SearcharxivSearch

arXiv subjects

K. Mishima

Publications and source records attributed to K. Mishima.

At least 19 recordsLinked to original sources

A New High-Intensity Source for Ultracold Neutrons

The TRIUMF UltraCold Advanced Neutron (TUCAN) collaboration has completed a new superthermal source for ultracold neutrons (UCNs) at TRIUMF. It uses neutrons from a spallation target driven by TRIUMF's %520-MeV main cyclotron. Heavy water and liquid deuterium serve as neutron moderators, and inelastic scattering inside superfluid $^4$He at around \qty{1.1}{\kelvin} slows the neutrons down to become ultracold. During commissioning runs with the completed source, including the deuterium moderator, up to $1.47(2)\times 10^7$ UCNs were detected in the experimental area after irradiating the target and accumulating UCNs in the source for \qty{60}{\second}. Up to \qty{6.75(3)e5} UCN/s were detected during continuous operation, more than at any other source in the world.

physics.ins-det

Initial Performance of the TUCAN Magnetically Shielded Room

The TRIUMF Ultracold Advanced Neutron (TUCAN) collaboration has commissioned a large magnetically shielded room to be used for measuring the neutron electric dipole moment (nEDM) to a precision of $10^{-27}~e\mathrm{cm}$. The room is composed of five layers of MuMetal and one layer of copper and sits within the $\lesssim 370~\mu\mathrm{T}$ ambient field produced by the TRIUMF cyclotron. Within this environment, the quasi-static shielding factor was measured to be $3.25(2) \times 10^4$ at $0.01~\mathrm{Hz}$ with an external peak-to-peak perturbation of $2~\mu\mathrm{T}$. Without the large ambient cyclotron field, the shielding factor improves to $3.75(4)\times 10^4$ at the same perturbation amplitude and frequency. After idealization in the cyclotron field, the residual field at the room center was $B = 1.8(2)~\mathrm{nT}$ and the vertical first-order gradient across the central 1~m$^3$ ($dB_{\mathrm{z}}/dz$) was $-279(64)~\mathrm{pT/m}$. With additional improvement to the idealization, and with active compensation, we expect the room to be adequate for a $10^{-27}~e\mathrm{cm}$ nEDM search.

physics.ins-det

Ultracold Neutron Guide-Coating Facility at U.Winnipeg

We report the construction and commissioning of a new ultracold neutron (UCN) guide-coating facility at the University of Winnipeg. The facility employs pulsed laser deposition (PLD) to produce diamond-like carbon (DLC) coatings on cylindrical UCN guides up to 1 m in length with a 200 mm outer diameter. DLC is a promising material for UCN transport and storage due to its high real component of the optical potential, low neutron absorption cross section, and low depolarization probabilities. First coating attempts on a full length aluminum UCN guide and matching blank flange were successfully coated with a carbon film with density of 2.3 g/cm$^3$, corresponding to optical potentials of 200 neV, as measured by X-ray reflectometry (XRR). Coating thicknesses were measured to be 90 nm for the UCN guide and 180 nm for the flange with no evidence of delamination. The implementation of a plasma plume collimator and plasma feed back control via a time of flight in vacuum ion probe produced a film with an XRR measured density of 2.8 g/cm$^3$, corresponding to an optical potential of 240 neV. This 80 nm thick film had poor adhesion to the aluminum tube substrate. These results establish a baseline for the coating facility. Ongoing and future work focuses on improving the diamond content of films and adhesion through plasma plume collimation, TOF ion probe feed back, and pre/post treatment methods with the goal of providing high quality DLC UCN guides for the TUCAN experiment at TRIUMF.

physics.ins-det

Initial results of the TRIUMF ultracold advanced neutron source

We report the first results on ultracold neutron production from a new spallation-driven superfluid $^4$He (He-II) source at TRIUMF, which is being prepared for a new, precise measurement of the neutron electric dipole moment. A total of $(9.3 \pm 0.8)\times 10^{5}$ ultracold neutrons were observed at a proton beam current of \SI{37}{\uA}, when the target was irradiated for a period of \SI{60}{\s}. The results are in fair agreement with expectations based on a detailed simulation of neutron transport and ultracold neutron source cryogenics. There is some indication that the new source might not be as limited by the conduction of heat through the He-II as originally expected. The results indicate that the source is likely to make its ultimate production goals, once the liquid deuterium cold moderator system is completed, with the expectation that $5.7\times 10^7$~UCNs would be detected in the same experiment with full liquid levels. This would, for example, correspond to delivery of $1.4\times 10^6$~UCNs delivered to each of two nEDM measurement cells, and a statistical uncertainty of $1\times 10^{-27}~e$cm on the neutron EDM in 280 days of running.

nucl-ex

Neutron EDM Experiment with an Advanced Ultracold Neutron Source at TRIUMF

The TRIUMF Ultracold Advanced Neutron (TUCAN) collaboration has been developing a high-intensity ultracold neutron (UCN) source aimed at searching for the neutron electric dipole moment (EDM) with a sensitivity goal of $10^{-27}\ e{\rm cm}$. This article reports on recent progress in commissioning of the UCN source and in the development of the neutron EDM spectrometer. In its final configuration, the accelerator-driven super-thermal UCN source will enable a neutron EDM experiment with two orders of magnitude improved statistics compared to the current best experiment. Substantial progress in 2024 allowed the collaboration to operate the complete source system, with the exception of the liquid deuterium cold moderator, resulting in the first production of UCNs. The status of the EDM spectrometer is also presented, with emphasis on UCN handling components and magnetic subsystems relevant to field control, shielding, and magnetometry.

physics.ins-det

Cryogenic systems for the TUCAN EDM experiment

The TUCAN (TRIUMF UltraCold Advanced Neutron) Collaboration is completing a new ultracold neutron (UCN) source. The UCN source will deliver UCNs to a neutron electric dipole moment (EDM) experiment. The EDM experiment is projected to be capable of an uncertainty of $1\times 10^{-27}~e$cm, competitive with other planned projects, and a factor of ten more precise than the present world's best. The TUCAN source is based on a UCN production volume of superfluid helium (He-II), held at 1~K, and coupled to a proton-driven spallation target. The production rate in the source is expected to be in excess of $10^7$~UCN/s; since UCN losses can be small in superfluid helium, this should allow us to build up a large number of UCNs. The spallation-driven superfluid helium technology is the principal aspect making the TUCAN project unique. The superfluid production volume was recently cooled, for the first time, and successfully filled with superfluid helium. The design principles of the UCN source are described, along with some of the challenging cryogenic milestones that were recently passed.

physics.ins-det

Improved measurements of neutron lifetime with cold neutron beam at J-PARC

The ``neutron lifetime puzzle'' arises from the discrepancy between neutron lifetime measurements obtained using the beam method, which measures decay products, and the bottle method, which measures the disappearance of neutrons. To resolve this puzzle, we conducted an experiment using a pulsed cold neutron beam at J-PARC. In this experiment, the neutron lifetime is determined from the ratio of neutron decay counts to $^3$He(n,p)$^3$H reactions in a gas detector. This experiment belongs to the beam method but differs from previous experiments that measured protons, as it instead detects electrons, enabling measurements with distinct systematic uncertainties. By enlarging the beam transport system and reducing systematic uncertainties, we achieved a fivefold improvement in precision. Analysis of all acquired data yielded a neutron lifetime of $\tau_{\rm n}=877.2~\pm~1.7_{\rm(stat.)}~^{+4.0}_{-3.6}{}_{\rm (sys.)}$ s. This result is consistent with bottle method measurements but exhibits a 2.3$\sigma$ tension with the average value obtained from the proton-detection-based beam method.

nucl-ex

Performance of the Fully-equipped Spin Flip Chopper For Neutron Lifetime Experiment at J-PARC

To solve the ''neutron lifetime puzzle,'' where measured neutron lifetimes differ depending on the measurement methods, an experiment with pulsed neutron beam at J-PARC is in progress. In this experiment, neutrons are bunched into 40-cm lengths using a spin flip chopper (SFC), where the statistical sensitivity was limited by the aperture size of the SFC. The SFC comprises three sets of magnetic supermirrors and two resonant spin flippers. In this paper, we discuss an upgrade to enlarge the apertures of the SFC. With this upgrade, the statistics per unit time of the neutron lifetime experiment increased by a factor of 2.8, while maintaining a signal-to-noise ratio of 250-400 comparable to the previous one. Consequently, the time required to reach a precision of 1 s in the neutron lifetime experiment was reduced from 590 to 170 days, which is a significant reduction in time. This improvement in statistic will also contribute to the reduction of systematic uncertainties, such as background evaluation, fostering further advancements in the neutron lifetime experiments at J-PARC.

physics.ins-det

A diffuse scattering model of ultracold neutrons on wavy surfaces

Metal tubes plated with nickel-phosphorus are used in many fundamental physics experiments using ultracold neutrons (UCN) because of their ease of fabrication. These tubes are usually polished to a average roughness of 25-150 nm. However, there is no scattering model that accurately describes UCN scattering on such a rough guide surface with a mean-square roughness larger than 5 nm. We therefore developed a scattering model for UCN in which scattering from random surface waviness with a size larger than the UCN wavelength is described by a microfacet Bidirectional Reflectance Distribution Function model (mf-BRDF model), and scattering from smaller structures by the Lambert's cosine law (Lambert model). For the surface waviness, we used the statistical distribution of surface slope measured by an atomic force microscope on a sample piece of guide tube as input of the model. This model was used to describe UCN transmission experiments conducted at the pulsed UCN source at J-PARC. In these experiments, a UCN beam collimated to a divergence angle smaller than $\pm 6^{\circ}$ was directed into a guide tube with a mean-square roughness of 6.4 nm to 17 nm at an oblique angle, and the UCN transport performance and its time-of-flight distribution were measured while changing the angle of incidence. The mf-BRDF model combined with the Lambert model with scattering probability $p_{L} = 0.039\pm0.003$ reproduced the experimental results well. We have thus established a procedure to evaluate the characteristics of UCN guide tubes with a surface roughness of approximately 10 nm.

physics.ins-det

Characterization of electroless nickel-phosphorus plating for ultracold-neutron storage

Electroless nickel plating is an established industrial process that provides a robust and relatively low-cost coating suitable for transporting and storing ultracold neutrons (UCN). Using roughness measurements and UCN-storage experiments we characterized UCN guides made from polished aluminum or stainless-steel tubes plated by several vendors. All electroless nickel platings were similarly suited for UCN storage with an average loss probability per wall bounce of $2.8\cdot10^{-4}$ to $4.1\cdot10^{-4}$ for energies between 90 neV and 190 neV, or a ratio of imaginary to real Fermi potential $\eta$ of $1.7\cdot10^{-4}$ to $3.3\cdot10^{-4}$. Measurements at different elevations indicate that the energy dependence of UCN losses is well described by the imaginary Fermi potential. Some special considerations are required to avoid an increase in surface roughness during the plating process and hence a reduction in UCN transmission. Increased roughness had only a minor impact on storage properties. Based on these findings we chose a vendor to plate the UCN-production vessel that will contain the superfluid-helium converter for the new TRIUMF UltraCold Advanced Neutron (TUCAN) source, achieving acceptable UCN-storage properties with ${\eta=3.5(5)\cdot10^{-4}}$.

nucl-ex

Precise Neutron Lifetime Measurement Using Pulsed Neutron Beams at J-PARC

A neutron decays into a proton, an electron, and an anti-neutrino through the beta-decay process. The decay lifetime ($\sim$880 s) is an important parameter in the weak interaction. For example, the neutron lifetime is a parameter used to determine the |$V_{\rm ud}$| parameter of the CKM quark mixing matrix. The lifetime is also one of the input parameters for the Big Bang Nucleosynthesis, which predicts light element synthesis in the early universe. However, experimental measurements of the neutron lifetime today are significantly different (8.4 s or 4.0$\sigma$) depending on the methods. One is a bottle method measuring surviving neutron in the neutron storage bottle. The other is a beam method measuring neutron beam flux and neutron decay rate in the detector. There is a discussion that the discrepancy comes from unconsidered systematic error or undetectable decay mode, such as dark decay. A new type of beam experiment is performed at the BL05 MLF J-PARC. This experiment measured neutron flux and decay rate simultaneously with a time projection chamber using a pulsed neutron beam. We will present the world situation of neutron lifetime and the latest results at J-PARC.

hep-ex

Measurement of $\gamma$ rays from $^6$LiF tile as an inner wall of a neutron-decay detector

A neutron lifetime measurement conducted at the Japan Proton Accelerator Research Complex (J-PARC) is counting the number of electrons from neutron decays with a time projection chamber (TPC). The $\gamma$ rays produced in the TPC cause irreducible background events. To achieve the precise measurement, the inner walls of the TPC consist of $^6$Li-enriched lithium-fluoride ($^6$LiF) tiles to suppress the amount of $\gamma$ rays. In order to estimate the amount of $\gamma$ rays from the $^{6}{\rm LiF}$ tile, prompt gamma ray analysis (PGA) measurements were performed using germanium detectors. We reconstructed the measured $\gamma$-ray energy spectrum using a Monte Carlo simulation with the stripping method. Comparing the measured spectrum with a simulated one, the number of $\gamma$ rays emitted from the$^{6}{\rm LiF}$ tile was $(2.3^{+0.7}_{-0.3}) \times 10^{-4}$ per incident neutron. This is $1.4^{+0.5}_{-0.2}$ times the value assumed for a mole fraction of the $^{6}{\rm LiF}$ tile. We concluded that the amount of $\gamma$ rays produced from the $^{6}{\rm LiF}$ tile is not more twice the originally assumed value.

physics.ins-det

Neutron lifetime measurement with pulsed cold neutrons

The neutron lifetime has been measured by comparing the decay rate with the reaction rate of $^3$He nuclei of a pulsed neutron beam from the spallation neutron source at the Japan Proton Accelerator Research Complex (J-PARC). The decay rate and the reaction rate were determined by simultaneously detecting electrons from the neutron decay and protons from the $^3$He(n,p)$^3$H reaction using a gas chamber of which working gas contains diluted $^3$He. The measured neutron lifetime was $898\,\pm\,10\,_{\rm stat}\,^{+15}_{-18}\,_{\rm sys}\,$s.

hep-ex

Optimizing neutron moderators for a spallation-driven ultracold-neutron source at TRIUMF

We report on our efforts to optimize the geometry of neutron moderators and converters for the TRIUMF UltraCold Advanced Neutron (TUCAN) source using MCNP simulations. It will use an existing spallation neutron source driven by a 19.3 kW proton beam delivered by TRIUMF's 520 MeV cyclotron. Spallation neutrons will be moderated in heavy water at room temperature and in liquid deuterium at 20 K, and then superthermally converted to ultracold neutrons in superfluid, isotopically purified $^4$He. The helium will be cooled by a $^3$He fridge through a $^3$He-$^4$He heat exchanger. The optimization took into account a range of engineering and safety requirements and guided the detailed design of the source. The predicted ultracold-neutron density delivered to a typical experiment is maximized for a production volume of 27 L, achieving a production rate of $1.4 \cdot 10^7$ s$^{-1}$ to $1.6 \cdot 10^7$ s$^{-1}$ with a heat load of 8.1 W. At that heat load, the fridge can cool the superfluid helium to 1.1 K, resulting in a storage lifetime for ultracold neutrons in the source of about 30 s. The most critical performance parameters are the choice of cold moderator and the volume, thickness, and material of the vessel containing the superfluid helium. The source is scheduled to be installed in 2021 and will enable the TUCAN collaboration to measure the electric dipole moment of the neutron with a sensitivity of $10^{-27}$ e cm.

physics.ins-det

Improved determination of thermal cross section of 14N(n,p)14C for the neutron lifetime measurement

In a neutron lifetime measurement at the Japan Proton Accelerator Complex, the neutron lifetime is calculated by the neutron decay rate and the incident neutron flux. The flux is obtained due to counting the protons emitted from the neutron absorption reaction of ${}^{3}{\rm He}$ gas, which is diluted in a mixture of working gas in a detector. Hence, it is crucial to determine the amount of ${}^{3}{\rm He}$ in the mixture. In order to improve the accuracy of the number density of the ${}^{3}{\rm He}$ nuclei, we suggested to use the ${}^{14}{\rm N}({\rm n},{\rm p}){}^{14}{\rm C}$ reaction as a reference because this reaction involves similar kinetic energy as the ${}^{3}{\rm He}({\rm n},{\rm p}){}^{3}{\rm H}$ reaction and a smaller reaction cross section to introduce reasonable large partial pressure. The uncertainty of the recommended value of the cross section, however, is not satisfied with our requirement. In this paper, we report the most accurate experimental value of the cross section of the ${}^{14}{\rm N}({\rm n},{\rm p}){}^{14}{\rm C}$ reaction at a neutron velocity of 2200 m/s, measured relative to the ${}^{3}{\rm He}({\rm n},{\rm p}){}^{3}{\rm H}$ reaction. The result was 1.868 $\pm$ 0.003 (stat.) $\pm$ 0.006 (sys.) b. Additionally, the cross section of the ${}^{17}{\rm O}({\rm n},{\rm α}){}^{14}{\rm C}$ reaction at the neutron velocity is also redetermined as 249 $\pm$ 6 mb.

nucl-ex

First ultracold neutrons produced at TRIUMF

We installed a source for ultracold neutrons at a new, dedicated spallation target at TRIUMF. The source was originally developed in Japan and uses a superfluid-helium converter cooled to 0.9$\,$K. During an extensive test campaign in November 2017, we extracted up to 325000 ultracold neutrons after a one-minute irradiation of the target, over three times more than previously achieved with this source. The corresponding ultracold-neutron density in the whole production and guide volume is 5.3$\,$cm$^{-3}$. The storage lifetime of ultracold neutrons in the source was initially 37$\,$s and dropped to 24$\,$s during the eighteen days of operation. During continuous irradiation of the spallation target, we were able to detect a sustained ultracold-neutron rate of up to 1500$\,$s$^{-1}$. Simulations of UCN production, UCN transport, temperature-dependent UCN yield, and temperature-dependent storage lifetime show excellent agreement with the experimental data and confirm that the ultracold-neutron-upscattering rate in superfluid helium is proportional to $T^7$.

physics.ins-det

A Cold/Ultracold Neutron Detector using Fine-grained Nuclear Emulsion with Spatial Resolution less than 100 nm

A new type of cold/ultracold neutron detector that can realize a spatial resolution of less than 100 nm was developed using nuclear emulsion. The detector consists of a fine-grained nuclear emulsion coating and a 50-nm thick $^{10}$B$_4$C layer for the neutron conversion. The detector was exposed to cold and ultracold neutrons (UCNs) at the J-PARC. Detection efficiencies were measured as (0.16$\pm$0.02)% and (12$\pm$2)% for cold and ultracold neutrons consistently with the $^{10}$B content in the converter. Positions of individual neutrons can be determined by observing secondary particle tracks recorded in the nuclear emulsion. The spatial resolution of incident neutrons were found to be in the range of 11-99 nm in the angle region of tan$θ\leq 1.9$, where $θ$ is the angle between a recorded track and the normal direction of the converter layer. The achieved spatial resolution corresponds to the improvement of one or two orders of magnitude compared with conventional techniques and it is comparable with the wavelength of UCNs.

physics.ins-det