SearcharxivSearch

arXiv subjects

K. Stahl

Publications and source records attributed to K. Stahl.

3 recordsLinked to original sources

High-accuracy multi-ion spectroscopy with mixed-species Coulomb crystals

Multi-ion optical clocks offer the possibility of overcoming the low signal-to-noise ratio of single-ion clocks, while still providing low systematic uncertainties. We present simultaneous spectroscopy of up to four ${}^{115}$In${}^+$ clock ions in a linear Coulomb crystal, sympathetically cooled with ${}^{172}$Yb${}^+$ ions. In first clock comparisons, we see agreement below $1\times10^{-17}$ with results obtained using a single In${}^+$ ion, for which we have evaluated the systematic uncertainty to be $2.5\times10^{-18}$. Operation with four clock ions reduces the instability from $1.6\times10^{-15}/\sqrt{t/(1\;\mathrm{s})}$ to $9.2\times10^{-16}/\sqrt{t/(1\;\mathrm{s})}$. We derive a model for decay-related dead time during state preparation, which matches the observed scaling of instability with clock ion number $N$, and indicates that $1/\sqrt{N}$ scaling can be achieved with the addition of a repump laser.

physics.atom-ph

$^{115}$In$^+$-$^{172}$Yb$^+$ Coulomb crystal clock with $2.5\times10^{-18}$ systematic uncertainty

We present a scalable mixed-species Coulomb crystal clock based on the $^1S_0$ $\leftrightarrow$ $^3P_0$ transition in $^{115}$In$^+$. $^{172}$Yb$^+$ ions are co-trapped and used for sympathetic cooling. Reproducible interrogation conditions for mixed-species Coulomb crystals are ensured by a conditional preparation sequence with permutation control. We demonstrate clock operation with a 1In$^+$-3Yb$^+$ crystal, achieving a relative systematic uncertainty of $2.5\times10^{-18}$ and a relative frequency instability of $1.6\times10^{-15}/\sqrt{τ/1\;\mathrm{s}}$. We report on absolute frequency measurements with an uncertainty of $1.3\times10^{-16}$ and optical frequency comparisons with clocks based on $^{171}$Yb$^+$ (E3) and $^{87}$Sr. With a fractional uncertainty of $4.4\times10^{-18}$, the former is - to our knowledge - the most accurate frequency ratio value reported to date. For the $^{115}$In$^+$/$^{87}$Sr ratio, we improve upon the best previous measurement by more than an order of magnitude. We also demonstrate operation with four $^{115}$In$^+$ clock ions, which reduces the instability to $9.2\times10^{-16}/\sqrt{τ/1\;\mathrm{s}}$.

physics.atom-ph

Gravity Probe B: Final Results of a Space Experiment to Test General Relativity

Gravity Probe B, launched 20 April 2004, is a space experiment testing two fundamental predictions of Einstein's theory of General Relativity (GR), the geodetic and frame-dragging effects, by means of cryogenic gyroscopes in Earth orbit. Data collection started 28 August 2004 and ended 14 August 2005. Analysis of the data from all four gyroscopes results in a geodetic drift rate of -6,601.8+/- 18.3 mas/yr and a frame-dragging drift rate of -37.2 +/- 7.2 mas/yr, to be compared with the GR predictions of -6,606.1 mas/yr and -39.2 mas/yr, respectively (`mas' is milliarc-second; 1mas = 4.848 x 10-9 rad).

gr-qc