Measurement of the free ion yield and estimate of the electron mobility of Trimethyl-Bismuth (TMBi)

This paper investigates the physical characteristics of the liquid Trimethyl-Bismuth (TMBi) relevant for charge readout in potential TMBi filled detectors for Positron-Emission-Tomography (PET) instruments. The high photo-efficiency and the possibility of fast timing by detection of Cherenkov light created in the liquid are both favorable for use of TMBi in a PET system. However, to obtain a high position and energy resolution also a readout of the charge signal created due to the absorption of a 511 keV photon is required. For this purpose the liquid has to be clean of electro-negative and ionic impurities. A distillation technique was developed within this study as one of the possible methods to remove such impurities and a measurement on the efficiency of this cleaning method is provided. The relevant quantities for an efficient charge readout are the free ion yield and the electron mobility of the liquid. We report on a new measurement of the zero-field free ion yield in TMBi and, using that result, produce an estimate of the electron mobility. The rather low zero-field free ion yield and its much lower expected electron mobility compared to tetramethyl-n compounds like TMSi question the use of the trimethyl molecule TMBi for a PET detector liquid. But we are also giving arguments that the tetramethyl molecule TMPb could be an interesting alternative.

physics.ins-det↗

Electro-purification studies and first measurement of relative permittivity of TMBi

A new type of detector for positron-emission tomography (PET) has been proposed recently, using a heavy organo-metallic liquid - TriMethyl Bismuth (TMBi) - as target material. TMBi is a transparent liquid with the high Z element Bismuth contributing 82% of its mass. 511keV annihilation photons are converted efficiently into photo-electrons within the detector material producing both Cherenkov light and free charge carriers in the liquid. While the optical component enables a fast timing, a charge readout using a segmented anode can provide an accurate position reconstruction and energy determination. The charge measurement requires a high level of purification, as any electronegative contaminants cause signal degradation. In addition to the purity requirements, the reactive nature of TMBi poses many challenges that need to be met until a fully functioning detector for PET applications can be realized. The paper presents an experimental setup that aims to remove electronegative impurities by electrostatic filtering and to characterise the properties of TMBi, e.g. the relative permittivity, for its application as a detector medium for charge read out.

physics.ins-det↗

High resolution MCP-PMT Readout Using Transmission Lines

We study the potential of the MCP-PMT read-out to detect single photo-electron using transmission lines. Such a solution limits the number of read-out channels, has a uniform time resolution across the PMT surface and provides quasi-continuous measurement of the spatial coordinates. The proposed solution is designed to be used in the BOLD-PET project aiming to develop an innovative detection module for the positron emission tomography using the liquid detection media, the tri-methyl bismuth. In this study we use the commercial MCP-PMT Planacon from Photonis, with 32x32 anode structure. The PCB gathers signals from anode pads in 32 transmission lines which are read-out from both ends. Amplifier boards and SAMPIC modules, developed in our labs, allow us to realize the cost-effective, multi-channel digitization of signals with excellent precision. For a single photo-electron, we measured a time resolution of 70~ps (FWHM) simultaneously with a spatial accuracy of 1.6~mm and 0.9~mm (FWHM) along and across transmission lines correspondingly.

physics.ins-det↗