SearcharxivSearch

arXiv subjects

K. Skarpaas

Publications and source records attributed to K. Skarpaas.

At least 19 recordsLinked to original sources

Design of a high voltage delivery system for noble liquid time projection chambers

Noble liquid time projection chambers (TPCs) are a leading technology in the detection of ionizing radiation, particularly in applications such as accelerator neutrino physics, dark matter detection, and neutrinoless double beta decay. This paper addresses the design considerations for implementing stable high voltage (HV) systems within large noble liquid TPCs, with a focus on the nEXO experiment. Utilizing insights from prior HV research and experimental investigations, we outline factors influencing HV stability and discuss design choices to improve stability and prevent electrical discharges. A novel HV delivery system concept is presented, tailored for the nEXO TPC, which incorporates these design considerations while also meeting the stringent radiopurity requirements of the nEXO neutrinoless double beta decay search. These design considerations and their specific implementation towards a HV delivery system offer guidance to future experiments applying high voltage in noble liquid environments.

physics.ins-det

Novel High-Radiopurity Doped Amorphous Silicon Resistors for Low-Background Detectors

We present the results of a study of lightly doped amorphous silicon used as a resistive medium for high-radiopurity resistors in nuclear and particle physics research instrumentation. Prototypes are produced for a Time Projection Chamber design for the nEXO neutrinoless double-beta decay search experiment that meet requirements for ultra-high radiopurity, good mechanical, cryogenic and high voltage performance, as well as useful vacuum ultraviolet (VUV) reflectivity. Further study is warranted to refine production methods and to confirm that the technology used here is useful for more general applications.

physics.ins-det

Search for Double Beta Decays of $^{134}$Xe with EXO-200 Phase II

EXO-200 was a leading double beta decay experiment consisting of a single-phase, enriched liquid xenon time projection chamber filled with an admixture of 80.672% $^{136}$Xe and 19.098% $^{134}$Xe. The detector operated at WIPP between 2010 and 2018 and was designed to search for double beta decay of $^{136}$Xe. Data was acquired in two phases separated by a period of detector upgrades. We report on the search for $0\nu\beta\beta$ and $2\nu\beta\beta$ decay of $^{134}$Xe with Phase II EXO-200 data, with median 90% C.L. exclusion sensitivity $T_{1/2}^{0\nu} \geq 3.7\times 10^{23}$ yr and $T_{1/2}^{2\nu} \geq 2.6 \times 10^{21}$ yr, respectively. No statistically significant signal is observed for either decay mode. We set a world-leading lower limit on the half-life of the neutrinoless decay mode of $^{134}$Xe of $T_{1/2}^{0\nu} \geq 8.7\times10^{23}$ (90% C.L.) and the second strongest constraint on the two-neutrino decay of $T_{1/2}^{2\nu} \geq 2.9\times10^{21}$ (90% C.L.), a 3-fold improvement over the EXO-200 Phase I measurement. New constraints are also set for the $2\nu\beta\beta$ and $0\nu\beta\beta$ decays of $^{134}$Xe to the lowest excited state of $^{134}$Ba.

nucl-ex

Search for Two-neutrino Double-Beta Decay of $^{136}\rm Xe$ to the $0^+_1$ excited state of $^{136}\rm Ba$ with the Complete EXO-200 Dataset

A new search for two-neutrino double-beta ($2νββ$) decay of $^{136}\rm Xe$ to the $0^+_1$ excited state of $^{136}\rm Ba$ is performed with the full EXO-200 dataset. A deep learning-based convolutional neural network is used to discriminate signal from background events. Signal detection efficiency is increased relative to previous searches by EXO-200 by more than a factor of two. With the addition of the Phase II dataset taken with an upgraded detector, the median 90$\%$ confidence level half-life sensitivity of $2νββ$ decay to the $0^+_1$ state of $^{136}\rm Ba$ is $2.9 \times 10^{24}~\rm yr$ using a total $^{136}\rm Xe$ exposure of $234.1~\rm kg~yr$. No statistically significant evidence for $2νββ$ decay to the $0^+_1$ state is observed, leading to a lower limit of $T^{2ν}_{1/2}(0^+ \rightarrow 0^+_1) > 1.4\times10^{24}~\rm yr$ at 90$\%$ confidence level, improved by 70$\%$ relative to the current world's best constraint.

hep-ex

Generative Adversarial Networks for Scintillation Signal Simulation in EXO-200

Generative Adversarial Networks trained on samples of simulated or actual events have been proposed as a way of generating large simulated datasets at a reduced computational cost. In this work, a novel approach to perform the simulation of photodetector signals from the time projection chamber of the EXO-200 experiment is demonstrated. The method is based on a Wasserstein Generative Adversarial Network - a deep learning technique allowing for implicit non-parametric estimation of the population distribution for a given set of objects. Our network is trained on real calibration data using raw scintillation waveforms as input. We find that it is able to produce high-quality simulated waveforms an order of magnitude faster than the traditional simulation approach and, importantly, generalize from the training sample and discern salient high-level features of the data. In particular, the network correctly deduces position dependency of scintillation light response in the detector and correctly recognizes dead photodetector channels. The network output is then integrated into the EXO-200 analysis framework to show that the standard EXO-200 reconstruction routine processes the simulated waveforms to produce energy distributions comparable to that of real waveforms. Finally, the remaining discrepancies and potential ways to improve the approach further are highlighted.

hep-ex

Search for MeV Electron Recoils from Dark Matter in EXO-200

We present a search for electron-recoil signatures from the charged-current absorption of fermionic dark matter using the EXO-200 detector. We report an average electron recoil background rate of $6.8 \times 10^{-4}\, \mathrm{cts}\,\mathrm{kg}^{-1}\mathrm{yr}^{-1}\mathrm{keV}^{-1}$ above $4\,\mathrm{MeV}$ and find no statistically significant excess over our background projection. Using a total ${}^{136}\mathrm{Xe}$ exposure of $234.1\,\mathrm{kg}\,\mathrm{yr}$ we exclude new parameter space for the charged-current absorption cross-section for dark matter masses between $m_χ= 2.6\,\mathrm{MeV} - 11.6\,\mathrm{MeV}$ with a minimum of $6\times 10^{-51}\,\mathrm{cm}^2$ at $8.3\,\mathrm{MeV}$ at the $90\%$ confidence level.

hep-ex

Search for Majoron-emitting modes of $^{136}$Xe double beta decay with the complete EXO-200 dataset

A search for Majoron-emitting modes of the neutrinoless double-beta decay of $^{136}$Xe is performed with the full EXO-200 dataset. This dataset consists of a total $^{136}$Xe exposure of 234.1 kg$\cdot$yr, and includes data with detector upgrades that have improved the energy threshold relative to previous searches. A lower limit of T$_{1/2}^{\rm{^{136}Xe}}>$4.3$\cdot$10$^{24}$ yr at 90\% C.L. on the half-life of the spectral index $n=1$ Majoron decay was obtained, a factor of 3.6 more stringent than the previous limit from EXO-200, corresponding to a constraint on the Majoron-neutrino coupling constant of $|\langle g_{ee}^{M}\rangle|$$<(0.4$-$0.9)\cdot10^{-5}$. The lower threshold and the additional data taken resulted in a factor 8.4 improvement for the $n=7$ mode compared to the previous EXO search. This search provides the most stringent limits to-date on the Majoron-emitting decays of $^{136}$Xe with spectral indices $n=1,2,3,$ and 7.

hep-ex

Design and production of the high voltage electrode grids and electron extraction region for the LZ dual-phase xenon time projection chamber

The dual-phase xenon time projection chamber (TPC) is a powerful tool for direct-detection experiments searching for WIMP dark matter, other dark matter models, and neutrinoless double-beta decay. Successful operation of such a TPC is critically dependent on the ability to hold high electric fields in the bulk liquid, across the liquid surface, and in the gas. Careful design and construction of the electrodes used to establish these fields is therefore required. We present the design and production of the LUX-ZEPLIN (LZ) experiment's high-voltage electrodes, a set of four woven mesh wire grids. Grid design drivers are discussed, with emphasis placed on design of the electron extraction region. We follow this with a description of the grid production process and a discussion of steps taken to validate the LZ grids prior to integration into the TPC.

physics.ins-det

Measurement of the Spectral Shape of the beta-decay of 137Xe to the Ground State of 137Cs in EXO-200 and Comparison with Theory

We report on a comparison between the theoretically predicted and experimentally measured spectra of the first-forbidden non-unique $β$-decay transition $^{137}\textrm{Xe}(7/2^-)\to\,^{137}\textrm{Cs}(7/2^+)$. The experimental data were acquired by the EXO-200 experiment during a deployment of an AmBe neutron source. The ultra-low background environment of EXO-200, together with dedicated source deployment and analysis procedures, allowed for collection of a pure sample of the decays, with an estimated signal-to-background ratio of more than 99-to-1 in the energy range from 1075 to 4175 keV. In addition to providing a rare and accurate measurement of the first-forbidden non-unique $β$-decay shape, this work constitutes a novel test of the calculated electron spectral shapes in the context of the reactor antineutrino anomaly and spectral bump.

nucl-ex

An improved measurement of the 2νββ half-life of Xe-136 with EXO-200

We report on an improved measurement of the 2νββ half-life of Xe-136 performed by EXO-200. The use of a large and homogeneous time projection chamber allows for the precise estimate of the fiducial mass used for the measurement, resulting in a small systematic uncertainty. We also discuss in detail the data analysis methods used for double-beta decay searches with EXO-200, while emphasizing those directly related to the present measurement. The Xe-136 2νββ half-life is found to be 2.165 +- 0.016 (stat) +- 0.059 (sys) x 10^21 years. This is the most precisely measured half-life of any 2νββ decay to date.

nucl-ex

The EXO-200 detector, part I: Detector design and construction

EXO-200 is an experiment designed to search for double beta decay of $^{136}$Xe with a single-phase, liquid xenon detector. It uses an active mass of 110 kg of xenon enriched to 80.6% in the isotope 136 in an ultra-low background time projection chamber capable of simultaneous detection of ionization and scintillation. This paper describes the EXO-200 detector with particular attention to the most innovative aspects of the design that revolve around the reduction of backgrounds, the efficient use of the expensive isotopically enriched xenon, and the optimization of the energy resolution in a relatively large volume.

physics.ins-det

Observation of Two-Neutrino Double-Beta Decay in Xe-136 with EXO-200

We report the observation of two-neutrino double-beta decay in Xe-136 with T_1/2 = 2.11 +- 0.04 (stat.) +- 0.21 (sys.) x 10^21 yr. This second order process, predicted by the Standard Model, has been observed for several nuclei but not for Xe-136. The observed decay rate provides new input to matrix element calculations and to the search for the more interesting neutrino-less double-beta decay, the most sensitive probe for the existence of Majorana particles and the measurement of the neutrino mass scale.

nucl-ex

Xenon purity analysis for EXO-200 via mass spectrometry

We describe purity measurements of the natural and enriched xenon stockpiles used by the EXO-200 double beta decay experiment based on a mass spectrometry technique. The sensitivity of the spectrometer is enhanced by several orders of magnitude by the presence of a liquid nitrogen cold trap, and many impurity species of interest can be detected at the level of one part-per-billion or better. We have used the technique to screen the EXO-200 xenon before, during, and after its use in our detector, and these measurements have proven useful. This is the first application of the cold trap mass spectrometry technique to an operating physics experiment.

physics.ins-det

A magnetically-driven piston pump for ultra-clean applications

A magnetically driven piston pump for xenon gas recirculation is presented. The pump is designed to satisfy extreme purity and containment requirements, as is appropriate for the recirculation of isotopically enriched xenon through the purification system and large liquid xenon TPC of EXO-200. The pump, using sprung polymer gaskets, is capable of pumping more than 16 standard liters per minute (SLPM) of xenon gas with 750 torr differential pressure.

physics.ins-det

Characterization of large area APDs for the EXO-200 detector

EXO-200 uses 468 large area avalanche photodiodes (LAAPDs) for detection of scintillation light in an ultra-low-background liquid xenon (LXe) detector. We describe initial measurements of dark noise, gain and response to xenon scintillation light of LAAPDs at temperatures from room temperature to 169K - the temperature of liquid xenon. We also describe the individual characterization of more than 800 LAAPDs for selective installation in the EXO-200 detector.

physics.ins-det

Systematic study of trace radioactive impurities in candidate construction materials for EXO-200

The Enriched Xenon Observatory (EXO) will search for double beta decays of 136Xe. We report the results of a systematic study of trace concentrations of radioactive impurities in a wide range of raw materials and finished parts considered for use in the construction of EXO-200, the first stage of the EXO experimental program. Analysis techniques employed, and described here, include direct gamma counting, alpha counting, neutron activation analysis, and high-sensitivity mass spectrometry.

physics.ins-det

Observation of single collisionally cooled trapped ions in a buffer gas

Individual Ba ions are trapped in a gas-filled linear ion trap and observed with a high signal-to-noise ratio by resonance fluorescence. Single-ion storage times of ~5 min (~1 min) are achieved using He (Ar) as a buffer gas at pressures in the range 8e-5 - 4e-3 torr. Trap dynamics in buffer gases are experimentally studied in the simple case of single ions. In particular, the cooling effects of light gases such as He and Ar and the destabilizing properties of heavier gases such as Xe are studied. A simple model is offered to explain the observed phenomenology.

physics.atom-ph

A liquid xenon ionization chamber in an all-fluoropolymer vessel

A novel technique has been developed to build vessels for liquid xenon ionization detectors entirely out of ultra-clean fluoropolymer. We describe the advantages in terms of low radioactivity contamination, provide some details of the construction techniques, and show the energy resolution achieved with a prototype all-fluoropolymer ionization detector.

physics.ins-det