SearcharxivSearch

arXiv subjects

Keith A. Lidke

Publications and source records attributed to Keith A. Lidke.

3 recordsLinked to original sources

Earth's field diamond vector magnetometry with isotropic magnetic flux concentrators

Vector magnetometers based on the optically detected magnetic resonance (ODMR) of nitrogen-vacancy centers in diamond are being developed for applications such as navigation and geomagnetism. However, at low magnetic fields, such as that on Earth (~50 μT), diamond magnetometers suffer from spectral congestion whereby ODMR peaks are not easily resolved. Here, we experimentally investigate a potential solution of using an isotropic, three-dimensional magnetic flux concentrator to amplify Earth's field without altering its direction. The concentrator consists of six ferrite cones, in a face-centered cubic arrangement, centered about a diamond. We vary the direction of a 50 μT applied field and record and fit the resulting ODMR spectra. By comparing the fitted fields to those of a reference fluxgate magnetometer, we characterize the angular response of the diamond magnetometer and quantify absolute errors in the field magnitude and angle. We find that the enhancement factor is nearly isotropic, with a mean of 19.05 and a standard deviation of 0.16, when weighted by solid angle coverage. Gradient broadening of the ODMR lines is sufficiently small that the spectra are well resolved for nearly all field directions, alleviating spectral congestion. For ~98% of the total 4π solid angle, Cramér-Rao lower bounds for magnetic field estimation uncertainty are within a factor of 2 of those of the fully-resolved case, indicating minimal deadzones. We track the stability of the magnetometer over six hours and observe variations less than or approximately 40 nT/hour, limited by temperature drift. Our study presents a new route for diamond vector magnetometry at Earth's field, with potential applications in geomagnetic surveys, anomaly detection, and navigation.

physics.ins-det

Calibrating photon counts from a single image

Current methods for detector gain calibration require acquisition of tens of special calibration images. Here we propose a method that obtains the gain from the actual image for which the photon count is desired by quantifying out-of-band information. We show on simulation and experimental data that our much simpler procedure, which can be retroactively applied to any image, is comparable in precision to traditional gain calibration procedures.

physics.ins-det

Estimation of the Diffusion Constant from Intermittent Trajectories with Variable Position Uncertainties

The movement of a particle described by Brownian motion is quantified by a single parameter, $D$, the diffusion constant. The estimation of $D$ from a discrete sequence of noisy observations is a fundamental problem in biological single particle tracking experiments since it can report on the environment and/or the state of the particle itself via hydrodynamic radius. Here we present a method to estimate $D$ that takes into account several effects that occur in practice, that are important for correct estimation of $D$, and that have hitherto not been combined together for estimation of $D$. These effects are motion blur from finite integration time of the camera, intermittent trajectories, and time-dependent localization uncertainty. Our estimation procedure, a maximum likelihood estimation, follows directly from the likelihood expression for a discretely observed Brownian trajectory that explicitly includes these effects. The manuscript begins with the formulation of the likelihood expression and then presents three methods to find the exact solution. Each method has its own advantages in either computational robustness, theoretical insight, or the estimation of hidden variables. We then compare our estimator to previously published estimators using a squared log loss function to demonstrate the benefit of including these effects.

q-bio.SC