SearcharxivSearch

arXiv subjects

K. Schmitt

Publications and source records attributed to K. Schmitt.

4 recordsLinked to original sources

Properties of correlated fission fragments from neutron induced fission of Np-237 at incident neutron energies between 200 keV and 100 MeV

Neutron-induced fission of $^{237}$Np has been measured over a wide range of incident neutron energies using a twin Frisch-gridded ionization chamber (TFGIC) and a thin-backed $^{237}$Np target. These measurements were performed at the Los Alamos Neutron Science Center - Weapons Neutron Research (LANSCE - WNR) facility, which provides a collimated beam of neutrons with energies ranging from 100s of keV to 100s of MeV. The data were analyzed using the double-energy ($2E$) method, with mass-dependent corrections for prompt-fission neutrons and pulse height defect. Pre- and post-neutron evaporation average total kinetic energy ($\langle TKE\rangle$) values are reported for 54 incident neutron energies in the energy range $0.20 \le E_n \le 100.0$ MeV and compared to existing data and evaluations. Pre- and post-neutron evaporation mass yields were extracted with a full width at half maximum (FWHM) resolution of 4u and compared to existing data and evaluations. The present $\langle TKE\rangle$ and mass yield data agree with previous results and also with statistical models of $^{237}$Np$(n,f)$ at incident neutron energies between $E_n = 0.2 - 20.0$ MeV. A flattening of the $\langle TKE\rangle$ data is observed (relative to the prediction of the GEF model) above $E_n = 20.0$ MeV. However, the interpretation of this discrepancy is unclear as the analysis method's neglect of incomplete momentum transfer at high energies, as well as pre-equilibrium pre-fission phenomena likely have a significant impact on the measurement at such high incident neutron energies.

nucl-ex

Conceptual design and first results for a neutron detector with interaction localization capabilities

A new high-precision detector for studying neutrons from beta-delayed neutron emission and direct reaction studies is proposed. The Neutron dEtector with Xn Tracking (NEXT) array is designed to maintain high intrinsic neutron detection efficiency while reducing uncertainties in neutron energy measurements. A single NEXT module is composed of thin segments of plastic scintillator, each optically separated, capable of neutron-gamma discrimination. Each segmented module is coupled to position sensitive photodetectors enabling the high-precision determination of neutron time of arrival and interaction position within the active volume. A design study has been conducted based on simulations and experimental tests leading to the construction of prototype units. First results from measurements using a $^{252}$Cf neutron source and accelerator-produced monoenergetic neutrons are presented.

physics.ins-det

Neutron-proton asymmetry dependence of spectroscopic factors in Ar isotopes

Spectroscopic factors have been extracted for proton rich 34Ar and neutron rich 46Ar using the (p,d) neutron transfer reaction. The experimental results show little reduction of the ground state neutron spectroscopic factor of the proton rich nucleus 34Ar compared to that of 46Ar. The results suggest that correlations, which generally reduce such spectroscopic factors, do not depend strongly on the neutron-proton asymmetry of the nucleus in this isotopic region as was reported in knockout reactions. The present results are consistent with results from systematic studies of transfer reactions but inconsistent with the trends observed in knockout reaction measurements.

nucl-ex

The VLQ Calorimeter of H1 at HERA: A Highly Compact Device for Measurements of Electrons and Photons under Very Small Scattering Angles

In 1998, the detector H1 at HERA has been equipped with a small backward spectrometer, the Very Low Q^2 (VLQ) spectrometer comprising a silicon tracker, a tungsten - scintillator sandwich calorimeter, and a Time-of-Flight system. The spectrometer was designed to measure electrons scattered under very low angles, equivalent to very low squared four - momentum transfers Q^2, and high energy photons with good energy and spatial resolution. The VLQ was in operation during the 1999 and 2000 run periods. This paper describes the design and construction of the VLQ calorimeter, a compact device with a fourfold projective energy read-out, and its performance during test runs and in the experiment.

physics.ins-det