SearcharxivSearch

arXiv subjects

Ken Suzuki

Publications and source records attributed to Ken Suzuki.

17 recordsLinked to original sources

Feasibility demonstration of a high-momentum, high-purity muon beamline at the J-PARC Hadron Experimental Facility

We have established and characterized a novel high-purity muon beam delivery scheme, designated as $\mu$20, at the high-momentum hadron beamline (B-line) of the J-PARC Hadron Experimental Facility. This scheme delivers tertiary muons produced via the in-flight backward decays of secondary pions in the straight section of the beamline, inherently suppressing parent hadron contamination. In a systematic performance evaluation, the muon beam achieved a standalone intensity of $1.7\times10{^3}$ particles/spill with a spatial spread (standard deviation, $\sigma$) of approximately 15 mm at the downstream detector position. A systematic attenuation analysis utilizing an iron absorber verified a high muon purity of 98.0$\pm$0.6% for the 3 GeV/$c$ muon beam mode. Crucially, this work marks the first successful feasibility study of a high-momentum and high-purity muon beamline operation at an experimental facility in Japan.

physics.acc-ph

Revealing Polymorph-Specific Transduction in WO$_3$ during Acetone Sensing

Polymorphs are distinct structural forms of the same compound and offer unique opportunities to tailor material properties without altering chemical composition. In particular, the polymorphs of WO$_3$ have been widely explored for their molecular sensing performance; yet, the mechanistic aspects behind their different chemoresistive properties have remained elusive or poorly understood. Here, we highlight the energetic allocation of transferred charge as a critical aspect for chemoresistive response generation, providing a new perspective beyond more conventional net-transfer metrics, which are usually deployed to investigate gas-solid interactions. To this, we combined operando work function, chemisorption analysis, and in situ spectroscopy with density functional theory calculations on the example of acetone. Both gamma- and $\varepsilon$-WO$_3$ exhibit comparable surface-level activation of acetone, mediated by electron-deficient, coordinatively unsaturated tungsten sites. However, only $\varepsilon$-WO$_3$ stabilizes analyte-induced electronic states derived from W(5d) orbitals lying just below the conduction band - an energetically favourable region for conductivity modulation under operating conditions. While being associated with marginal work function shifts, these states reflect deeper subsurface electronic rearrangements that may underlie the $\varepsilon$-WO$_3$'s superior transduction efficiency despite similar receptor chemistry. Our results offer a new framework for rational transducer development rooted in intrinsic electronic structure.

cond-mat.mtrl-sci

Strong, Accurate, and Low-Cost Robot Manipulator

This paper presents Forte, a fully 3D-printable, 6-DoF robotic arm designed to achieve near industrial-grade performance - 0.63 kg payload, 0.467 m reach, and sub-millimeter repeatability - at a material cost under $215. As an accessible robot for broad applications across classroom education to AI experiments, Forte pushes forward the performance limitations of existing low-cost educational arms. We introduce a cost-effective mechanical design that combines capstan-based cable drives, timing belts, simple tensioning mechanisms, and lightweight 3D-printed structures, along with topology optimization for structural stiffness. Through careful drivetrain engineering, we minimize backlash and maintain control fidelity without relying on high-power electronics or expensive manufacturing processes. Experimental validation demonstrates that Forte achieves high repeatability and load capacity, offering a compelling robotic platform for both classroom instruction and advanced robotics research.

cs.RO

Propagational Proxy Voting

This paper proposes a voting process in which voters allocate fractional votes to their expected utility in different domains: over proposals, other participants, and sets containing proposals and participants. This approach allows for a more nuanced expression of preferences by calculating the result and relevance within each node. We modeled this by creating a voting matrix that reflects their preference. We use absorbing Markov chains to gain the consensus, and also calculate the influence within the participating nodes. We illustrate this method in action through an experiment with 69 students using a budget allocation topic.

cs.SI

Lessons Learned from Developing a Human-Centered Guide Dog Robot for Mobility Assistance

While guide dogs offer essential mobility assistance, their high cost, limited availability, and care requirements make them inaccessible to most blind or low vision (BLV) individuals. Recent advances in quadruped robots provide a scalable solution for mobility assistance, but many current designs fail to meet real-world needs due to a lack of understanding of handler and guide dog interactions. In this paper, we share lessons learned from developing a human-centered guide dog robot, addressing challenges such as optimal hardware design, robust navigation, and informative scene description for user adoption. By conducting semi-structured interviews and human experiments with BLV individuals, guide-dog handlers, and trainers, we identified key design principles to improve safety, trust, and usability in robotic mobility aids. Our findings lay the building blocks for future development of guide dog robots, ultimately enhancing independence and quality of life for BLV individuals.

cs.RO

StaccaToe: A Single-Leg Robot that Mimics the Human Leg and Toe

We introduce StaccaToe, a human-scale, electric motor-powered single-leg robot designed to rival the agility of human locomotion through two distinctive attributes: an actuated toe and a co-actuation configuration inspired by the human leg. Leveraging the foundational design of HyperLeg's lower leg mechanism, we develop a stand-alone robot by incorporating new link designs, custom-designed power electronics, and a refined control system. Unlike previous jumping robots that rely on either special mechanisms (e.g., springs and clutches) or hydraulic/pneumatic actuators, StaccaToe employs electric motors without energy storage mechanisms. This choice underscores our ultimate goal of developing a practical, high-performance humanoid robot capable of human-like, stable walking as well as explosive dynamic movements. In this paper, we aim to empirically evaluate the balance capability and the exertion of explosive ground reaction forces of our toe and co-actuation mechanisms. Throughout extensive hardware and controller development, StaccaToe showcases its control fidelity by demonstrating a balanced tip-toe stance and dynamic jump. This study is significant for three key reasons: 1) StaccaToe represents the first human-scale, electric motor-driven single-leg robot to execute dynamic maneuvers without relying on specialized mechanisms; 2) our research provides empirical evidence of the benefits of replicating critical human leg attributes in robotic design; and 3) we explain the design process for creating agile legged robots, the details that have been scantily covered in academic literature.

cs.RO

Chiral symmetry restoration at high matter density observed in pionic atoms

Modern theories of physics tell that the vacuum is not an empty space. Hidden in the vacuum is a structure of anti-quarks $\bar{q}$ and quarks $q$. The $\bar{q}$ and $q$ pair has the same quantum number as the vacuum and condensates in it since the strong interaction of the quantum chromodynamics (QCD) is too strong to leave it empty. The $\bar{q}q$ condensation breaks the chiral symmetry of the vacuum. The expectation value $<\bar{q}q>$ is an order parameter. For higher temperature or higher matter-density, $|<\bar{q}q>|$ decreases reflecting the restoration of the symmetry. In contrast to these clear-cut arguments, experimental evidence is so far limited. First of all, the $\bar{q}q$ is nothing but the vacuum itself. It is neither visible nor perceptible. In this article, we unravel this invisible existence by high precision measurement of pionic atoms, $π^-$-meson-nucleus bound systems. Using the $π^-$ as a probe, we demonstrate that $|<\bar{q}q>|$ is reduced in the nucleus at 58% of the normal nuclear density by a factor of 77 $\pm$ 2% compared with that in the vacuum. This reduction indicates that the chiral symmetry is partially restored due to the extremely high density of the nucleus. The present experimental result clearly exhibits the existence of the hidden structure, the chiral condensate, in the vacuum.

nucl-ex

System Configuration and Navigation of a Guide Dog Robot: Toward Animal Guide Dog-Level Guiding Work

A robot guide dog has compelling advantages over animal guide dogs for its cost-effectiveness, potential for mass production, and low maintenance burden. However, despite the long history of guide dog robot research, previous studies were conducted with little or no consideration of how the guide dog handler and the guide dog work as a team for navigation. To develop a robotic guiding system that is genuinely beneficial to blind or visually impaired individuals, we performed qualitative research, including interviews with guide dog handlers and trainers and first-hand blindfold walking experiences with various guide dogs. Grounded on the facts learned from vivid experience and interviews, we build a collaborative indoor navigation scheme for a guide dog robot that includes preferred features such as speed and directional control. For collaborative navigation, we propose a semantic-aware local path planner that enables safe and efficient guiding work by utilizing semantic information about the environment and considering the handler's position and directional cues to determine the collision-free path. We evaluate our integrated robotic system by testing guide blindfold walking in indoor settings and demonstrate guide dog-like navigation behavior by avoiding obstacles at typical gait speed ($0.7 \mathrm{m/s}$).

cs.RO

Efficiency and uniformity measurements of a light concentrator in combination with a SiPM array

A position sensitive Cherenkov detector was built, consisting of 64 SiPMs with an active area of 3x3 mm^2 and a pixel size of 100x100 μm^2. The sensitive area is increased by a light concentrator which consists of 64 pyramid-shaped funnels. These funnels have an entrance area of 7x7 mm^2 and an exit area of 3x3 mm^2, guaranteeing a sufficient position resolution e.g. for the barrel DIRC detector of the PANDA experiment at FAIR. The efficiency and uniformity of the light concentrator in combination with the SiPM array was tested by scanning the array in two dimensions, using a pulsed light beam. Results of these tests and comparison with simulations are given here.

physics.ins-det

New Approaches for Improvement of TOF-PET

We present results of simulations on the influence of photon propagation and the Cherenkov effect on the time resolution of LSO:Ce scintillators. The influence of the scintillator length on the coincidence time resolution is shown. Furthermore, the impact of the depth of interaction on the time resolution, the light output and the arrival time distribution at the photon detector is simulated and it is shown how these information can be used for time walk correction.

physics.ins-det

The K1.8BR spectrometer system at J-PARC

A new spectrometer system was designed and constructed at the secondary beam line K1.8BR in the hadron hall of J-PARC to investigate $\bar K N$ interactions and $\bar K$-nuclear bound systems. The spectrometer consists of a high precision beam line spectrometer, a liquid $^3$He/$^4$He/D$_2$ target system, a Cylindrical Detector System that surrounds the target to detect the decay particles from the target region, and a neutron time-of-flight counter array located $\sim$15 m downstream from the target position. Details of the design, construction, and performance of the detector components are described.

physics.ins-det

Spectroscopy of eta' mesic nuclei with (p,d) reaction

We are going to perform an inclusive spectroscopy experiment of eta' mesic nuclei with the 12C(p,d) reaction to study in-medium properties of the eta' meson. In nuclear medium, the eta' meson mass may be reduced due to partial restoration of chiral symmetry. In case of sufficiently large mass reduction and small absorption width of eta' at normal nuclear density, peak structures of eta' mesic states in 11C will be observed near the eta' emission threshold even in an inclusive spectrum. The experiment will be carried out at GSI with proton beam supplied by SIS using FRS as a spectrometer. The detail of the experiment is described.

nucl-ex

Spectroscopy of eta'-nucleus bound states at GSI-SIS

The eta' meson mass may be reduced due to partial restoration of chiral symmetry. If this is the case, an eta'-nucleus system may form a nuclear bound state. We plan to carry out a missing-mass spectroscopy with the 12C(p,d) reaction at GSI-SIS. Peak structures corresponding to such a bound state may be observed even in an inclusive measurement, if the decay width is narrow enough.

nucl-ex

Feasibility Study of Observing eta' Mesic Nuclei with (p,d) Reaction

A novel method is proposed to measure eta'(958) meson bound states in 11C nuclei by missing mass spectroscopy of the 12C(p,d) reaction near the eta' production threshold. It is shown that peak structures will be observed experimentally in an inclusive measurement in case that the in-medium eta' mass reduction is sufficiently large and that the decay width of eta' mesic states is narrow enough. Such a measurement will be feasible with the intense proton beam supplied by the SIS synchrotron at GSI combined with the good energy resolution of the fragment separator FRS.

nucl-ex

Application of Geiger-mode photo sensors in Cherenkov detectors

Silicon-based photosensors (SiPMs) working in the Geiger-mode represent an elegant solution for the readout of particle detectors working at low-light levels like Cherenkov detectors. Especially the insensitivity to magnetic fields makes this kind of sensors suitable for modern detector systems in subatomic physics which are usually employing magnets for momentum resolution. In our institute we are characterizing SiPMs of different manufacturers for selecting sensors and finding optimum operating conditions for given applications. Recently we designed and built a light concentrator prototype with 8x8 cells to increase the active photon detection area of an 8x8 SiPM (Hamamatsu MPPC S10931-100P) array. Monte Carlo studies, measurements of the collection efficiency, and tests with the MPPC were carried out. The status of these developments are presented.

physics.ins-det

Silicon photomultiplier timing performance study

Many characteristics of Silicon Photomultipliers can be tuned with temperature and operation voltage. We present preliminary results of a study of the effect of these two operation parameters on the time resolution of large active area Multi-Pixel Photon Counters (MPPCs) manufactured by Hamamatsu. Measurements at -10 C, 0 C, and 10 C at different bias voltages were performed. The time resolution is best at low temperature and high over-voltage. Most significant improvements can be achieved in cases with low number of fired pixels (<10 pixels). Between the worst and best case among the considered conditions a factor of 5 improvement was observed. In cases with large number of fired pixels (>40 pixels) the effect of temperature and operation voltage becomes smaller. The timing performance still improves with decreasing temperature (~ factor of 2) but it hardly depends on the operation voltage. The study shows, that especially in applications where only few photons are available for detection a careful optimization of temperature and operation voltage are advisable to obtain optimum timing results with the MPPC.

physics.ins-det

Development of a GEM-TPC prototype

The use of GEM foils for the amplification stage of a TPC instead of a con- ventional MWPC allows one to bypass the necessity of gating, as the backdrift is suppressed thanks to the asymmetric field configuration. This way, a novel continuously running TPC, which represents one option for the PANDA central tracker, can be realized. A medium sized prototype with a diameter of 300 mm and a length of 600 mm will be tested inside the FOPI spectrometer at GSI using a carbon or lithium beam at intermediate energies (E = 1-3AGeV). This detector test under realistic experimental conditions should allow us to verify the spatial resolution for single tracks and the reconstruction capability for displaced vertexes. A series of physics measurement implying pion beams is scheduled with the FOPI spectrometer together with the GEM-TPC as well.

physics.ins-det