SearcharxivSearch

arXiv subjects

K. Paraschou

Publications and source records attributed to K. Paraschou.

11 recordsLinked to original sources

Xsuite: an integrated beam physics simulation framework

Xsuite is a newly developed modular simulation package combining in a single flexible and modern framework the capabilities of different tools developed at CERN in the past decades, notably Sixtrack, Sixtracklib, COMBI and PyHEADTAIL. The suite consists of a set of Python modules (Xobjects, Xpart, Xtrack, Xcoll, Xfields, Xdeps) that can be flexibly combined together and with other accelerator-specific and general-purpose python tools to study complex simulation scenarios. The code allows for symplectic modeling of the particle dynamics, combined with the effect of synchrotron radiation, impedances, feedbacks, space charge, electron cloud, beam-beam, beamstrahlung, and electron lenses. For collimation studies, beam-matter interaction is simulated using the K2 scattering model or interfacing Xsuite with the BDSIM/Geant4 library. Tools are available to compute the accelerator optics functions from the tracking model and to generate particle distributions matched to the optics. Different computing platforms are supported, including conventional CPUs, as well as GPUs from different vendors.

physics.acc-ph

Precise timing and recent advancements with segmented anode PICOSEC Micromegas prototypes

Timing information in current and future accelerator facilities is important for resolving objects (particle tracks, showers, etc.) in extreme large particles multiplicities on the detection systems. The PICOSEC Micromegas detector has demonstrated the ability to time 150\,GeV muons with a sub-25\,ps precision. Driven by detailed simulation studies and a phenomenological model which describes stochastically the dynamics of the signal formation, new PICOSEC designs were developed that significantly improve the timing performance of the detector. PICOSEC prototypes with reduced drift gap size ($\sim$\SI{119}{\micro\metre}) achieved a resolution of 45\,ps in timing single photons in laser beam tests (in comparison to 76\,ps of the standard PICOSEC detector). Towards large area detectors, multi-pad PICOSEC prototypes with segmented anodes has been developed and studied. Extensive tests in particle beams revealed that the multi-pad PICOSEC technology provides also very precise timing, even when the induced signal is shared among several neighbouring pads. Furthermore, new signal processing algorithms have been developed, which can be applied during data acquisition and provide real time, precise timing.

physics.ins-det

Snowmass 2021 White Paper Instrumentation Frontier 05 -- White Paper 1: MPGDs: Recent advances and current R&D

This paper will review the origins, development, and examples of new versions of Micro-Pattern Gas Detectors. The goal for MPGD development was the creation of detectors that could cost-effectively cover large areas while offering excellent position and timing resolution, and the ability to operate at high incident particle rates. The early MPGD developments culminated in the formation of the RD51 collaboration which has become the critical organization for the promotion of MPGDs and all aspects of their production, characterization, simulation, and uses in an expanding array of experimental configurations. For the Snowmass 2021 study, a number of Letters of Interest were received that illustrate ongoing developments and expansion of the use of MPGDs. In this paper, we highlight high precision timing, high rate application, trigger capability expansion of the SRS readout system, and a structure designed for low ion backflow.

physics.ins-det

Timing performance of a multi-pad PICOSEC-Micromegas detector prototype

The multi-pad PICOSEC-Micromegas is an improved detector prototype with a segmented anode, consisting of 19 hexagonal pads. Detailed studies are performed with data collected in a muon beam over four representative pads. We demonstrate that such a device, scalable to a larger area, provides excellent time resolution and detection efficiency. As expected from earlier single-cell device studies, we measure a time resolution of approximately 25 picoseconds for charged particles hitting near the anode pad centers, and up to 30 picoseconds at the pad edges. Here, we study in detail the effect of drift gap thickness non-uniformity on the timing performance and evaluate impact position based corrections to obtain a uniform timing response over the full detector coverage.

physics.ins-det

Modeling the Timing Characteristics of the PICOSEC Micromegas Detector

The PICOSEC Micromegas detector can time the arrival of Minimum Ionizing Particles with a sub-25 ps precision. A very good timing resolution in detecting single photons is also demonstrated in laser beams. The PICOSEC timing resolution is determined mainly by the drift field. The arrival time of the signal and the timing resolution vary with the size of the pulse amplitude. Detailed simulations based on GARFIELD++ reproduce the experimental PICOSEC timing characteristics. This agreement is exploited to identify the microscopic physical variables, which determine the observed timing properties. In these studies, several counter-intuitive observations are made for the behavior of such microscopic variables. In order to gain insight on the main physical mechanisms causing the observed behavior, a phenomenological model is constructed and presented. The model is based on a simple mechanism of "time-gain per interaction" and it employs a statistical description of the avalanche evolution. It describes quantitatively the dynamical and statistical properties of the microscopic quantities, which determine the PICOSEC timing characteristics, in excellent agreement with the simulations. In parallel, it offers phenomenological explanations for the behavior of these microscopic variables. The formulae expressing this model can be used as a tool for fast and reliable predictions, provided that the input parameter values (e.g. drift velocities) are known for the considered operating conditions.

physics.ins-det

Study of the PICOSEC-Micromegas Detector with Test Beam Data and Phenomenological Modelling of its Response

In this work, a part of the Research and Development effort of the PICOSEC detector is presented. The PICOSEC detector is a novel gas-filled detector, based on the Micromegas detector, which has been developed by the RD-51 PICOSEC collaboration. Instead of relying on traditional direct ionization, the PICOSEC detector takes advantage of the prompt timing characteristics of Cherenkov radiation by converting the Cherenkov photons into electrons through the use of a photocathode. The detector has been put into two type of tests where experimental data are collected. One involves a laser beam and a single photoelectron response at CEA-SACLAY, while the other involves a test beam of 150 GeV muons at the CERN SPS H4 secondary beamline, with multiple photoelectrons. The methods employed in the statistical analysis of the detector's timing properties are summarized and in their application an optimal time resolution of 76 ps is achieved for single photoelectrons. A strange dependence of the mean timing on the size of the electron peak is observed, which mimics the behaviour of the "time walk" effect. A simulation of the detector is developed to study the timing properties, which is also the main scope of the thesis. After a detailed investigation, it is found that the electrons in the gaseous mixture move with a different drift velocity before and after the first multiplication, introducing this "time walk" effect, and a phenomenological explanation of this effect is provided. Finally, a maximum likelihood statistical method for the estimation of the mean number of photoelectron extracted per particle is developed and an optimal time resolution of 24 ps is achieved with a mean number of photoelectrons per particle equal to 10.4. In this work, a deep understanding is acquired on a new detector which has brought upon unprecedented results in the field of gas-filled detectors.

physics.ins-det

Precise Charged Particle Timing with the PICOSEC Detector

The experimental requirements in near future accelerators (e.g. High Luminosity-LHC) has stimulated intense interest in development of detectors with high precision timing capabilities. With this as a goal, a new detection concept called PICOSEC, which is based to a "two-stage" MicroMegas detector coupled to a Cherenkov radiator equipped with a photocathode has been developed. Results obtained with this new detector yield a time resolution of 24\,ps for 150\,GeV muons and 76\,ps for single photoelectrons. In this paper we will report on the performance of the PICOSEC in test beams, as well as simulation studies and modelling of its timing characteristics.

physics.ins-det

Improved Search for Solar Chameleons with a GridPix Detector at CAST

We report on a new search for solar chameleons with the CERN Axion Solar Telescope (CAST). A GridPix detector was used to search for soft X-ray photons in the energy range from 200 eV to 10 keV from converted solar chameleons. No signiffcant excess over the expected background has been observed in the data taken in 2014 and 2015. We set an improved limit on the chameleon photon coupling, $β_γ< 5.7\times10^{10}$ for $1<β_\mathrm{m}<10^6$ at 95% C.L. improving our previous results by a factor two and for the first time reaching sensitivity below the solar luminosity bound for tachocline magnetic fields up to $12.5\,\mathrm{T}$.

hep-ex

Charged particle timing at sub-25 picosecond precision: the PICOSEC detection concept

The PICOSEC detection concept consists in a "two-stage" Micromegas detector coupled to a Cherenkov radiator and equipped with a photocathode. A proof of concept has already been tested: a single-photoelectron response of 76 ps has been measured with a femtosecond UV laser at CEA/IRAMIS, while a time resolution of 24 ps with a mean yield of 10.4 photoelectrons has been measured for 150 GeV muons at the CERN SPS H4 secondary line. This work will present the main results of this prototype and the performance of the different detector configurations tested in 2016-18 beam campaigns: readouts (bulk, resistive, multipad) and photocathodes (metallic+CsI, pure metallic, diamond). Finally, the prospects for building a demonstrator based on PICOSEC detection concept for future experiments will be discussed. In particular, the scaling strategies for a large area coverage with a multichannel readout plane, the R\&D on solid converters for building a robust photocathode and the different resistive configurations for a robust readout.

physics.ins-det

PICOSEC: Charged particle timing at sub-25 picosecond precision with a Micromegas based detector

The prospect of pileup induced backgrounds at the High Luminosity LHC (HL-LHC) has stimulated intense interest in developing technologies for charged particle detection with accurate timing at high rates. The required accuracy follows directly from the nominal interaction distribution within a bunch crossing ($σ_z\sim5$ cm, $σ_t\sim170$ ps). A time resolution of the order of 20-30 ps would lead to significant reduction of these backgrounds. With this goal, we present a new detection concept called PICOSEC, which is based on a "two-stage" Micromegas detector coupled to a Cherenkov radiator and equipped with a photocathode. First results obtained with this new detector yield a time resolution of 24 ps for 150 GeV muons, and 76 ps for single photoelectrons.

physics.ins-det

New CAST Limit on the Axion-Photon Interaction

During 2003--2015, the CERN Axion Solar Telescope (CAST) has searched for $a\toγ$ conversion in the 9 T magnetic field of a refurbished LHC test magnet that can be directed toward the Sun. In its final phase of solar axion searches (2013--2015), CAST has returned to evacuated magnet pipes, which is optimal for small axion masses. The absence of a significant signal above background provides a world leading limit of $g_{aγ} < 0.66 \times 10^{-10} {\rm GeV}^{-1}$ (95% C.L.) on the axion-photon coupling strength for $m_a \lesssim 0.02$ eV. Compared with the first vacuum phase (2003--2004), the sensitivity was vastly increased with low-background x-ray detectors and a new x-ray telescope. These innovations also serve as pathfinders for a possible next-generation axion helioscope.

hep-ex