SearcharxivSearch

arXiv subjects

Kenneth Livingston

Publications and source records attributed to Kenneth Livingston.

8 recordsLinked to original sources

Compact sub-10 ps Resolution Radio Frequency Photomultiplier Tube

Experimental measurements of the radial spreading of photoelectrons emitted from a multi-alkali photocathode in a MCP-based photomultiplier tube have shown that, for photon wavelengths of 455 nm, 515 nm and 625 nm, the maximum initial energies of the emitted photoelectrons are approximately 0.3 eV, 0.2 eV and 0.1 eV respectively. Combining these experimental results with simulations performed using the SIMION simulation package, a compact radio-frequency photoelectron multiplier tube with a temporal resolution better than 10 ps is proposed. The device would be suitable for applications in several fields, particularly in medical optical instruments employing time-correlated single-photon counting.

physics.ins-det

A Helical-Deflector-Based Radio-Frequency Spiral Scanning System for keV Energy Electrons

We present the design, modeling, and experimental validation of a radio-frequency based time-to-position conversion system for keV electrons incorporating a helical deflector operating in the 400-1000 MHz range. The device performs circular deflection of the electrons when driven by a single RF frequency and enables spiral scanning when two phase-locked RF voltages with slightly different frequencies are applied. The superposition of the two phase-locked RF voltages produces an amplitude-beating field whose slowly varying envelope modulates the deflection radius, transforming the circular scan into a controlled spiral on the detector plane. A detailed theoretical model describing the electron dynamics under two phase-locked RF voltages with different frequencies was derived, yielding analytical expressions for the transverse velocity and radius-vector components at the deflector exit. The experimental studies demonstrated good agreement with the model predictions. Spiral scanning will allow measurements with picosecond resolution in a temporal dynamic range 1-2 orders of magnitude larger than the period of the circular scanning.

physics.ins-det

Picosecond Precision Heavy-Ion Detector for {\Lambda} Hypernuclei Lifetime Studies

In this paper, we present the design and preliminary performance evaluation of a new heavy-ion detector for direct measurements of heavy {\Lambda} hypernuclei lifetime. The detector employs the previously developed 10 picosecond resolution Radio Frequency (RF) Timer, which converts the temporal information of incident particles into spatial coordinates of secondary or photoelectrons on a position-sensitive detector by means of circular RF scanning in the 500-1000 MHz range. Here, we report the detector design to achieve efficient suppression of accidental background and effective separation of prompt reaction products and delayed events from {\Lambda} hypernuclei decays, results of test studies carried out with RF synchronized laser as well as preliminary results obtained by using alpha particles. Dedicated Monte-Carlo simulations have been performed to estimate the detector's performance under realistic experimental conditions at RF-driven electron, photon, or proton beams. The results confirm the feasibility of the proposed design and provide a basis for upcoming experimental measurements, based on the delayed fission detection.

physics.ins-det

Advanced Radio Frequency Timing AppaRATus (ARARAT) Technique and Applications

The development of the advanced Radio Frequency Timer of electrons is described. It is based on a helical deflector, which performs circular or elliptical sweeps of keV electrons, by means of 500 MHz radio frequency field. By converting a time distribution of incident electrons to a hit position distribution on a circle or ellipse, this device achieves extremely precise timing. Streak Cameras, based on similar principles, routinely operate in the ps and sub-ps time domain, but have substantial slow readout system. Here, we report a device, where the position sensor, consisting of microchannel plates and a delay-line anode, produces ~ns duration pulses which can be processed by using regular fast electronics. A photon sensor based on this technique, the Radio Frequency Photo-Multiplier Tube (RFPMT), has demonstrated a timing resolution of ~10 ps and a time stability of ~0.5 ps, FWHM. This makes the apparatus highly suited for Time Correlated Single Photon Counting which is widely used in optical microscopy and tomography of biological samples. The first application in lifetime measurements of quantum states of graphene, under construction at the A. I. Alikhanyan National Science Laboratory (AANL), is outlined. This is followed by a description of potential RFPMT applications in time-correlated Diffuse Optical Tomography, time-correlated Stimulated Emission Depletion microscopy, hybrid FRET/STED nanoscopy and Time-of-Flight Positron Emission Tomography.

physics.ins-det

An RF Timer of Electrons and Photons with the Potential to reach Picosecond Precision

This paper describes a new radio frequency timer of keV energy electrons. It is based on a helical deflector, which performs circular or elliptical sweeps of keV electrons, by means of 500 MHz radio frequency field. By converting a time distribution of incident electrons to a hit position distribution on a circle or ellipse, this device achieves extremely precise timing. Streak Cameras, based on similar principles, routinely operate in the ps and sub-ps time domain, but have substantial dead time associated with the readout system. Here, we report a new type of RF timing technique, where the position sensor, consisting of microchannel plates and a delay-line anode, produces ~ns duration pulses with small dead time. Measurements made with sub-ps duration laser pulses, synchronized to the radio frequency power, produced a timing resolution of ~10 ps. This ultra-high precision technique has potential applications in a large variety of scientific devices, and in all cases, electrons are timed and detected simultaneously in the same device.

physics.ins-det

The HPS electromagnetic calorimeter

The Heavy Photon Search experiment (HPS) is searching for a new gauge boson, the so-called "heavy photon." Through its kinetic mixing with the Standard Model photon, this particle could decay into an electron-positron pair. It would then be detectable as a narrow peak in the invariant mass spectrum of such pairs, or, depending on its lifetime, by a decay downstream of the production target. The HPS experiment is installed in Hall-B of Jefferson Lab. This article presents the design and performance of one of the two detectors of the experiment, the electromagnetic calorimeter, during the runs performed in 2015-2016. The calorimeter's main purpose is to provide a fast trigger and reduce the copious background from electromagnetic processes through matching with a tracking detector. The detector is a homogeneous calorimeter, made of 442 lead-tungstate (PbWO4) scintillating crystals, each read out by an avalanche photodiode coupled to a custom trans-impedance amplifier.

physics.ins-det

Measurement of the generalized form factors near threshold via $γ^* p \to nπ^+$ at high $Q^2$

We report the first extraction of the pion-nucleon multipoles near the production threshold for the $nπ^+$ channel at relatively high momentum transfer ($Q^2$ up to 4.2 $\rm{GeV^2}$). The dominance of the s-wave transverse multipole ($E_{0+}$), expected in this region, allowed us to access the generalized form factor $G_1$ within the light-cone sum rule (LCSR) framework as well as the axial form factor $G_A$. The data analyzed in this work were collected by the nearly $4π$ CEBAF Large Acceptance Spectrometer (CLAS) using a 5.754 $\rm{GeV}$ electron beam on a proton target. The differential cross section and the $π-N$-multipole $E_{0+}/G_D$ were measured using two different methods, the LCSR and a direct multipole fit. The results from the two methods are found to be consistent and almost $Q^2$ independent.

nucl-ex