SearcharxivSearch

arXiv subjects

K. S. Tanaka

Publications and source records attributed to K. S. Tanaka.

11 recordsLinked to original sources

Laboratory constraints on peV-scale mass splitting between ordinary and sterile neutron states

Sterile states of matter, represented by a parallel ``mirror'' sector, may contribute to the observed dark matter in the Universe. We investigated the parameter space of neutron $(n)$ to mirror-neutron $(n')$ oscillations, in the case where the two states are not necessarily mass-degenerate, taking into account interactions in the mirror sector. By tuning the magnitude of an applied magnetic-field in the range $5~μ\mathrm{T} < B < 360~μ\mathrm{T}$ to corresponding resonance conditions for finite mass splitting, we derive exclusion limits for the $n-n'$ oscillation time constant reaching about $20~\text{s}$ over the mass-difference range $0.3 - 22~\text{peV}$. In parts of this parameter range, our limits exceed the model-dependent neutron-star-cooling bound, providing the first experimental constraints in this scenario that are more stringent than this astrophysical estimate.

hep-ex

New high-sensitivity search for neutron to mirror-neutron oscillations at the PSI UCN source

In a search for potential signals of neutron (n) to mirror-neutron (n') oscillations, a collaboration centered at the Paul Scherrer Institute (PSI) investigated the remaining parameter space claimed by anomalies with a dedicated high-sensitivity apparatus. An elaborate magnetic-field-mapping analysis and Monte Carlo simulation of the cumulative n-n' oscillation probabilities along the neutron trajectories inside the storage vessel complemented the neutron data analysis. Magnetic fields were scanned in the range 5 microT < B < 109 microT. No evidence of anomalous neutron losses was found. Consequently, new limits for the n-n' oscillation time constant were set. The parameter space, previously claimed for potential signals, has been excluded to 99.98 %.

nucl-ex

Ultracold neutron energy spectrum and storage properties from magnetically induced spin depolarization

We present a novel method for extracting the energy spectrum of ultracold neutrons from magnetically induced spin depolarization measurements using the n2EDM apparatus. This method is also sensitive to the storage properties of the materials used to trap ultracold neutrons, specifically, whether collisions are specular or diffuse. We highlight the sensitivity of this new technique by comparing the two different storage chambers of the n2EDM experiment. We validate the extraction by comparing to an independent measurement for how this energy spectrum is polarized through a magnetic-filter, and finally, we calculate the neutron center-of-mass offset, an important systematic effect for measurements of the neutron electric dipole moment.

hep-ex

Revisiting the ARM cut in Compton gamma-ray imaging and its application to the INSPIRE detector

The Compton camera is a gamma-ray imaging device developed in the 1970s. In the 1990s, the COMPTEL detector onboard the CGRO was the first to utilize a Compton camera for MeV all-sky survey observations. Recently, various Compton cameras have been developed using scintillators, semiconductors, and gas detectors, some of which are intended for future small satellite missions as well as medical applications. However, the image obtained by a Compton camera has strong artifacts owing to the overlap of the Compton cones or the arcs, which degrade the resolution and sensitivity of the image. In this study, we revisit the adaptive ARM cut that significantly reduces artifacts when the direction of gamma ray emitting source is already known. This approach complements the statistically well-defined method based on the response function in the three-dimensional data space of scattering direction (χ, ψ) and scattering angle θ, but it is more direct, intuitive, and simplifies the extraction of spectra in astronomical observations of point-like sources. Using a Compton camera, INSPIRE, onboard the ultra-small satellite GRAPHIUM as an example, we numerically evaluated the extent of background reduction to estimate simulation-based sensitivity. The method was also applied to actual measurements using a quarter-scale prototype of INSPIRE to extract spectra from multiple sources within the same field of view.

astro-ph.IM

Measurement of the charge-to-mass ratio of particles trapped by the Paul trap for education

Paul traps are devices that confine particles using an alternating electric field and have been used in undergraduate experimental classes at universities. Owing to the requirement of a high voltage ($> 10^3$ V), Paul traps are not used in middle and high schools. Therefore, we developed an all-in-one-type Paul trap , including a high-voltage transformer. The Paul trap can be equipped with two different types of electrode attachments, ring-type and linear-type, and the trap image can be observed using a built-in web camera. For example, the charge-to-mass ratio of particles was measured with different types of attachments, and reasonable values were obtained. These types of trap devices are currently used at several educational facilities in Japan.

physics.ed-ph

An accelerator experiment for junior and senior high school students to improve students' involvement in fundamental physics

In Japan, research activities by junior and senior high school students show an upward trend. However, there are limited examples of research activities in the field of elementary particles and atoms. This is due to the difficulty associated with procuring research tools such as accelerators or particle detectors. Therefore, we hosted the "Accel Kitchen" in 2018 and 2019 at Cyclotron and Radioisotope Center (CYRIC) in Tohoku University where junior and senior high school students could participate in ongoing research of particle and atomic physics. At each workshop, 12 junior and senior high school students participated in the beam experiment, including the production of francium atoms (Fr) by the fusion reaction of oxygen and gold, optimizing the transport of the ion beam and identifying the alpha decay nuclei, and laser trapping of Fr for two days. Each group that was involved in the experiment was supported by researchers and university students who acted as mentors. This was the first opportunity for junior and senior high school students to know about the particle beam experiment in Japan.

physics.ed-ph

Development of microwave cavities for measurement of muonium hyperfine structure at J-PARC

The MuSEUM collaboration is planning measurements of the ground-state hyperfine structure (HFS) of muonium at the Japan Proton Accelerator Research Complex (J-PARC), Materials and Life Science Experimental Facility. The high-intensity beam that will soon be available at H-line allows for more precise measurements by one order of magnitude. We plan to conduct two staged measurements. First, we will measure the Mu-HFS in a near-zero magnetic field, and thereafter we will measure it in a strong magnetic field. We have developed two microwave cavities for this purpose. Furthermore, we evaluated systematic uncertainties from such a fluctuation of microwave fields and confirm the requirement of the microwave system, we use a microwave field distribution calculated from the finite element method.

physics.ins-det

Improved search for neutron to mirror-neutron oscillations in the presence of mirror magnetic fields with a dedicated apparatus at the PSI UCN source

While the international nEDM collaboration at the Paul Scherrer Institut (PSI) took data in 2017 that covered a considerable fraction of the parameter space of claimed potential signals of hypothetical neutron ($n$) to mirror-neutron ($n'$) transitions, it could not test all claimed signal regions at various mirror magnetic fields. Therefore, a new study of $n-n'$ oscillations using stored ultracold neutrons (UCNs)is underway at PSI, considerably expanding the reach in parameter space of mirror magnetic fields ($B'$) and oscillation time constants ($τ_{nn'}$). The new apparatus is designed to test for the anomalous loss of stored ultracold neutrons as a function of an applied magnetic field. The experiment is distinguished from its predecessors by its very large storage vessel (1.47\,m$^3$), enhancing its statistical sensitivity. In a test experiment in 2020 we have demonstrated the capabilities of our apparatus. However, the full analysis of our recent data is still pending. Based on already demonstrated performance, we will reach a sensitivity to oscillation times $τ_{nn'}/\sqrt{\cos(β)}$ well above hundred seconds, with $β$ being the angle between $B'$ and the applied magnetic field $B$. The scan of $B$ will allow the finding or the comprehensive exclusion of potential signals reported in the analysis of previous experiments and suggested to be consistent with neutron to mirror-neutron oscillations.

physics.ins-det

Two-dimensional beam profile monitor for the detection of alpha-emitting radioactive isotope beam

Ions with similar charge-to-mass ratios cannot be separated from existing beam profile monitors (BPMs) in nuclear facilities in which low-energy radioactive ions are produced due to nuclear fusion reactions. In this study, we developed a BPM using a microchannel plate and a charge-coupled device to differentiate the beam profiles of alpha-decaying radioactive isotopes from other ions (reaction products) produced in a nuclear reaction. This BPM was employed to optimize the low-energy radioactive francium ion (Fr+) beam developed at the Cyclotron and Radioisotope Center (CYRIC), Tohoku University, for electron permanent electric dipole moment (e-EDM) search experiments using Fr atoms. We demonstrated the performance of the BPM by separating the Fr+ beam from other reaction products produced during the nuclear fusion reaction of an oxygen (18O) beam and gold (197Au) target. However, as the mass of Au is close to that of Fr, separating the ions of these elements using a mass filter is a challenge, and a dominant number of Au+ renders the Fr+ beam profile invisible when using a typical BPM. Therefore, by employing the new BPM, we could successfully observe the Fr+ beam and other ion beams distinctly by measuring the alpha decay of Fr isotopes. This novel technique to monitor the alpha-emitting radioactive beam covers a broad range of lifetimes, for example, from approximately 1 s to 10 min, and can be implemented for other alpha-emitter beams utilized for medical applications.

physics.ins-det

New precise spectroscopy of the hyperfine structure in muonium with a high-intensity pulsed muon beam

A hydrogen-like atom consisting of a positive muon and an electron is known as muonium. It is a near-ideal two-body system for a precision test of bound-state theory and fundamental symmetries. The MuSEUM collaboration performed a new precision measurement of the muonium ground-state hyperfine structure at J-PARC using a high-intensity pulsed muon beam and a high-rate capable positron counter. The resonance of hyperfine transition was successfully observed at a near-zero magnetic field, and the muonium hyperfine structure interval of $ν_{\text{HFS}}$ = 4.463302(4) GHz was obtained with a relative precision of 0.9 ppm. The result was consistent with the previous ones obtained at Los Alamos National Laboratory and the current theoretical calculation. We present a demonstration of the microwave spectroscopy of muonium for future experiments to achieve the highest precision.

hep-ex

Rabi-Oscillation Spectroscopy of the Hyperfine Structure of Muonium Atoms

As a new method to determine the resonance frequency, Rabi-oscillation spectroscopy has been developed. In contrast to the conventional spectroscopy which draws the resonance curve, Rabi-oscillation spectroscopy fits the time evolution of the Rabi oscillation. By selecting the optimized frequency, it is shown that the precision is twice as good as the conventional spectroscopy with a frequency sweep. Furthermore, the data under different conditions can be treated in a unified manner, allowing more efficient measurements for systems consisting of a limited number of short-lived particles produced by accelerators such as muons. We have developed a fitting function that takes into account the spatial distribution of muonium and the spatial distribution of the microwave intensity to apply the new method to ground-state muonium hyperfine structure measurements at zero field. This was applied to the actual measurement data and the resonance frequencies were determined under various conditions. The result of our analysis gives $ν_{\rm HFS}=4\ 463\ 301.61 \pm 0.71\ {\rm kHz}$, which is the world's highest precision under zero field conditions.

hep-ex