SearcharxivSearch

arXiv subjects

K. Yanai

Publications and source records attributed to K. Yanai.

6 recordsLinked to original sources

A search for $\mu^+\to e^+\gamma$ with the first dataset of the MEG II experiment

The MEG II experiment, based at the Paul Scherrer Institut in Switzerland, reports the result of a search for the decay $\mu^+\to e^+\gamma$ from data taken in the first physics run in 2021. No excess of events over the expected background is observed, yielding an upper limit on the branching ratio of B($\mu^+\to e^+\gamma$) < $7.5 \times 10^{-13}$ (90% C.L.). The combination of this result and the limit obtained by MEG gives B($\mu^+\to e^+\gamma$) < $3.1 \times 10^{-13}$ (90% C.L.), which is the most stringent limit to date. A ten-fold larger sample of data is being collected during the years 2022-2023, and data-taking will continue in the coming years.

hep-ex

Operation and performance of MEG II detector

The MEG II experiment, located at the Paul Scherrer Institut (PSI) in Switzerland, is the successor to the MEG experiment, which completed data taking in 2013. MEG II started fully operational data taking in 2021, with the goal of improving the sensitivity of the mu+ -> e+ gamma decay down to 6e-14 almost an order of magnitude better than the current limit. In this paper, we describe the operation and performance of the experiment and give a new estimate of its sensitivity versus data acquisition time.

physics.ins-det

Search for lepton flavour violating muon decay mediated by a new light particle in the MEG experiment

We present the first direct search for lepton flavour violating muon decay mediated by a new light particle X, $μ^+ \to \mathrm{e}^+\mathrm{X}, \mathrm{X} \to γγ$. This search uses a dataset resulting from $7.5\times 10^{14}$ stopped muons collected by the MEG experiment at the Paul Scherrer Institut in the period 2009--2013. No significant excess is found in the mass region 20--45 MeV/c$^2$ for lifetimes below 40 ps, and we set the most stringent branching ratio upper limits in the mass region of 20--40 MeV/c$^2$, down to $\mathcal{O}(10^{-11})$ at 90\% confidence level.

hep-ex

Timing resolution of a plastic scintillator counter read out by radiation damaged SiPMs connected in series

This paper discusses the effects of radiation damage to SiPMs on the performances of plastic scintillator counters with series-connected SiPM readout, focusing on timing measurements. The performances of a counter composed of a $120 \times 40 \times5~\mathrm{mm}^3$ scintillator tile read out by two sets of six SiPMs from AdvanSiD connected in series attached on the short sides are presented, for different combinations of SiPMs at various levels of irradiation. Firstly, six SiPMs were equally irradiated with electrons from $^{90}$Sr sources up to a fluence of $Φ_\mathrm{e^-}\approx 3 \times 10^{12}~\mathrm{cm}^{-2}$. The timing resolution of the counter gradually deteriorated by the increase in dark current. The dark current and the deterioration were reduced when the counter was cooled from 30$^\circ$C to 10$^\circ$C. Secondly, 33 SiPMs were irradiated with reactor neutrons. The characteristics of counters read out by series-connected SiPMs with non-uniform damage levels, were investigated. The signal pulse height, the time response, and the timing resolution depend on the hit position in the counter, when SiPMs' irradiation is not uniform.

physics.ins-det

The laser-based time calibration system for the MEG II pixelated Timing Counter

We have developed a new laser-based time calibration system for highly segmented scintillator counters like the MEG II pixelated Timing Counter (pTC), consisting of 512-centimeter scale scintillator counters read out by silicon photomultipliers (SiPMs). It is difficult to apply previous laser-based calibration methods for conventional meter-scale Time-Of-Flight detectors to the MEG II pTC from the implementation and the accuracy points of view. This paper presents a new laser-based time calibration system which can overcome such difficulties. A laser pulse is split into each scintillator counter via several optical components so that we can directly measure the time offset of each counter relative to the laser-emitted time. We carefully tested all the components and procedures prior to the actual operation. The laser system was installed into the pTC and thoroughly tested under the real experimental condition. The system showed good stability and being sensitive to any change of timing larger than ~10 ps. Moreover, it showed an uncertainty of 48 ps in the determination of the time offsets, which meets our requirements. The new method provides an example of the implementation of a precise timing alignment for the new type of detectors enabled by the advance of SiPM technology.

physics.ins-det

Néel-type Skyrmion Lattice with Confined Orientation in the Polar Magnetic Semiconductor GaV$_4$S$_8$

Following the early prediction of the skyrmion lattice (SkL) - a periodic array of spin vortices - it has been observed recently in various magnetic crystals mostly with chiral structure. Although non-chiral but polar crystals with C$_{nv}$ symmetry were identifed as ideal SkL hosts in pioneering theoretical studies this archetype of SkL has remained experimentally unexplored. Here, we report the discovery of a SkL in the polar magnetic semiconductor GaV$_4$S$_8$ with rhombohedral (C$_{3v}$) symmetry and easy axis anisotropy. The SkL exists over an unusually broad temperature range compared with other bulk crystals and the orientation of the vortices is not controlled by the external magnetic feld but instead confned to the magnetic easy axis. Supporting theory attributes these unique features to a new non-chiral or Néel-type of SkL describable as a superposition of spin cycloids in contrast to the Bloch-type SkL in chiral magnets described in terms of spin helices.

cond-mat.mtrl-sci