Searcharxiv⌕ Search

arXiv subjects

K. S. Kumar

Publications and source records attributed to K. S. Kumar.

At least 55 records · Page 3Linked to original sources

VUV-sensitive Silicon Photomultipliers for Xenon Scintillation Light Detection in nEXO

Future tonne-scale liquefied noble gas detectors depend on efficient light detection in the VUV range. In the past years Silicon Photomultipliers (SiPMs) have emerged as a valid alternative to standard photomultiplier tubes or large area avalanche photodiodes. The next generation double beta decay experiment, nEXO, with a 5 tonne liquid xenon time projection chamber, will use SiPMs for detecting the $178\,\text{nm}$ xenon scintillation light, in order to achieve an energy resolution of $σ/ Q_{ββ} = 1\, \%$. This paper presents recent measurements of the VUV-HD generation SiPMs from Fondazione Bruno Kessler in two complementary setups. It includes measurements of the photon detection efficiency with gaseous xenon scintillation light in a vacuum setup and dark measurements in a dry nitrogen gas setup. We report improved photon detection efficiency at $175\,\text{nm}$ compared to previous generation devices, that would meet the criteria of nEXO. Furthermore, we present the projected nEXO detector light collection and energy resolution that could be achieved by using these SiPMs.

physics.ins-det↗

Imaging individual barium atoms in solid xenon for barium tagging in nEXO

The search for neutrinoless double beta decay probes the fundamental properties of neutrinos, including whether or not the neutrino and antineutrino are distinct. Double beta detectors are large and expensive, so background reduction is essential for extracting the highest sensitivity. The identification, or 'tagging', of the $^{136}$Ba daughter atom from double beta decay of $^{136}$Xe provides a technique for eliminating backgrounds in the nEXO neutrinoless double beta decay experiment. The tagging scheme studied in this work utilizes a cryogenic probe to trap the barium atom in solid xenon, where the barium atom is tagged via fluorescence imaging in the solid xenon matrix. Here we demonstrate imaging and counting of individual atoms of barium in solid xenon by scanning a focused laser across a solid xenon matrix deposited on a sapphire window. When the laser sits on an individual atom, the fluorescence persists for $\sim$30~s before dropping abruptly to the background level, a clear confirmation of one-atom imaging. No barium fluorescence persists following evaporation of a barium deposit to a limit of $\leq$0.16\%. This is the first time that single atoms have been imaged in solid noble element. It establishes the basic principle of a barium tagging technique for nEXO.

physics.ins-det↗

Sensitivity and discovery potential of the proposed nEXO experiment to neutrinoless double beta decay

The next-generation Enriched Xenon Observatory (nEXO) is a proposed experiment to search for neutrinoless double beta ($0νββ$) decay in $^{136}$Xe with a target half-life sensitivity of approximately $10^{28}$ years using $5\times10^3$ kg of isotopically enriched liquid-xenon in a time projection chamber. This improvement of two orders of magnitude in sensitivity over current limits is obtained by a significant increase of the $^{136}$Xe mass, the monolithic and homogeneous configuration of the active medium, and the multi-parameter measurements of the interactions enabled by the time projection chamber. The detector concept and anticipated performance are presented based upon demonstrated realizable background rates.

nucl-ex↗

Deep Neural Networks for Energy and Position Reconstruction in EXO-200

We apply deep neural networks (DNN) to data from the EXO-200 experiment. In the studied cases, the DNN is able to reconstruct the relevant parameters - total energy and position - directly from raw digitized waveforms, with minimal exceptions. For the first time, the developed algorithms are evaluated on real detector calibration data. The accuracy of reconstruction either reaches or exceeds what was achieved by the conventional approaches developed by EXO-200 over the course of the experiment. Most existing DNN approaches to event reconstruction and classification in particle physics are trained on Monte Carlo simulated events. Such algorithms are inherently limited by the accuracy of the simulation. We describe a unique approach that, in an experiment such as EXO-200, allows to successfully perform certain reconstruction and analysis tasks by training the network on waveforms from experimental data, either reducing or eliminating the reliance on the Monte Carlo.

physics.ins-det↗

nEXO Pre-Conceptual Design Report

The projected performance and detector configuration of nEXO are described in this pre-Conceptual Design Report (pCDR). nEXO is a tonne-scale neutrinoless double beta ($0νββ$) decay search in $^{136}$Xe, based on the ultra-low background liquid xenon technology validated by EXO-200. With $\simeq$ 5000 kg of xenon enriched to 90% in the isotope 136, nEXO has a projected half-life sensitivity of approximately $10^{28}$ years. This represents an improvement in sensitivity of about two orders of magnitude with respect to current results. Based on the experience gained from EXO-200 and the effectiveness of xenon purification techniques, we expect the background to be dominated by external sources of radiation. The sensitivity increase is, therefore, entirely derived from the increase of active mass in a monolithic and homogeneous detector, along with some technical advances perfected in the course of a dedicated R&D program. Hence the risk which is inherent to the construction of a large, ultra-low background detector is reduced, as the intrinsic radioactive contamination requirements are generally not beyond those demonstrated with the present generation $0νββ$ decay experiments. Indeed, most of the required materials have been already assayed or reasonable estimates of their properties are at hand. The details described herein represent the base design of the detector configuration as of early 2018. Where potential design improvements are possible, alternatives are discussed. This design for nEXO presents a compelling path towards a next generation search for $0νββ$, with a substantial possibility to discover physics beyond the Standard Model.

physics.ins-det↗

Study of Silicon Photomultiplier Performance in External Electric Fields

We report on the performance of silicon photomultiplier (SiPM) light sensors operating in electric field strength up to 30 kV/cm and at a temperature of 149K, relative to their performance in the absence of an external electric field. The SiPM devices used in this study show stable gain, photon detection efficiency, and rates of correlated pulses, when exposed to external fields, within the estimated uncertainties. No observable physical damage to the bulk or surface of the devices was caused by the exposure.

physics.ins-det↗

Multilevel effects in a driven generalized Rabi model

We study numerically the onset of higher-level excitations and resonance frequency shifts in the generalized multilevel Rabi model with dispersive coupling under strong driving. The response to a weak probe is calculated using the Floquet method, which allows us to calculate the probe spectrum and extract the resonance frequency. We test our predictions using a superconducting circuit consisting of transmon coupled capacitively to a coplanar waveguide resonator. This system is monitored by a weak probe field, and at the same time driven at various powers by a stronger microwave tone. We show that the transition from the quantum to the classical regime is accompanied by a rapid increase of the transmon occupation and, consequently that the qubit approximation is valid only in the extreme quantum limit.

cond-mat.mes-hall↗

Study of Light Backgrounds from Relativistic Electrons in Air Light-Guides

The MOLLER experiment proposed at the Thomas Jefferson National Accelerator Facility plans a precision low energy determination of the weak mixing angle via the measurement of the parity-violating asymmetry in the scattering of high energy longitudinally polarized electrons from electrons bound in a liquid hydrogen target (Møller scattering). A relative measure of the scattering rate is planned to be obtained by intercepting the Møller scattered electrons with a circular array of thin fused silica tiles attached to air light guides, which facilitate the transport of Cherenkov photons generated within the tiles to photomultiplier tubes (PMTs). The scattered flux will also pass through the light guides of downstream tiles, generating additional Cherenkov as well as scintillation light and is a potential background. In order to estimate the rate of these backgrounds, a gas-filled tube detector was designed and deployed in an electron beam at the MAMI facility at Johannes Gutenberg University, Mainz, Germany. Described in this paper is the design of a detector to measure separately the scintillation and Cherenkov responses of gas mixtures from relativistic electrons, the results of studies of several gas mixtures with comparisons to simulations, and conclusions about the implications for the design of the MOLLER detector apparatus.

physics.ins-det↗

Search for nucleon decays with EXO-200

A search for instability of nucleons bound in $^{136}$Xe nuclei is reported with 223 kg$\cdot$yr exposure of $^{136}$Xe in the EXO-200 experiment. Lifetime limits of 3.3$\times 10^{23}$ and 1.9$\times 10^{23}$ yrs are established for nucleon decay to $^{133}$Sb and $^{133}$Te, respectively. These are the most stringent to date, exceeding the prior decay limits by a factor of 9 and 7, respectively.

hep-ex↗

Search for Neutrinoless Double-Beta Decay with the Upgraded EXO-200 Detector

Results from a search for neutrinoless double-beta decay $0νββ$ of $^{136}$Xe are presented using the first year of data taken with the upgraded EXO-200 detector. Relative to previous searches by EXO-200, the energy resolution of the detector has been improved to $σ/E$=1.23%, the electric field in the drift region has been raised by 50%, and a system to suppress radon in the volume between the cryostat and lead shielding has been implemented. In addition, analysis techniques that improve topological discrimination between $0νββ$ and background events have been developed. Incorporating these hardware and analysis improvements, the median 90% confidence level $0νββ$ half-life sensitivity after combining with the full data set acquired before the upgrade has increased 2-fold to $3.7 \times 10^{25}$ yr. No statistically significant evidence for $0νββ$ is observed, leading to a lower limit on the $0νββ$ half-life of $1.8\times10^{25}$ yr at the 90% confidence level.

hep-ex↗

Characterization of an Ionization Readout Tile for nEXO

A new design for the anode of a time projection chamber, consisting of a charge-detecting "tile", is investigated for use in large scale liquid xenon detectors. The tile is produced by depositing 60 orthogonal metal charge-collecting strips, 3~mm wide, on a 10~\si{\cm} $\times$ 10~\si{\cm} fused-silica wafer. These charge tiles may be employed by large detectors, such as the proposed tonne-scale nEXO experiment to search for neutrinoless double-beta decay. Modular by design, an array of tiles can cover a sizable area. The width of each strip is small compared to the size of the tile, so a Frisch grid is not required. A grid-less, tiled anode design is beneficial for an experiment such as nEXO, where a wire tensioning support structure and Frisch grid might contribute radioactive backgrounds and would have to be designed to accommodate cycling to cryogenic temperatures. The segmented anode also reduces some degeneracies in signal reconstruction that arise in large-area crossed-wire time projection chambers. A prototype tile was tested in a cell containing liquid xenon. Very good agreement is achieved between the measured ionization spectrum of a $^{207}$Bi source and simulations that include the microphysics of recombination in xenon and a detailed modeling of the electrostatic field of the detector. An energy resolution $σ/E$=5.5\% is observed at 570~\si{keV}, comparable to the best intrinsic ionization-only resolution reported in literature for liquid xenon at 936~V/\si{cm}.

physics.ins-det↗

Searches for Double Beta Decay of $^{134}$Xe with EXO-200

Searches for double beta decay of $^{134}$Xe were performed with EXO-200, a single-phase liquid xenon detector designed to search for neutrinoless double beta decay of $^{136}$Xe. Using an exposure of $29.6\text{ kg}\!\cdot\!\text{yr}$, the lower limits of $\text{T}_{1/2}^{2νβ\!β}>8.7\cdot10^{20}\text{ yr}$ and $\text{T}_{1/2}^{0νβ\!β}>1.1\cdot10^{23}\text{ yr}$ at 90% confidence level were derived, with corresponding half-life sensitivities of $1.2\cdot10^{21}\text{ yr}$ and $1.9\cdot10^{23}\text{ yr}$. These limits exceed those in the literature for $^{134}$Xe, improving by factors of nearly $10^{5}$ and 2 for the two antineutrino and neutrinoless modes, respectively.

hep-ex↗

Observation of the Bloch-Siegert shift in a driven quantum-to-classical transition

We show that the counter-rotating terms of the dispersive qubit-cavity Rabi model can produce relatively large and nonmonotonic Bloch-Siegert shifts in the cavity frequency as the system is driven through a quantum-to-classical transition. Using a weak microwave probe tone, we demonstrate experimentally this effect by monitoring the resonance frequency of a microwave cavity coupled to a transmon and driven by a microwave field with varying power. In the weakly driven regime (quantum phase), the Bloch-Siegert shift appears as a small constant frequency shift, while for strong drive (classical phase) it presents an oscillatory behaviour as a function of the number of photons in the cavity. The experimental results are in agreement with numerical simulations based on the quasienergy spectrum.

cond-mat.mes-hall↗

Measurements of the ion fraction and mobility of alpha and beta decay products in liquid xenon using EXO-200

Alpha decays in the EXO-200 detector are used to measure the fraction of charged $^{218}\mathrm{Po}$ and $^{214}\mathrm{Bi}$ daughters created from alpha and beta decays, respectively. $^{222}\mathrm{Rn}$ alpha decays in liquid xenon (LXe) are found to produce $^{218}\mathrm{Po}^{+}$ ions $50.3 \pm 3.0\%$ of the time, while the remainder of the $^{218}\mathrm{Po}$ atoms are neutral. The fraction of $^{214}\mathrm{Bi}^{+}$ from $^{214}\mathrm{Pb}$ beta decays in LXe is found to be $76.4 \pm 5.7\%$, inferred from the relative rates of $^{218}\mathrm{Po}$ and $^{214}\mathrm{Po}$ alpha decays in the LXe. The average velocity of $^{218}\mathrm{Po}$ ions is observed to decrease for longer drift times. Initially the ions have a mobility of $0.390 \pm 0.006~\mathrm{cm}^2/(\mathrm{kV}~\mathrm{s})$, and at long drift times the mobility is $0.219 \pm 0.004~\mathrm{cm}^2/(\mathrm{kV}~\mathrm{s})$. Time constants associated with the change in mobility during drift of the $^{218}\mathrm{Po}^{+}$ ions are found to be proportional to the electron lifetime in the LXe.

nucl-ex↗

Trace radioactive impurities in final construction materials for EXO-200

We report results from a systematic measurement campaign conducted to identify low radioactivity materials for the construction of the EXO-200 double beta decay experiment. Partial results from this campaign have already been reported in a 2008 paper by the EXO collaboration. Here we release the remaining data, collected since 2007, to the public. The data reported were obtained using a variety of analytic techniques. The measurement sensitivities are among the best in the field. Construction of the EXO-200 detector has been concluded, and Phase-I data was taken from 2011 to 2014. The detector's extremely low background implicitly verifies the measurements and the analysis assumptions made during construction and reported in this paper.

physics.ins-det↗

An apparatus to manipulate and identify individual Ba ions from bulk liquid Xe

We describe a system to transport and identify barium ions produced in liquid xenon, as part of R&D towards the second phase of a double beta decay experiment, nEXO. The goal is to identify the Ba ion resulting from an extremely rare nuclear decay of the isotope $^{136}$Xe, hence providing a confirmation of the occurrence of the decay. This is achieved through Resonance Ionization Spectroscopy (RIS). In the test setup described here, Ba ions can be produced in liquid xenon or vacuum and collected on a clean substrate. This substrate is then removed to an analysis chamber under vacuum, where laser-induced thermal desorption and RIS are used with time-of-flight (TOF) mass spectroscopy for positive identification of the barium decay product.

physics.ins-det↗

An Optimal Energy Estimator to Reduce Correlated Noise for the EXO-200 Light Readout

The energy resolution of the EXO-200 detector is limited by electronics noise in the measurement of the scintillation response. Here we present a new technique to extract optimal scintillation energy measurements for signals split across multiple channels in the presence of correlated noise. The implementation of these techniques improves the energy resolution of the detector at the neutrinoless double beta decay Q-value from $\left[1.9641\pm 0.0039\right]\%$ to $\left[1.5820\pm 0.0044\right]\%$.

physics.ins-det↗

Search for $2νββ$ decay of $^{136}$Xe to the 0$_1^+$ excited state of $^{136}$Ba with EXO-200

EXO-200 is a single phase liquid xenon detector designed to search for neutrinoless double-beta decay of $^{136}$Xe to the ground state of $^{136}$Ba. We report here on a search for the two-neutrino double-beta decay of $^{136}$Xe to the first $0^+$ excited state, $0^+_1$, of $^{136}$Ba based on a 100 kg$\cdot$yr exposure of $^{136}$Xe. Using a specialized analysis employing a machine learning algorithm, we obtain a 90% CL half-life sensitivity of $1.7 \times 10^{24}$ yr. We find no statistically significant evidence for the $2νββ$ decay to the excited state resulting in a lower limit of $T^{2ν}_{1/2}$ ($0^+ \rightarrow 0^+_1$) $> 6.9 \times 10^{23}$ yr at 90% CL. This observed limit is consistent with the estimated half-life of $2.5\times10^{25}$ yr.

nucl-ex↗