Searcharxiv⌕ Search

arXiv subjects

Ke Sheng

Publications and source records attributed to Ke Sheng.

24 records · Page 2Linked to original sources

To what extent can Plug-and-Play methods outperform neural networks alone in low-dose CT reconstruction

The Plug-and-Play (PnP) framework was recently introduced for low-dose CT reconstruction to leverage the interpretability and the flexibility of model-based methods to incorporate various plugins, such as trained deep learning (DL) neural networks. However, the benefits of PnP vs. state-of-the-art DL methods have not been clearly demonstrated. In this work, we proposed an improved PnP framework to address the previous limitations and develop clinical-relevant segmentation metrics for quantitative result assessment. Compared with the DL alone methods, our proposed PnP framework was slightly inferior in MSE and PSNR. However, the power spectrum of the resulting images better matched that of full-dose images than that of DL denoised images. The resulting images supported higher accuracy in airway segmentation than DL denoised images for all the ten patients in the test set, more substantially on the airways with a cross-section smaller than 0.61cm$^2$, and outperformed the DL denoised images for 45 out of 50 lung lobes in lobar segmentation. Our PnP method proved to be significantly better at preserving the image texture, which translated to task-specific benefits in automated structure segmentation and detection.

eess.IV↗

DeepMCDose: A Deep Learning Method for Efficient Monte Carlo Beamlet Dose Calculation by Predictive Denoising in MR-Guided Radiotherapy

The next great leap toward improving treatment of cancer with radiation will require the combined use of online adaptive and magnetic resonance guided radiation therapy techniques with automatic X-ray beam orientation selection. Unfortunately, by uniting these advancements, we are met with a substantial expansion in the required dose information and consequential increase to the overall computational time imposed during radiation treatment planning, which cannot be handled by existing techniques for accelerating Monte Carlo dose calculation. We propose a deep convolutional neural network approach that unlocks new levels of acceleration and accuracy with regards to post-processed Monte Carlo dose results by relying on data-driven learned representations of low-level beamlet dose distributions instead of more limited filter-based denoising techniques that only utilize the information in a single dose input. Our method uses parallel UNET branches acting on three input channels before mixing latent understanding to produce noise-free dose predictions. Our model achieves a normalized mean absolute error of only 0.106% compared with the ground truth dose contrasting the 25.7% error of the under sampled MC dose fed into the network at prediction time. Our model's per-beamlet prediction time is ~220ms, including Monte Carlo simulation and network prediction, with substantial additional acceleration expected from batched processing and combination with existing Monte Carlo acceleration techniques. Our method shows promise toward enabling clinical practice of advanced treatment technologies.

physics.med-ph↗

Fully Automated Pancreas Segmentation with Two-stage 3D Convolutional Neural Networks

Due to the fact that pancreas is an abdominal organ with very large variations in shape and size, automatic and accurate pancreas segmentation can be challenging for medical image analysis. In this work, we proposed a fully automated two stage framework for pancreas segmentation based on convolutional neural networks (CNN). In the first stage, a U-Net is trained for the down-sampled 3D volume segmentation. Then a candidate region covering the pancreas is extracted from the estimated labels. Motivated by the superior performance reported by renowned region based CNN, in the second stage, another 3D U-Net is trained on the candidate region generated in the first stage. We evaluated the performance of the proposed method on the NIH computed tomography (CT) dataset, and verified its superiority over other state-of-the-art 2D and 3D approaches for pancreas segmentation in terms of dice-sorensen coefficient (DSC) accuracy in testing. The mean DSC of the proposed method is 85.99%.

cs.CV↗

Motion Compensated Dynamic MRI Reconstruction with Local Affine Optical Flow Estimation

This paper proposes a novel framework to reconstruct the dynamic magnetic resonance images (DMRI) with motion compensation (MC). Due to the inherent motion effects during DMRI acquisition, reconstruction of DMRI using motion estimation/compensation (ME/MC) has been studied under a compressed sensing (CS) scheme. In this paper, by embedding the intensity-based optical flow (OF) constraint into the traditional CS scheme, we are able to couple the DMRI reconstruction with motion field estimation. The formulated optimization problem is solved by a primal-dual algorithm with linesearch due to its efficiency when dealing with non-differentiable problems. With the estimated motion field, the DMRI reconstruction is refined through MC. By employing the multi-scale coarse-to-fine strategy, we are able to update the variables(temporal image sequences and motion vectors) and to refine the image reconstruction alternately. Moreover, the proposed framework is capable of handling a wide class of prior information (regularizations) for DMRI reconstruction, such as sparsity, low rank and total variation. Experiments on various DMRI data, ranging from in vivo lung to cardiac dataset, validate the reconstruction quality improvement using the proposed scheme in comparison to several state-of-the-art algorithms.

cs.CV↗

Fraction-variant beam orientation optimization for non-coplanar IMRT

Conventional beam orientation optimization (BOO) algorithms for IMRT assume that the same set of beam angles is used for all treatment fractions. In this paper we present a BOO formulation based on group sparsity that simultaneously optimizes non-coplanar beam angles for all fractions, yielding a fraction-variant (FV) treatment plan. Beam angles are selected by solving a multi-fraction FMO problem involving 500-700 candidate beams per fraction, with an additional group sparsity term that encourages most candidate beams to be inactive. The optimization problem is solved using the Fast Iterative Shrinkage-Thresholding Algorithm. Our FV BOO algorithm is used to create non-coplanar, five-fraction treatment plans for prostate and lung cases, as well as a non-coplanar 30-fraction plan for a head and neck case. A homogeneous PTV dose coverage is maintained in all fractions. The treatment plans are compared with fraction-invariant plans that use a fixed set of beam angles for all fractions. The FV plans reduced mean and max OAR dose on average by 3.3% and 3.7% of the prescription dose, respectively. Notably, mean OAR dose was reduced by 14.3% of prescription dose (rectum), 11.6% (penile bulb), 10.7% (seminal vesicle), 5.5% (right femur), 3.5% (bladder), 4.0% (normal left lung), 15.5% (cochleas), and 5.2% (chiasm). Max OAR dose was reduced by 14.9% of prescription dose (right femur), 8.2% (penile bulb), 12.7% (prox. bronchus), 4.1% (normal left lung), 15.2% (cochleas), 10.1% (orbits), 9.1% (chiasm), 8.7% (brainstem), and 7.1% (parotids). Meanwhile, PTV homogeneity defined as D95/D5 improved from .95 to .98 (prostate case) and from .94 to .97 (lung case), and remained constant for the head and neck case. Moreover, the FV plans are dosimetrically similar to conventional plans that use twice as many beams per fraction. Thus, FV BOO offers the potential to reduce delivery time for non-coplanar IMRT.

physics.med-ph↗

Fast non-coplanar beam orientation optimization based on group sparsity

The selection of beam orientations, which is a key step in radiation treatment planning, is particularly challenging for non-coplanar radiotherapy systems due to the large number of candidate beams. In this paper, we report progress on the group sparsity approach to beam orientation optimization, wherein beam angles are selected by solving a large scale fluence map optimization problem with an additional group sparsity penalty term that encourages most candidate beams to be inactive. The optimization problem is solved using an accelerated proximal gradient method, the Fast Iterative Shrinkage-Thresholding Algorithm (FISTA). We derive a closed-form expression for a relevant proximal operator which enables the application of FISTA. The proposed algorithm is used to create non-coplanar treatment plans for four cases (including head and neck, lung, and prostate cases), and the resulting plans are compared with clinical plans. The dosimetric quality of the group sparsity treatment plans is superior to that of the clinical plans. Moreover, the runtime for the group sparsity approach is typically about 5 minutes. Problems of this size could not be handled using the previous group sparsity method for beam orientation optimization, which was slow to solve much smaller coplanar cases. This work demonstrates for the first time that the group sparsity approach, when combined with an accelerated proximal gradient method such as FISTA, works effectively for non-coplanar cases with 500-800 candidate beams.

physics.med-ph↗