target and detector medium to search for dark matter in the form of Weakly Interacting Massive Particles (WIMPs). Knowledge of LXe ionization and scintillation response to low energy nuclear recoils expected from the scattering of WIMPs by Xe nuclei is important for determining the sensitivity of LXe direct detection experiments. Here we report on new measurements of the scintillation yield of Xe recoils with kinetic energy as low as 10 keV. The dependence of the scintillation yield on applied electric field was also measured in the range of 0 to 4 kV/cm. Results are in good agreement with recent theoretical predictions that take into account the effect of biexcitonic collisions in addition to the nuclear quenching effect.

astro-ph↗

Performance of a Large Area Avalanche Photodiode in a Liquid Xenon Ionization and Scintillation Chamber

Scintillation light produced in liquid xenon (LXe) by alpha particles, electrons and gamma-rays was detected with a large area avalanche photodiode (LAAPD) immersed in the liquid. The alpha scintillation yield was measured as a function of applied electric field. We estimate the quantum efficiency of the LAAPD to be 45%. The best energy resolution from the light measurement at zero electric field is 7.5%(sigma) for 976 keV internal conversion electrons from Bi-207 and 2.6%(sigma) for 5.5 MeV alpha particles from Am-241. The detector used for these measurements was also operated as a gridded ionization chamber to measure the charge yield. We confirm that using a LAAPD in LXe does not introduce impurities which inhibit the drifting of free electrons.

physics.ins-det↗

The XENON Dark Matter Search Experiment

The XENON experiment aims at the direct detection of dark matter in the form of WIMPs (Weakly Interacting Massive Particles) via their elastic scattering off Xe nuclei. A fiducial mass of 1000 kg, distributed in ten independent liquid xenon time projection chambers(LXeTPCs) will be used to probe thelowest interaction cross section predicted by SUSY models. The TPCs are operated in dual (liquid/gas) phase, to allow a measurement of nuclear recoils down to 16keV energy, via simultaneous detection of the ionization, through secondary scintillation in the gas, and primary scintillation in the liquid. Thedistinct ratio of primary to secondary scintillation for nuclear recoils from WIMPs (or neutrons), and for electron recoils from background, iskey to the event-by-event discrimination capability of XENON. A dual phase xenon prototype has been realized and is currently being tested, along with otherprototypes dedicated to other measurements relevant to the XENON program. As part of the R&D phase, we will realize and move underground a first XENON module (XENON10) with at least 10 kg fiducial mass to measure the background rejection capability and to optimize the conditions for continuous and stable detector operation underground. We present some of the results from the ongoing R&D and summarize the expected performance of the 10 kg experiment, from MonteCarlo simulations. The main design features of the 100 kg detector unit(XENON100), with which we envisage to make up the 1 tonne sensitive mass ofXENON1T will also be presented.

astro-ph↗

The LXeGRIT Compton Telescope Prototype: Current Status and Future Prospects

LXeGRIT is the first prototype of a novel concept of Compton telescope, based on the complete 3-dimensional reconstruction of the sequence of interactions of individual gamma rays in one position sensitive detector. This balloon-borne telescope consists of an unshielded time projection chamber with an active volume of 400 cm$^2 \times 7$ cm filled with high purity liquid xenon. Four VUV PMTs detect the fast xenon scintillation light signal, providing the event trigger. 124 wires and 4 anodes detect the ionization signals, providing the event spatial coordinates and total energy. In the period 1999 -- 2001, LXeGRIT has been extensively tested both in the laboratory and at balloon altitude, and its response in the MeV region has been thoroughly characterized. Here we summarize some of the results on pre-flight calibration, event reconstruction techniques, and performance during a 27 hour balloon flight on October 4 -- 5. We further present briefly the on-going efforts directed to improve the performance of this prototype towards the requirements for a base module of a next-generation Compton telescope.

astro-ph↗

On the Background Rate in the LXeGRIT Instrument during the 2000 Balloon Flight

LXeGRIT is the first prototype of a novel Compton telescope for MeV gamma-ray astrophysics based on a Liquid Xenon Time Projection Chamber (LXeTPC), sensitive in the energy band of 0.15-10 MeV. In this homogeneous, 3D position sensitive detector, gamma rays with at least two interactions in the sensitive volume of 2800 cm$^{3}$, are imaged as in a standard Compton telescope. Gamma-rays with a single interaction cannot be imaged and constitute a background which can be easily identified and rejected. Charged particles and localized beta-particles background is also easily suppressed based on the TPC localization capability with millimeter resolution. A measurement of the total gamma-ray background rate in near space conditions and the background rejection power of the LXeTPC was a primary goal of the LXeGRIT balloon flight program. We present here a preliminary analysis addressing this question, based on balloon flight data acquired during the Oct 4-5, 2000 LXeGRIT balloon flight from Ft. Sumner, NM. In this long duration (27 hr) balloon experiment, the LXeGRIT TPC was not surrounded by any gamma-ray or charged particle shield. Single site events and charged particles were mostly rejected on-line at the first and second trigger level. The remaining count rate of single-site \g-ray events, at an average atmospheric depth of 3.2 g cm$^{-2}$, is consistent with that expected from atmospheric and diffuse gamma-ray background, taking into account the instrument mass model and response.

astro-ph↗

Compton scattering sequence reconstruction algorithm for the liquid xenon gamma-ray imaging telescope (LXeGRIT)

The Liquid Xenon Gamma-Ray Imaging Telescope (LXeGRIT) is a balloon born experiment sensitive to \g -rays in the energy band of 0.2-20 MeV. The main detector is a time projection chamber filled with high purity liquid xenon (LXeTPC), in which the three-dimensional location and energy deposit of individual \g -ray interactions are accurately measured in one homogeneous volume. To determine the \g -ray initial direction (Compton imaging), as well as to reject background, the correct sequence of interactions has to be determined. Here we report the development and optimization of an algorithm to reconstruct the Compton scattering sequence and show its performance on Monte Carlo events and LXeGRIT data.

astro-ph↗