SearcharxivSearch

arXiv subjects

Kaveh Ashenayi

Publications and source records attributed to Kaveh Ashenayi.

2 recordsLinked to original sources

Real-Time Surrogate Modeling for Fast Transient Prediction in Inverter-Based Microgrids Using CNN and LightGBM

Real-time monitoring of inverter-based microgrids is essential for stability, fault response, and operational decision-making. However, electromagnetic transient (EMT) simulations, required to capture fast inverter dynamics, are computationally intensive and unsuitable for real-time applications. This paper presents a data-driven surrogate modeling framework for fast prediction of microgrid behavior using convolutional neural networks (CNN) and Light Gradient Boosting Machine (LightGBM). The models are trained on a high-fidelity EMT digital twin dataset of a microgrid with ten distributed generators under eleven operating and disturbance scenarios, including faults, noise, and communication delays. A sliding-window method is applied to predict important system variables, including voltage magnitude, frequency, total active power, and voltage dip. The results show that model performance changes depending on the type of variable being predicted. The CNN demonstrates high accuracy for time-dependent signals such as voltage, with an $R^2$ value of 0.84, whereas LightGBM shows better performance for structured and disturbance-related variables, achieving an $R^2$ of 0.999 for frequency and 0.75 for voltage dip. A combined CNN+LightGBM model delivers stable performance across all variables. Beyond accuracy, the surrogate models also provide major improvements in computational efficiency. LightGBM achieves more than $1000\times$ speedup and runs faster than real time, while the hybrid model achieves over $500\times$ speedup with near real-time performance. These findings show that data-driven surrogate models can effectively represent microgrid dynamics. They also support real-time and faster-than-real-time predictions. As a result, they are well-suited for applications such as monitoring, fault analysis, and control in inverter-based power systems.

eess.SY

High-Fidelity Digital Twin Dataset Generation for Inverter-Based Microgrids Under Multi-Scenario Disturbances

Public power-system datasets often lack electromagnetic transient (EMT) waveforms, inverter control dynamics, and diverse disturbance coverage, which limits their usefulness for training surrogate models and studying cyber-physical behavior in inverter-based microgrids. This paper presents a high-fidelity digital twin dataset generated from a MATLAB/Simulink EMT model of a low-voltage AC microgrid with ten inverter-based distributed generators. The dataset records synchronized three-phase PCC voltages and currents, per-DG active power, reactive power, and frequency, together with embedded scenario labels, producing 38 aligned channels sampled at $Δt = 2~μ$s over $T = 1$~s ($N = 500{,}001$ samples) per scenario. Eleven operating and disturbance scenarios are included: normal operation, load step, voltage sag (temporary three-phase fault), load ramp, frequency ramp, DG trip, tie-line trip, reactive power step, single-line-to-ground faults, measurement noise injection, and communication delay. To ensure numerical stability without altering sequence length, invalid samples (NaN, Inf, and extreme outliers) are repaired using linear interpolation. Each scenario is further validated using system-level evidence from mean frequency, PCC voltage magnitude, total active power, voltage unbalance, and zero-sequence current to confirm physical observability and correct timing. The resulting dataset provides a consistent, labeled EMT benchmark for surrogate modeling, disturbance classification, robustness testing under noise and delay, and cyber-physical resilience analysis in inverter-dominated microgrids. The dataset and processing scripts will be released upon acceptance

eess.SY