SearcharxivSearch

arXiv subjects

Keigo Enya

Publications and source records attributed to Keigo Enya.

At least 19 recordsLinked to original sources

Japan's Possible Contributions for Coronagraph of the Habitable Worlds Observatory (HWO)

In this paper, we describe Japan's possible contributions for coronagraph of the Habitable Worlds Observatory (HWO) based on our independent study. We are considering to contribute to the HOW coronagraph by science and hardware, based on Japan's experience for the SPICA coronagraph instrument, contributions to the Nancy Grace Roman Space Telescope, and SCExAO for the Subaru telescope. Currently, hardware contributions of various scales, from large-scale to small components, are considered. As an example of the large-scale hardware case, the optical and mechanical layout of the entire infrared coronagraph is presented. Several individual high-contrast technologies are also briefly introduced, for which research is ongoing in Japan. In discussions, it is pointed out that both the inner working angle (IWA) and sensitivity are particularly critical for the NIR coronagraph. In this situation, dedicated observations of a small number of targets close to the solar system can be one of key science program in this situation, and designing consolidating science objectives, requirements, observation targets, and survey plans is important. It is essential to push the development of advanced coronagraphs that provide small IWAs. On the other hand, it is also necessary to prepare solutions that adopt more robust coronagraphs in parallel. How to coexist visible and NIR coronagraphs within constraints of volume, mass, budget etc. is an important issue. The international sharing for the coronagraph development should be carefully decided by international agreement. Although all of our studies may not be realized in contributions to the first generation of HWO instruments, we are considering Japan's multigenerational participation in the HWO to maximize outcomes of the HWO.

astro-ph.IM

Demonstrating Exoplanet Transit Photometry from Space with a 15-mm Aperture Optical Navigation Camera on Hayabusa2

Observations of exoplanet transits by small satellites have gained increasing attention for reducing detection biases. However, no unambiguous detection of an exoplanet has yet been demonstrated using optics with apertures smaller than 60 mm. Here, we investigated the detectability of exoplanet transits using the telescopic Optical Navigation Camera (ONC-T) onboard the Hayabusa2 spacecraft, which has an effective aperture of only 15 mm. We conducted transit observations of the hot Jupiters WASP-189 b and MASCARA-1 b, collecting data for ten and four events, respectively. The transit signal was detected with a signal-to-noise ratio (SNR) of 13 for WASP-189 b and 8 for MASCARA-1 b for each event. Stacking all events improved the SNR to 40 and 16, respectively. The transit mid-times of each event were measured with a precision of 6 minutes and were consistent with Transiting Exoplanet Survey Satellite (TESS) data to within 2 minutes. The planet-to-star radius ratio was determined with an absolute precision of 0.004 (6% relative) and agreed with TESS results to within 0.002 (3% relative). The recent ONC-T and TESS data enabled an update to the planetary ephemerides. We report a 4 sigma discrepancy between the updated orbital period of MASCARA-1 b and previously reported values. ONC-T sets a new record for the smallest-aperture instrument to detect an exoplanet transit from space, advancing the frontier of exoplanet science with miniature instrumentation. Our results suggest that optics as small as ONC-T may be capable of detecting transiting long-period Jupiters: a population that remains underrepresented in current surveys.

astro-ph.EP

Reverberation Measurements of the Inner Radii of the Dust Tori in Quasars

We present the results of a dust-reverberation survey of quasars at redshifts z<0.6. We found a delayed response of the K-band flux variation after the optical flux variation in 25 out of 31 targets, and obtained the lag time between them for 22 targets. Combined with the results for nearby Seyfert galaxies, we provide the largest homogeneous collection of K-band dust-reverberation data for 36 type 1 active galactic nuclei (AGNs). This doubles the sample and includes the most distant AGN and the largest lag so far measured. We estimated the optical luminosity of the AGN component of each target using three different methods: spectral decomposition, the flux-variation-gradient method, and image decomposition. We found a strong correlation between the reverberation radius for the innermost dust torus and the optical luminosity over a range of approximately four orders of magnitude in luminosity, as is already known for Seyfert galaxies. We estimated the luminosity distances of the AGNs based on their dust-reverberation lags, and found that the data in the redshift-distance diagram are consistent with the current standard estimates of the cosmological parameters. We also present the radius-luminosity relations for isotropic luminosity indicators such as the hard X-ray (14--195 keV), [OIV] 25.89 um, and mid-infrared (12 um) continuum luminosities, which are applicable to obscured AGNs.

astro-ph.GA

Stellar Imaging Coronagraph and Exoplanet Coronal Spectrometer: Two Additional Instruments for Exoplanet Exploration Onboard The WSO-UV 1.7 Meter Orbital Telescope

The World Space Observatory for Ultraviolet (WSO-UV) is an orbital optical telescope with a 1.7 m-diameter primary mirror currently under development. The WSO-UV is aimed to operate in the 115-310 nm UV spectral range. Its two major science instruments are UV spectrographs and a UV imaging field camera with filter wheels. The WSO-UV project is currently in the implementation phase, with a tentative launch date in 2023. Recently, two additional instruments devoted to exoplanets have been proposed for WSO-UV, which are the focus of this paper. UVSPEX, a UV-Spectrograph for Exoplanets, aims to determine atomic hydrogen and oxygen abundance in the exospheres of terrestrial exoplanets. The spectral range is 115-130 nm which enables simultaneous measurement of hydrogen and oxygen emission intensities during an exoplanet transit. Study of exosphere transit photometric curves can help differentiate among different types of rocky planets. The exospheric temperature of an Earth-like planet is much higher than that of a Venus-like planet, because of the low mixing ratio of the dominant coolant (CO2) in the upper atmosphere of the former, which causes a large difference in transit depth at the oxygen emission line. Thus, whether the terrestrial exoplanet is Earth-like, Venus-like, or other can be determined. SCEDI, a Stellar Coronagraph for Exoplanet Direct Imaging is aimed to directly detect the starlight reflected from exoplanets orbiting their parent stars or from the stellar vicinity including circumstellar discs, dust, and clumps. SCEDI will create an achromatic (optimized to 420-700 nm wavelength range), high-contrast stellocentric coronagraphic image of a circumstellar vicinity. The two instruments: UVSPEX and SCEDI, share common power and control modules. The present communication outlines the science goals of both proposed instruments and explains some of their engineering features.

astro-ph.IM

Science Objectives of the Ganymede Laser Altimeter (GALA) for the JUICE Mission

Laser altimetry is a powerful tool for addressing the major objectives of planetary physics and geodesy, and have been applied in planetary explorations of the Moon, Mars, Mercury, and the asteroids Eros, and Itokawa. The JUpiter Icy Moons Explorer (JUICE), led by European Space Agency (ESA), has started development to explore the emergence of habitable worlds around gas giants. The Ganymede Laser Altimeter (GALA) will be the first laser altimeter for icy bodies, and will measure the shape and topography of the large icy moons of Jupiter, (globally for Ganymede, and using flyby ground-tracks for Europa and Callisto). Such information is crucial for understanding the formation of surface features and can tremendously improve our understanding of the icy tectonics. In addition, the GALA will infer the presence or absence of a subsurface ocean by measuring the tidal and rotational responses. Furthermore, it also improves the accuracy of gravity field measurements reflecting the interior structure, collaborating with the radio science experiment. In addition to range measurements, the signal strength and the waveform of the laser pulses reflected from the moon's surface contain information about surface reflectance at the laser wavelength and small scale roughness. Therefore we can infer the degrees of chemical and physical alterations, e.g., erosion, space weathering, compaction and deposition of exogenous materials, through GALA measurements without being affected by illumination conditions. JUICE spacecraft carries ten science payloads including GALA. They work closely together in a synergistic way with GALA being one of the key instruments for understanding the evolution of the icy satellites Ganymede, Europa, and Callisto.

astro-ph.EP

Laboratory demonstration of a cryogenic deformable mirror for wavefront correction of space-borne infrared telescopes

This paper demonstrates a cryogenic deformable mirror (DM) with 1,020 actuators based on micro-electrical mechanical systems (MEMS) technology. Cryogenic space-borne infrared telescopes can experience a wavefront error due to a figure error of their mirror surface, which makes the imaging performance worse. For on-orbit wavefront correction as one solution, we developed a MEMS-processed electro-static DM with a special surrounding structure for use under the cryogenic temperature. We conducted a laboratory demonstration of its operation in three cooling cycles between 5 K and 295 K. Using a laser interferometer, we detected the deformation corresponding to the applied voltages under the cryogenic temperature for the first time. The relationship between voltages and displacements was qualitatively expressed by the quadratic function, which is assumed based on the principle of electro-static DMs. We also found that it had a high operating repeatability of a few nm RMS and no significant hysteresis. Using the measured values of repeatability, we simulated the improvement of PSF by wavefront correction with our DM. These results show that our developed DM is effective in improving imaging performance and PSF contrast of space-borne infrared telescopes.

astro-ph.IM

Calibration of AGN Reverberation Distance Measurements

In Yoshii et al. (2014), we described a new method for measuring extragalactic distances based on dust reverberation in active galactic nuclei (AGNs), and we validated our new method with Cepheid variable stars. In this paper, we validate our new method with Type Ia supernovae (SNe Ia) which occurred in two of the AGN host galaxies during our AGN monitoring program: SN 2004bd in NGC 3786 and SN 2008ec in NGC 7469. Their multicolor light curves were observed and analyzed using two widely accepted methods for measuring SN distances, and the distance moduli derived are $μ=33.47\pm 0.15$ for SN 2004bd and $33.83\pm 0.07$ for SN 2008ec. These results are used to obtain independently the distance measurement calibration factor, $g$. The $g$ value obtained from the SN Ia discussed in this paper is $g_{\rm SN} = 10.61\pm 0.50$ which matches, within the range of 1$σ$ uncertainty, $g_{\rm DUST} = 10.60$, previously calculated ab initio in Yoshii et al. (2014). Having validated our new method for measuring extragalactic distances, we use our new method to calibrate reverberation distances derived from variations of H$β$ emission in the AGN broad line region (BLR), extending the Hubble diagram to $z\approx 0.3$ where distinguishing between cosmologies is becoming possible.

astro-ph.GA

Experimental demonstration of binary shaped pupil mask coronagraphs for telescopes with obscured pupils

We present the fabrication and experimental demonstration of three free-standing binary shaped pupil mask coronagraphs, which are applicable for telescopes with partially obscured pupils. Three masks, designed to be complementary (labeled Mask-A, Mask-B, and Mask-C), were formed in 5 micron thick nickel. The design of Mask-A is based on a one-dimensional barcode mask. The design principle of Mask-B is similar, but has a smaller inner working angle and a lower contrast than Mask-A. Mask-C is based on a concentric ring mask and provides the widest dark region and a symmetric point spread function. Mask-A and Mask-C were both designed to produce a flexibly tailored dark region (i.e., non-uniform contrast). The contrast was evaluated using a light source comprising a broadband super-luminescent light-emitting diode with a center wavelength of 650 nm, and the measurements were carried out in a large vacuum chamber. Active wavefront control was not applied in this work. The coronagraphic images obtained by experiment were mostly consistent with the designs. The contrast of Mask-A within the ranges 3.3 - 8 lambda/D and 8 - 12 lambda/D was ~10^{-4} - 10^{-7} and ~10^{-7}, respectively, where lambda is the wavelength and D is the pupil diameter. The contrast close to the center of Mask-B was ~10^{-4} and that of Mask-C over an extended field of view (5 - 25 lambda/D) was ~10^{-5} - 10^{-6}. The effect of tilting the masks was investigated, and found to be irrelevant at the ~10^{-7} contrast level. Therefore the masks can be tilted to avoid ghosting. These high-contrast free-standing masks have the potential to enable coronagraphic imaging over a wide wavelength range using both ground-based and space-borne general-purpose telescopes with pupil structures not specifically designed for coronagraphy.

astro-ph.IM

Coronagraphic demonstration experiment using aluminum mirrors for space infrared astronomical observations

For future space infrared astronomical coronagraphy, we perform experimental studies on the application of aluminum mirrors to a coronagraph. Cooled reflective optics is required for broad-band mid-infrared observations in space, while high-precision optics is required for coronagraphy. For the coronagraph instrument originally proposed for the next-generation infrared astronomical satellite project SPICA (SCI: SPICA Coronagraph Instrument), we fabricated and evaluated the optics consisting of high-precision aluminum off-axis mirrors with diamond-turned surfaces, and conducted a coronagraphic demonstration experiment using the optics with a coronagraph mask. We first measured the wave front errors (WFEs) of the aluminum mirrors with a He-Ne Fizeau interferometer to confirm that the power spectral densities of the WFEs satisfy the SCI requirements. Then we integrated the mirrors into an optical system and evaluated the overall performance of the system. As a result, we estimate the total WFE of the optics to be 33 nm (rms), each mirror contributing 10-20 nm (rms) for the central 14 mm area of the optics, and obtain a contrast of 10^(-5.4) as a coronagraph in the visible light. At a wavelength of 5 um, the coronagraphic system is expected to achieve a contrast of ~10^(-7) based on our model calculation with the measured optical performance. Thus our experiment demonstrates that aluminum mirror optics is applicable to a highly WFE-sensitive instrument such as a coronagraph in space.

astro-ph.IM

Development of a Fine Grating on ZnS for a Wideband Spectral Disperser in Characterizing Exoplanets using Space-borne Telescopes

We present the fabrication and optical testing of a fine grating on a ZnS substrate to be used as a wideband infrared spectral disperser and for which the primary application is measurement of the composition of the atmospheres of transiting exoplanets using space-borne infrared astronomical telescopes. A grating with a blaze angle of 2.1 deg. and pitch of 166.667 midron was constructed on a roughly flat 10 mm x 10 mm substrate with a maximum thickness of 1 mm. To obtain high accuracy, the sample was fabricated on a ZnS monocrystal using a high performance processing machine at Canon Inc. The surface roughness measured with a microscope interferometer was 2.6 nm rms. The shape of the fabricated grating edges was examined with a scanning electron microscope. The diffraction efficiency was evaluated by optical experiments at λ = 633 nm, 980 nm, and 1550 nm, and compared with the efficiencies calculated using a Fourier Modal Method. The results showed that the differences between the diffraction efficiencies obtained from experiment and by calculation were between just 0.9 % and 2.4 %. We concluded that the quality of the fabricated ZnS grating was sufficiently high to provide excellent diffraction efficiency for use in the infrared wavelength region. We also present the design of a spectral disperser in CdTe for future more advanced performance.

astro-ph.IM

AKARI/IRC 18 Micron Survey of Warm Debris Disks

Context. Little is known about the properties of the warm (Tdust >~ 150 K) debris disk material located close to the central star, which has a more direct link to the formation of terrestrial planets than the low temperature debris dust that has been detected to date. Aims. To discover new warm debris disk candidates that show large 18 micron excess and estimate the fraction of stars with excess based on the AKARI/IRC Mid-Infrared All-Sky Survey data. Methods. We have searched for point sources detected in the AKARI/IRC All-Sky Survey, which show a positional match with A-M dwarf stars in the Tycho-2 Spectral Type Catalogue and exhibit excess emission at 18 micron compared to that expected from the Ks magnitude in the 2MASS catalogue. Results. We find 24 warm debris candidates including 8 new candidates among A-K stars. The apparent debris disk frequency is estimated to be 2.8 +/- 0.6%. We also find that A stars and solar-type FGK stars have different characteristics of the inner component of the identified debris disk candidates --- while debris disks around A stars are cooler and consistent with steady-state evolutionary model of debris disks, those around FGK stars tend to be warmer and cannot be explained by the steady-state model.

astro-ph.EP

Comparative study of manufacturing techniques for coronagraphic binary pupil masks: masks on substrates and free-standing masks

We present a comparative study of the manufacture of binary pupil masks for coronagraphic observations of exoplanets. A checkerboard mask design, a type of binary pupil mask design, was adopted, and identical patterns of the same size were used for all the masks in order that we could compare the differences resulting from the different manufacturing methods. The masks on substrates had aluminum checkerboard patterns with thicknesses of 0.1/0.2/0.4/0.8/1.6$μ$m constructed on substrates of BK7 glass, silicon, and germanium using photolithography and chemical processes. Free-standing masks made of copper and nickel with thicknesses of 2/5/10/20$μ$m were also realized using photolithography and chemical processes, which included careful release from the substrate used as an intermediate step in the manufacture. Coronagraphic experiments using a visible laser were carried out for all the masks on BK7 glass substrate and the free-standing masks. The average contrasts were 8.4$\times10^{-8}$, 1.2$\times10^{-7}$, and 1.2$\times10^{-7}$ for the masks on BK7 substrates, the free-standing copper masks, and the free-standing nickel masks, respectively. No significant correlation was concluded between the contrast and the mask properties. The high contrast masks have the potential to cover the needs of coronagraphs for both ground-based and space-borne telescopes over a wide wavelength range. Especially, their application to the infrared space telescope, SPICA, is appropriate.

astro-ph.IM

Wideband Infrared Spectrometer for Characterization of Transiting Exoplanets with Space Telescopes

This paper presents a conceptual design for a spectrometer designed specifically for characterizing transiting exoplanets with space-borne infrared telescopes. The design adopting cross-dispersion is intended to be simple, compact, highly stable, and has capability of simultaneous coverage over a wide wavelength region with high throughput. Typical wavelength coverage and spectral resolving power is 1-13 micron with a spectral resolving power of ~ a few hundred, respectively. The baseline design consists of two detectors, two prisms with a dichroic coating and microstructured grating surfaces, and three mirrors. Moving parts are not adopted. The effect of defocusing is evaluated for the case of a simple shift of the detector, and anisotropic defocusing to maintain the spectral resolving power. Variations in the design and its application to planned missions are also discussed.

astro-ph.IM

Two Upper Limits on the Rossiter-McLaughlin Effect, with Differing Implications: WASP-1 has a High Obliquity and WASP-2 is Indeterminate

We present precise radial-velocity measurements of WASP-1 and WASP-2 throughout transits of their giant planets. Our goal was to detect the Rossiter-McLaughlin (RM) effect, the anomalous radial velocity observed during eclipses of rotating stars, which can be used to study the obliquities of planet-hosting stars. For WASP-1 a weak signal of a prograde orbit was detected with ~2sigma confidence, and for WASP-2 no signal was detected. The resulting upper bounds on the RM amplitude have different implications for these two systems, because of the contrasting transit geometries and the stellar types. Because WASP-1 is an F7V star, and such stars are typically rapid rotators, the most probable reason for the suppression of the RM effect is that the star is viewed nearly pole-on. This implies the WASP-1 star has a high obliquity with respect to the edge-on planetary orbit. Because WASP-2 is a K1V star, and is expected to be a slow rotator, no firm conclusion can be drawn about the stellar obliquity. Our data and our analysis contradict an earlier claim that WASP-2b has a retrograde orbit, thereby revoking this system's status as an exception to the pattern that cool stars have low obliquities.

astro-ph.EP

Multi-Color Coronagraph Experiment in a Vacuum Testbed with a Binary Shaped Pupil Mask

We conducted a number of multi-band coronagraph experiments using a vacuum chamber and a binary-shaped pupil mask which in principle should work at all wavelengths, in the context of the research and development on a coronagraph to observe extra-solar planets (exoplanets) directly. The aim of this work is to demonstrate that subtraction of Point Spread Function (PSF) and multi-band experiments using a binary-shaped pupil mask coronagraph would help improve the contrast in the observation of exoplanets. A checkerboard mask, a kind of binary-shaped pupil mask, was used. We improved the temperature stability by installing the coronagraph optics in a vacuum chamber, controlling the temperature of the optical bench, and covering the vacuum chamber with thermal insulation layers. We evaluated how much the PSF subtraction contributes to the high contrast observation by subtracting the images obtained through the coronagraph. We also carried out multi- band experiments in order to demonstrate a more realistic observation using Super luminescent Light Emitting Diodes (SLEDs) with center wavelengths of 650nm, 750nm, 800nm and 850nm. A contrast of 2.3x10-7 was obtained for the raw coronagraphic image and a contrast of 1.3x10-9 was achieved after PSF subtraction with a He-Ne laser at 632.8nm wavelength. Thus, the contrast was improved by around two orders of magnitude from the raw contrast by subtracting the PSF. We achieved contrasts of 3.1x10-7, 1.1x10-6, 1.6x10-6 and 2.5x10-6 at the bands of 650nm, 750nm, 800nm and 850nm, respectively, in the multi-band experiments. The results show that contrast within each of the wavelength bands was significantly improved compared with non-coronagraphic optics. We demonstrated PSF subtraction is potentially beneficial for improving contrast of the coronagraph, and this coronagraph produces a significant improvement in contrast with multi-band light sources.

astro-ph.IM

Constraint on the giant planet production by core accretion

The issue of giant planet formation by core instability (CI) far from the central star is rather controversial because the growth of massive solid core necessary for triggering the CI can take longer than the lifetime of the protoplanetary disk. In this work we assess the range of separations at which the CI may operate by (1) allowing for arbitrary (physically meaningful) rate of planetesimal accretion by the core and (2) properly taking into account the dependence of the critical mass for the CI on the planetesimal accretion luminosity. This self-consistent approach distinguishes our work from similar studies in which only a specific planetesimal accretion regime was explored and/or the critical core mass was fixed at some arbitrary level. We demonstrate that the largest separation at which the CI can occur within 3 Myr corresponds to the surface density of solids in the disk higher than 0.1 g cm^{-2} and is 40-50 AU in the minimum mass Solar nebula. This limiting separation is achieved when the planetesimal accretion proceeds at the fastest possible rate, even though the high associated accretion luminosity increases the critical core mass delaying the onset of the CI. Our constraints are independent of the mass of the central star and vary only weakly with the core density and its atmospheric opacity. We also discuss various factors which can strengthen or weaken our limits on the operation of the CI.

astro-ph.EP

SPICA infrared coronagraph for the direct observation of exo-planets

We present a MIR coronagraph to target the direct observation of extrasolar planets for SPICA, in which a coronagraph is currently regarded as an option of the focal plane instruments. The primary target of the SPICA coronagraph is the direct observation of Jovian exo-planets. A strategy of the baseline survey and the specifications for the coronagraph instrument for the survey are introduced together. The main wavelengths and the contrast required for the observations are 3.5-27um, and 10^{-6}, respectively.Laboratory experiments were performed with a visible laser to demonstrate the principles of the coronagraphs. In an experiment using binary-shaped pupil coronagraphs, a contrast of 6.7x10^{-8} was achieved, as derived from the linear average in the dark region and the core of the PSF. A coronagraph by a binary-shaped pupil mask is a baseline solution for SPICA because of its feasibility and robustness. On the other hand, a laboratory experiment of the phase induced amplitude apodization/binary-mask hybrid coronagraph has been executed to obtain an option of higher performance, and a contrast of 6.5x10^{-7} was achieved with active wavefront control.Potentially important by-product of the instrument, transit monitoring for characteization of exo-planets, is also described. We also present recent progress of technology on a design of a binary-shaped pupil mask for the actual pupil of SPICA, PSF subtraction, the development of free-standing binary masks, a vacuum chamber, and a cryogenic deformable mirror. Considering SPICA to be an essential platform for coronagraphs and the progress of key technologies, we propose to develop a mid-infrared coronagraph instrument for SPICA and to perform the direct observation of exo-planets with it.

astro-ph.EP

Long-Term Optical Continuum Color Variability of Nearby Active Galactic Nuclei

We examine whether the spectral energy distribution of optical continuum emission of active galactic nuclei (AGNs) changes during flux variation, based on accurate and frequent monitoring observations of 11 nearby Seyfert galaxies and QSOs carried out in the B, V, and I bands for seven years by the MAGNUM telescope. The multi-epoch flux data in any two different bands obtained on the same night show a very tight linear flux to flux relationship for all target AGNs. The flux of the host galaxy within the photometric aperture is carefully estimated by surface brightness fitting to available high-resolution HST images and MAGNUM images. The flux of narrow emission lines in the photometric bands is also estimated from available spectroscopic data. We find that the non-variable component of the host galaxy plus narrow emission lines for all target AGNs is located on the fainter extension of the linear regression line of multi-epoch flux data in the flux to flux diagram. This result strongly indicates that the spectral shape of AGN continuum emission in the optical region does not systematically change during flux variation. The trend of spectral hardening that optical continuum emission becomes bluer as it becomes brighter, which has been reported by many studies, is therefore interpreted as the domination of the variable component of the nearly constant spectral shape of an AGN as it brightens over the non-variable component of the host galaxy plus narrow lines, which is usually redder than AGN continuum emission.

astro-ph.CO