SearcharxivSearch

arXiv subjects

K. Tkalcec

Publications and source records attributed to K. Tkalcec.

2 recordsLinked to original sources

A prototype differential atom interferometer for fundamental physics

Gravitational waves and ultralight dark matter are among the most compelling frontiers in fundamental physics, motivating proposals for Very Long-Baseline Atom Interferometers (VLBAIs) such as AION, MAGIS, AICE and AEDGE that aim to detect frequencies at which ground-based and space-borne laser interferometers lose sensitivity. VLBAIs look for signals by comparing the quantum phase evolution of widely separated atomic ensembles interrogated by a common laser. However, their performance depends critically on suppressing noise sources, particularly laser phase noise. Experimental validation of such noise rejection remains an important challenge. Here we demonstrate a prototype differential atom interferometer based on the single-photon clock transition of fermionic 87Sr, realising for the first time a gradiometer configuration with a species intrinsically suited to kilometre-scale and space-baseline operation. The instrument operates at the Standard Quantum Limit with no excess noise beyond atom shot noise, and the differential configuration maintains quantum-limited sensitivity in the presence of several radians of artificially injected laser phase noise per shot, emulating the conditions expected in a VLBAI. We further demonstrate recovery of coherent oscillatory signals across a broad frequency range under fully phase-randomised conditions, a capability that is inaccessible to a single interferometer operating in the same regime. These results provide an experimental validation of the noise-immune measurement principle underlying VLBAIs and mark an important step towards next-generation quantum sensors for gravitational-wave detection and searches for ultralight dark matter.

hep-ex

Centralised Design and Production of the Ultra-High Vacuum and Laser-Stabilisation Systems for the AION Ultra-Cold Strontium Laboratories

This paper outlines the centralised design and production of the Ultra-High-Vacuum sidearm and Laser-Stabilisation systems for the AION Ultra-Cold Strontium Laboratories. Commissioning data on the residual gas and steady-state pressures in the sidearm chambers, on magnetic field quality, on laser stabilisation, and on the loading rate for the 3D Magneto-Optical Trap are presented. Streamlining the design and production of the sidearm and laser stabilisation systems enabled the AION Collaboration to build and equip in parallel five state-of-the-art Ultra-Cold Strontium Laboratories within 24 months by leveraging key expertise in the collaboration. This approach could serve as a model for the development and construction of other cold atom experiments, such as atomic clock experiments and neutral atom quantum computing systems, by establishing dedicated design and production units at national laboratories.

physics.atom-ph