SearcharxivSearch

arXiv subjects

Kairui Huang

Publications and source records attributed to Kairui Huang.

2 recordsLinked to original sources

Development of a sub-100 ps Time-of-Flight detector with SiPM-readout scintillator for measurement of cosmic muon velocity

Accurate Time-of-Flight (TOF) measurement with sub-100 picosecond resolution is a critical requirement for particle identification in future high-energy physics experiments, such as the Belle II $K_{L}$ and Muon (KLM) detector upgrade. Achieving this precision with large-area Silicon Photomultipliers (SiPMs) is challenging due to the inherent junction capacitance, which degrades signal rise time. In this work, we developed and evaluated a high-time-resolution cosmic ray detector based on plastic scintillators and customized SiPM arrays. To optimize the readout for block-shaped scintillators, we systematically compared different sensor topologies. We demonstrate that a multi-face readout topology, utilizing low-capacitance 4-series (4S) SiPM modules coupled to four faces of the scintillator, achieves an excellent coincidence time resolution of approximately 68 ps, outperforming the $\sim$100 ps resolution of the concentrated 4-series 3-parallel (4S3P) hybrid topology. Furthermore, to validate the system's practical performance, we successfully measured well-known cosmic ray observables, specifically the relativistic muon velocity via TOF reconstruction. These results highlight the potential of the multi-face 4S configuration as a high-precision solution for future TOF detector upgrades.

physics.ins-det

R&D of KLM Upgrade for Direct Measurement of Neutral Hadron Momentum via Time-of-Flight in Belle II

Accurate momentum determination of a neutral hadron, such as a KL meson or a neutron, remains a significant challenge in particle physics and nuclear physics experiments. The Belle II experiment presents an opportunity to address this challenge through an upgrade incorporating Time-of-Flight (TOF) capability for its large KL and Muon Detector (KLM). We investigate the feasibility of momentum determination via TOF measurement. To achieve high time resolution for the KLM upgrade, we conduct research and development of cost-effective plastic scintillators in collaboration with GaoNengKeDi Company, and technology utilizing silicon photomultipliers(SiPMs) arrays. A bulk attenuation length of 120 \pm 7 cm has been achieved with a 135 cm-long sample, along with a time resolution of 70 \pm 7 ps at its midpoint. A 50 cm-long scintillator demonstrates an exceptional time resolution of 47 \pm 2 ps. These results highlight the potential of the proposed technology for improving neutral hadron momentum measurements in an upgraded Belle II KLM detector.

physics.ins-det