Searcharxiv⌕ Search

arXiv subjects

K. W. Lehnert

Publications and source records attributed to K. W. Lehnert.

At least 19 recordsLinked to original sources

Design of ALPHA Phase I: A Plasma Haloscope for 10--20 GHz Post-Inflation Axions

The axion is a well-motivated hypothetical particle capable of resolving both the strong CP problem and the dark matter mystery, with recent post-inflationary cosmological simulations favoring masses above 40 μeV. Plasma haloscopes serve as a promising experimental approach to reach theoretically preferred sensitivities in this mass range. ALPHA, hosted at Yale Wright Laboratory, is an international collaboration developing plasma haloscopes to search for QCD dark matter axions. In this letter we present the detailed design and sensitivity projection for the first phase of the ALPHA experiment, which will search the mass range from 10 GHz to 20 GHz (~40 μeV to 80 μeV). This search will make use of wire-array plasma resonators to decouple the physical size from the resonant frequency, a limitation typically faced by traditional microwave cavities, allowing broadband sensitivity approaching KSVZ coupling strengths.

hep-ex↗

High-throughput bidirectional electro-optic transduction assessed with a practical quantum capacity

A microwave-optical transducer of sufficiently low noise and high signal transfer rate would allow entanglement to be distributed between superconducting quantum processors reliably within the lifetimes of their quantum memories. To clarify the multifaceted performance required for such a task, we derive a broadband quantum channel capacity that bounds the maximum rate at which quantum information can be sent through realistic finite-bandwidth thermal-loss channels. This capacity serves as a comprehensive measure of transducer performance and provides insight into the relative importance of disparate metrics. We find that the broadband capacity depends on the throughput -- defined as the product of efficiency, bandwidth, and duty cycle -- and on the added noise. We present measurements of a membrane-based opto-electromechanical transducer with high throughput of 7 kHz and at an input-referred added noise of 3 photons in both upconversion and downconversion, demonstrating that bidirectional transducer capacities comparable to superconducting qubit decay rates are within reach. In downconversion, throughput of this magnitude at the few-photon noise level is unprecedented, marking an improvement of nearly four orders of magnitude over previous work.

quant-ph↗

A persistent-current-biased and current-actuated switch for superconducting circuits

Broadband and low-loss superconducting switches can facilitate large-scale quantum information processors and cryogenic detectors by dynamically reconfiguring the connectivity of their circuits. The time dependent connectivity is enabled by the nonlinearity of lossless Josephson junctions, which are often wired into superconducting loops to be controlled by magnetic flux. However, this approach needs a power-consuming constant flux bias and dynamic flux actuation, both of which are hard to isolate from other switches or flux sensitive elements, limiting their integration density. Here, we design and characterize a microwave switch that implements a persistent current bias and direct current actuation to reduce static power consumption, actuation energy and potential crosstalk to other devices. We show that persistent current associated with tens of flux quanta is stable and long-lived, reducing the need for on-the-fly tuning. We further demonstrate that our switch has desirable performance for superconducting-circuit-based quantum information processing, including an off mode with more than 20 dB isolation comparable to commercial ferrite isolators, power handling larger than 100 pW sufficient for resonator readout tones and amplifier pumps, and modulation bandwidth broader than 600 MHz useful for multiplexing schemes.

quant-ph↗

Search for Dark Photons between 16.96--19.52 $μ$eV with the HAYSTAC Experiment

We report dark photon results from HAYSTAC Phase II using data from previously reported axion searches. Additionally, we present an analysis of an unpublished dataset covering a region between 19.46--19.52 $μ$eV. This region overlaps with a recently reported dark photon signal at 19.5 $μ$eV with a kinetic coupling strength of $|χ_{\text{rand}}| \simeq 6.5 \times 10^{-15}$ resulting from a reanalysis of previously published data from the TASEH collaboration. Given HAYSTAC's sensitivity, if such a signal were present, it would have appeared as a large $17.1σ$ excess above the noise. However, no such signal was observed. We thus exclude couplings $|χ_{\text{rand}}|\geq 4.90\times10^{-15}$ at the 90\% confidence level over the newly reported region. In addition, using our previously reported axion data, we exclude couplings $|χ_{\text{rand}}|\geq2.90\times 10^{-15}$ between 16.96--19.46 $μ$eV at the 90\% confidence level.

hep-ex↗

Dark Matter Axion Search with HAYSTAC Phase II

This Letter reports new results from the HAYSTAC experiment's search for dark matter axions in our galactic halo. It represents the widest search to date that utilizes squeezing to realize sub-quantum limited noise. The new results cover 1.71 $μ$eV of newly scanned parameter space in the mass ranges 17.28-18.44 $μ$eV and 18.71-19.46 $μ$eV. No statistically significant evidence of an axion signal was observed, excluding couplings $|g_γ|\geq$ 2.75$\times$$|g_γ^{\text{KSVZ}}|$ and $|g_γ|\geq$ 2.96$\times$$|g_γ^{\text{KSVZ}}|$ at the 90$\%$ confidence level over the respective region. By combining this data with previously published results using HAYSTAC's squeezed state receiver, a total of 2.27 $μ$eV of parameter space has now been scanned between 16.96-19.46 $μ$eV, excluding $|g_γ|\geq$ 2.86$\times$$|g_γ^{\text{KSVZ}}|$ at the 90$\%$ confidence level. These results demonstrate the squeezed state receiver's ability to probe axion models over a significant mass range while achieving a scan rate enhancement relative to a quantum-limited experiment.

hep-ex↗

Protecting backaction-evading measurements from parametric instability

Noiseless measurement of a single quadrature in systems of parametrically coupled oscillators is theoretically possible by pumping at the sum and difference frequencies of the two oscillators, realizing a backaction-evading (BAE) scheme. Although this would hold true in the simplest scenario for a system with pure three-wave mixing, implementations of this scheme are hindered by unwanted higher-order parametric processes that destabilize the system and add noise. We show analytically that detuning the two pumps from the sum and difference frequencies can stabilize the system and fully recover the BAE performance, enabling operation at otherwise inaccessible cooperativities. We also show that the acceleration demonstrated in a weak signal detection experiment [PRX QUANTUM 4, 020302 (2023)] was only achievable because of this detuning technique.

quant-ph↗

Integrating planar circuits with superconducting 3D microwave cavities using tunable low-loss couplers

We design and test a low-loss interface between superconducting 3-dimensional microwave cavities and 2-dimensional circuits, where the coupling rate is highly tunable. This interface seamlessly integrates a loop antenna and a Josephson junction-based coupling element. We demonstrate that the loss added by connecting this interface to the cavity is 1.28 kHz, corresponding to an inverse quality factor of $1/(4.5 \times 10^6)$. Furthermore, we show that the cavity's external coupling rate to a 50 $Ω$ transmission line can be tuned from negligibly small to over 3 orders of magnitude larger than its internal loss rate in a characteristic time of 3.2 ns. This switching speed does not impose additional limits on the coupling rate because it is much faster than the coupling rate. Moreover, the coupler can be controlled by low frequency signals to avoid interference with microwave signals near the cavity or qubit frequencies. Finally, the coupling element introduces a 0.04 Hz/photon self-Kerr nonlinearity to the cavity, remaining linear in high photon number operations.

quant-ph↗

Axion Dark Matter

Axions are well-motivated dark matter candidates with simple cosmological production mechanisms. They were originally introduced to solve the strong CP problem, but also arise in a wide range of extensions to the Standard Model. This Snowmass white paper summarizes axion phenomenology and outlines next-generation laboratory experiments proposed to detect axion dark matter. There are vibrant synergies with astrophysical searches and advances in instrumentation including quantum-enabled readout, high-Q resonators and cavities and large high-field magnets. This white paper outlines a clear roadmap to discovery, and shows that the US is well-positioned to be at the forefront of the search for axion dark matter in the coming decade.

hep-ex↗

New Results from HAYSTAC's Phase II Operation with a Squeezed State Receiver

A search for dark matter axions with masses $>10 μeV/c^{2}$ has been performed using the HAYSTAC experiment's squeezed state receiver to achieve sub-quantum limited noise. This report includes details of the design and operation of the experiment previously used to search for axions in the mass ranges $16.96-17.12$ and $17.14-17.28 μeV/c^{2}$($4.100-4.140$GHz) and $4.145-4.178$GHz) as well as upgrades to facilitate an extended search at higher masses. These upgrades include improvements to the data acquisition routine which have reduced the effective dead time by a factor of 5, allowing for the new region to be scanned $\sim$1.6 times faster with comparable sensitivity. No statistically significant evidence of an axion signal is found in the range $18.44-18.71μeV/c^{2}$($4.459-4.523$GHz), leading to an aggregate upper limit exclusion at the $90\%$ level on the axion-photon coupling of $2.06\times g_γ^{KSVZ}$.

hep-ex↗

A cavity entanglement and state swapping method to accelerate the search for axion dark matter

In cavity-based axion dark matter detectors, quantum noise remains a primary barrier to achieving the scan rate necessary for a comprehensive search of axion parameter space. Here we introduce a method of scan rate enhancement in which an axion-sensitive cavity is coupled to an auxiliary resonant circuit through simultaneous two-mode squeezing (entangling) and state swapping interactions. We show analytically that when combined, these interactions can amplify an axion signal before it becomes polluted by vacuum noise introduced by measurement. This internal amplification yields a wider bandwidth of axion sensitivity, increasing the rate at which the detector can search through frequency space. With interaction rates predicted by circuit simulations of this system, we show that this technique can increase the scan rate up to 15-fold relative to the scan rate of a detector limited by vacuum noise.

quant-ph↗

Quantum enhanced metrology in the search for fundamental physical phenomena

These notes summarize lectures given at the 2019 Les Houches summer school on Quantum Information Machines. They describe and review an application of quantum metrology concepts to searches for ultralight dark matter. In particular, for ultralight dark matter that couples as a weak classical force to a laboratory harmonic oscillator, quantum squeezing benefits experiments in which the mass of the dark matter particle is unknown. This benefit is present even if the oscillatory dark matter signal is much more coherent than the harmonic oscillator that it couples to, as is the case for microwave frequency searches for dark matter axion particles.

quant-ph↗

Efficient and Low-Backaction Quantum Measurement Using a Chip-Scale Detector

Superconducting qubits are a leading platform for scalable quantum computing and quantum error correction. One feature of this platform is the ability to perform projective measurements orders of magnitude more quickly than qubit decoherence times. Such measurements are enabled by the use of quantum-limited parametric amplifiers in conjunction with ferrite circulators - magnetic devices which provide isolation from noise and decoherence due to amplifier backaction. Because these non-reciprocal elements have limited performance and are not easily integrated on-chip, it has been a longstanding goal to replace them with a scalable alternative. Here, we demonstrate a solution to this problem by using a superconducting switch to control the coupling between a qubit and amplifier. Doing so, we measure a transmon qubit using a single, chip-scale device to provide both parametric amplification and isolation from the bulk of amplifier backaction. This measurement is also fast, high fidelity, and has 70% efficiency, comparable to the best that has been reported in any superconducting qubit measurement. As such, this work constitutes a high-quality platform for the scalable measurement of superconducting qubits.

quant-ph↗

Squeezed vacuum used to accelerate the search for a weak classical signal

Many experiments that interrogate fundamental theories require detectors whose sensitivities are limited by the laws of quantum mechanics. In cavity-based searches for axionic dark matter, vacuum fluctuations in the two quadratures of the cavity electromagnetic field limit the sensitivity to an axion-induced field. In an apparatus designed to partially mimic existing axion detectors, we demonstrate experimentally that such quantum limits can be overcome through the use of squeezed states. By preparing a microwave cavity in a squeezed state and measuring just the squeezed quadrature, we enhance the spectral scan rate by a factor of $2.12 \pm 0.08$. This enhancement is in excellent quantitative agreement with a theoretical model accounting for both imperfect squeezing and measurement.

quant-ph↗

A quantum-enhanced search for dark matter axions

In dark matter axion searches, quantum uncertainty manifests as a fundamental noise source, limiting the measurement of the quadrature observables used for detection. We use vacuum squeezing to circumvent the quantum limit in a search for a new particle. By preparing a microwave-frequency electromagnetic field in a squeezed state and near-noiselessly reading out only the squeezed quadrature, we double the search rate for axions over a mass range favored by recent theoretical projections. We observe no signature of dark matter axions in the combined $16.96-17.12$ and $17.14-17.28\spaceμ\text{eV}/c^2$ mass window for axion-photon couplings above $g_γ = 1.38\times g_γ^\text{KSVZ}$, reporting exclusion at the 90% level.

quant-ph↗

An improved analysis framework for axion dark matter searches

In experiments searching for axionic dark matter, the use of the standard threshold-based data analysis discards valuable information. We present a Bayesian analysis framework that builds on an existing processing protocol to extract more information from the data of coherent axion detectors such as operating haloscopes. The analysis avoids logical subtleties that accompany the standard analysis framework and enables greater experimental flexibility on future data runs. Performing this analysis on the existing data from the HAYSTAC experiment, we find improved constraints on the axion-photon coupling $g_γ$ while also identifying the most promising regions of parameter space within the $23.15$--$24.0$ $μ$eV mass range. A comparison with the standard threshold analysis suggests a $36\%$ improvement in scan rate from our analysis, demonstrating the utility of this framework for future axion haloscope analyses.

astro-ph.IM↗

Harnessing electro-optic correlations in an efficient mechanical converter

An optical network of superconducting quantum bits (qubits) is an appealing platform for quantum communication and distributed quantum computing, but developing a quantum-compatible link between the microwave and optical domains remains an outstanding challenge. Operating at $T < 100$ mK temperatures, as required for quantum electrical circuits, we demonstrate a mechanically-mediated microwave-optical converter with 47$\%$ conversion efficiency, and use a feedforward protocol to reduce added noise to 38 photons. The feedforward protocol harnesses our discovery that noise emitted from the two converter output ports is strongly correlated because both outputs record thermal motion of the same mechanical mode. We also discuss a quantum feedforward protocol that, given high system efficiencies, allows quantum information to be transferred even when thermal phonons enter the mechanical element faster than the electro-optic conversion rate.

quant-ph↗

Design of an on-chip superconducting microwave circulator with octave bandwidth

We present a design for a superconducting, on-chip circulator composed of dynamically modulated transfer switches and delays. Design goals are set for the multiplexed readout of superconducting qubits. Simulations of the device show that it allows for low-loss circulation (insertion loss < 0.35 dB and isolation >20 dB) over an instantaneous bandwidth of 2.3 GHz. As the device is estimated to be linear for input powers up to -65 dBm, this design improves on the bandwidth and power-handling of previous superconducting circulators by over a factor of 50, making it ideal for integration with broadband quantum limited amplifiers.

quant-ph↗

Topological phase transition measured in a dissipative metamaterial

We construct a metamaterial from radio-frequency harmonic oscillators, and find two topologically distinct phases resulting from dissipation engineered into the system. These phases are distinguished by a quantized value of bulk energy transport. The impulse response of our circuit is measured and used to reconstruct the band structure and winding number of circuit eigenfunctions around a dark mode. Our results demonstrate that dissipation can lead to topological transport in a much wider class of physical systems than considered before.

cond-mat.mes-hall↗