SearcharxivSearch

arXiv subjects

K. Parodi

Publications and source records attributed to K. Parodi.

4 recordsLinked to original sources

Laser-FLASH: radiobiology at high dose, ultra-high dose-rate, single pulse laser-driven proton source

Laser-driven proton sources have long been developed with an eye on their potential for medical application to radiation therapy. These sources are compact, versatile, and show peculiar characteristics such as extreme instantaneous dose rates, short duration and broad energy spectrum. Typical temporal modality of laser-driven irradiation, the so-called fast-fractionation, results from the composition of multiple, temporally separated, ultra-short dose fractions. In this paper we present the use of a high-energy laser system for delivering the target dose in a single nanosecond pulse, for ultra-fast irradiation of biological samples. A transport line composed by two permanent magnet quadrupoles and a scattering system is used to improve the dose profile and to control the delivered dose-per-pulse. A single-shot dosimetry protocol for the broad-spectrum proton source using Monte Carlo simulations was developed. Doses as high as 20Gy could be delivered in a single shot, lasting less than 10ns over a 1.0cm diameter sample holder, at a dose-rate exceeding 10^9 Gy/s. Exploratory application of extreme laser-driven irradiation conditions, falling within the FLASH irradiation protocol, are presented for in vitro and in vivo irradiation. A reduction of radiation-induced oxidative stress in-vitro and radiation-induced developmental damage in vivo were observed, whereas anti-tumoral efficacy was confirmed by cell survival assay.

physics.med-ph

First Tests of the I-BEAT Detector as Primary Monitor for Target Normal Sheath Accelerated Protons

The properties of laser-accelerated ion bunches are demanding and require development of suitable beam diagnostics. In particular, the short and intense particle bunches with a broad energy spectrum emitted in conjunction with a strong electromagnetic pulse (EMP) are challenging for conventional and well established monitoring systems. An approach based on measuring the acoustic signals of particles depositing their energy in water, referred to as ionoacoustics [https://doi.org/10.1118/1.4905047] was recently developed into Ion-Bunch Energy Acoustic Tracing (I-BEAT)\cite{haffa_i-beat:_2019}. I-BEAT allows online detection of single proton bunches while being cost effective and EMP resistant. A simple water phantom equipped with only one ultrasound transducer positioned on the ion axis allows for reconstructing a rather complex energy spectrum that is typical for (manipulated) laser-accelerated ion bunches. To deduce the lateral bunch properties, additional transducers can be added, for example perpendicular to the ion beam axis. This established setup has been adapted for use closely behind the laser target and tested at the PHELIX laser at GSI. The capability of the system to retrieve information about the broad proton spectrum close to the source despite the harsh conditions has been demonstrated. Future improvements are required, most importantly the increase of dynamic range. Nevertheless, I-BEAT holds promise to evolve into an online diagnostic tool particularly suited for laser-driven source development and optimization at high repetition rates.

physics.acc-ph

A novel approach to electron data background treatment in an online wide-angle spectrometer for laser-accelerated ion and electron bunches

Laser-based ion acceleration is driven by electrical fields emerging when target electrons absorb laser energy and consecutively leave the target material. A direct correlation between these electrons and the accelerated ions is thus to be expected and predicted by theoretical models. We report on a modified wide-angle spectrometer allowing the simultaneous characterization of angularly resolved energy distributions of both ions and electrons. Equipped with online pixel detectors, the RadEye1 detectors, the investigation of this correlation gets attainable on a single shot basis. In addition to first insights, we present a novel approach for reliably extracting the primary electron energy distribution from the interfering secondary radiation background. This proves vitally important for quantitative extraction of average electron energies (temperatures) and emitted total charge.

physics.plasm-ph

Sub-millimeter nuclear medical imaging with high sensitivity in positron emission tomography using beta-gamma coincidences

We present a nuclear medical imaging technique, employing triple-gamma trajectory intersections from beta^+ - gamma coincidences, able to reach sub-millimeter spatial resolution in 3 dimensions with a reduced requirement of reconstructed intersections per voxel compared to a conventional PET reconstruction analysis. This '$γ$-PET' technique draws on specific beta^+ - decaying isotopes, simultaneously emitting an additional photon. Exploiting the triple coincidence between the positron annihilation and the third photon, it is possible to separate the reconstructed 'true' events from background. In order to characterize this technique, Monte-Carlo simulations and image reconstructions have been performed. The achievable spatial resolution has been found to reach ca. 0.4 mm (FWHM) in each direction for the visualization of a 22Na point source. Only 40 intersections are sufficient for a reliable sub-millimeter image reconstruction of a point source embedded in a scattering volume of water inside a voxel volume of about 1 mm^3 ('high-resolution mode'). Moreover, starting with an injected activity of 400 MBq for ^76Br, the same number of only about 40 reconstructed intersections are needed in case of a larger voxel volume of 2 x 2 x 3~mm^3 ('high-sensitivity mode'). Requiring such a low number of reconstructed events significantly reduces the required acquisition time for image reconstruction (in the above case to about 140 s) and thus may open up the perspective for a quasi real-time imaging.

physics.med-ph