SearcharxivSearch

arXiv subjects

Kei Ieki

Publications and source records attributed to Kei Ieki.

5 recordsLinked to original sources

Combined Pre-Supernova Alert System with Kamland and Super-Kamiokande

Preceding a core-collapse supernova, various processes produce an increasing amount of neutrinos of all flavors characterized by mounting energies from the interior of massive stars. Among them, the electron antineutrinos are potentially detectable by terrestrial neutrino experiments such as KamLAND and Super-Kamiokande via inverse beta decay interactions. Once these pre-supernova neutrinos are observed, an early warning of the upcoming core-collapse supernova can be provided. In light of this, KamLAND and Super-Kamiokande, both located in the Kamioka mine in Japan, have been monitoring pre-supernova neutrinos since 2015 and 2021, respectively. Recently, we performed a joint study between KamLAND and Super-Kamiokande on pre-supernova neutrino detection. A pre-supernova alert system combining the KamLAND detector and the Super-Kamiokande detector was developed and put into operation, which can provide a supernova alert to the astrophysics community. Fully leveraging the complementary properties of these two detectors, the combined alert is expected to resolve a pre-supernova neutrino signal from a 15 M$_{\odot}$ star within 510 pc of the Earth, at a significance level corresponding to a false alarm rate of no more than 1 per century. For a Betelgeuse-like model with optimistic parameters, it can provide early warnings up to 12 hours in advance.

hep-ex

Prototype study of $0.1\%\,X_0$ and $\mathrm{MHz/cm^2}$ tolerant Resistive Plate Chamber with Diamond-Like Carbon electrodes

A novel Resistive Plate Chamber (RPC) was designed with Diamond-Like Carbon (DLC) electrodes and performance studies were carried out for 384$\,\mathrm{μm}$ gap configuration with a $2\,\mathrm{cm}\times2\,\mathrm{cm}$ prototype. The use of thin films coated with DLC enables an ultra-low mass design of $< 0.1\%\,X_0$ with up to a four-layer configuration. At the same time, 42% MIP efficiency, and 180 ps timing resolution per layer were achieved in a measurement performed under a $1\,\mathrm{MHz/cm^2}$ non-MIP charged particle beam. In addition, we propose a further improved design for a $20\,\mathrm{cm}$-scale detector that can achieve 90% four-layer efficiency in an even higher $4\,\mathrm{MHz/cm^2}$ beam. In this paper, we describe the detector design, present the results of performance measurements, and characterize the rate capability of the DLC-based RPCs with a performance projection for an improved design.

physics.ins-det

Development of ultra-low mass and high-rate capable RPC based on Diamond-Like Carbon electrodes for MEG II experiment

A new type of resistive plate chamber with thin-film electrodes based on diamond-like carbon is under development for background identification in the MEG II experiment. Installed in a low-momentum and high-intensity muon beam, the detector is required to have extremely low mass and a high rate capability. A single-layer prototype detector with 2 cm $\times$ 2 cm size was constructed and evaluated to have a high rate capability of 1 MHz/cm$^2$ low-momentum muons. For a higher rate capability and scalability of the detector size, the electrodes to supply high voltage were segmented at a 1 cm pitch by implementing a conductive pattern on diamond-like carbon. Using the new electrodes, a four-layer prototype detector was constructed and evaluated to have a 46% detection efficiency with only a single layer active at a rate of $\cal O$(10 kHz). The result with the new electrodes is promising to achieve the required detection efficiency of 90% at a rate of 4 MHz/cm$^2$ with all the layers active.

physics.ins-det

Development of high-rate capable and ultra-low mass Resistive Plate Chamber with Diamond-Like Carbon

A new type of resistive plate chamber (RPC) is under development using thin-film resistive electrodes based on diamond-like carbon (DLC). Planned to be put on the path of high-intensity low-momentum muon beam of the MEG II experiment, this detector is required to be high-rate capable and ultra-low mass. Using a prototype detector with 2 cm $\times$ 2 cm size and 0.1 % $X_0$ material budget, performance studies were conducted for MIP detection efficiency, timing resolution and high rate capability in low-momentum muon beam. In this paper, the measured performance is presented including the result with low-momentum muon beam at rate up to 1 $\mathrm{MHz/cm^2}$. Based on the result, the expected performance of the full-scale detector in the MEG~II experiment is also discussed.

physics.ins-det

The Search for $μ^+\to e^+ γ$ with 10$^{-14}$ Sensitivity: the Upgrade of the MEG Experiment

The MEG experiment took data at the Paul Scherrer Institute in the years 2009--2013 to test the violation of the lepton flavour conservation law, which originates from an accidental symmetry that the Standard Model of elementary particle physics has, and published the most stringent limit on the charged lepton flavour violating decay $μ^+ \rightarrow {\rm e}^+ γ$: BR($μ^+ \rightarrow {\rm e}^+ γ$) $<4.2 \times 10^{-13}$ at 90% confidence level. The MEG detector has been upgraded in order to reach a sensitivity of $6\times10^{-14}$. The basic principle of MEG II is to achieve the highest possible sensitivity using the full muon beam intensity at the Paul Scherrer Institute ($7\times10^{7}$ muons/s) with an upgraded detector. The main improvements are better rate capability of all sub-detectors and improved resolutions while keeping the same detector concept. In this paper, we present the current status of the preparation, integration and commissioning of the MEG II detector in the recent engineering runs.

hep-ex