SearcharxivSearch

arXiv subjects

Kenneth W. Lin

Publications and source records attributed to Kenneth W. Lin.

3 recordsLinked to original sources

The La Silla Schmidt Southern Survey

We present the La Silla Schmidt Southern Survey (LS4), a new wide-field, time-domain survey to be conducted with the 1 m ESO Schmidt telescope. The 268 megapixel LS4 camera mosaics 32 2k$\times$4k fully depleted CCDs, providing a $\sim$20 deg$^2$ field of view with $1''$ pixel$^{-1}$ resolution. The LS4 camera will have excellent performance at longer wavelengths: in a standard 45 s exposure the expected 5$\sigma$ limiting magnitudes in $g$, $i$, $z$ are $\sim$21.5, $\sim$20.9, and $\sim$20.3 mag (AB), respectively. The telescope design requires a novel filter holder that fixes different bandpasses over each quadrant of the detector. Two quadrants will have $i$ band, while the other two will be $g$ and $z$ band and color information will be obtained by dithering targets across the different quadrants. The majority (90%) of the observing time will be used to conduct a public survey that monitors the extragalactic sky at both moderate (3 d) and high (1 d) cadence, as well as focused observations within the Galactic bulge and plane. Alerts from the public survey will be broadcast to the community via established alert brokers. LS4 will run concurrently with the Vera C. Rubin Observatory's Legacy Survey of Space and Time (LSST). The combination of LS4+LSST will enable detailed holistic monitoring of many nearby transients: high-cadence LS4 observations will resolve the initial rise and peak of the light curve while less-frequent but deeper observations by LSST will characterize the years before and after explosion. Here, we summarize the primary science objectives of LS4 including microlensing events in the Galaxy, extragalactic transients, the search for electromagnetic counterparts to multi-messenger events, and cosmology.

astro-ph.IM

Optimizing Charge-coupled Device Readout Enabled by the Floating-Gate Amplifier

Multiple-Amplifier Sensing (MAS) charge-coupled devices (CCDs) have recently been shown to be promising silicon detectors that meet noise sensitivity requirements for next generation Stage-5 spectroscopic surveys and potentially, future space-based imaging of extremely faint objects on missions such as the Habitable Worlds Observatory. Building upon the capability of the Skipper CCD to achieve deeply sub-electron noise floors, MAS CCDs utilize multiple floating-gate amplifiers along the serial register to increase the readout speed by a factor of the number of output nodes compared to a Skipper CCD. We introduce and experimentally demonstrate on a 16-channel prototype device new readout techniques that exploit the MAS CCD's floating-gate amplifiers to optimize the correlated double sampling (CDS) by resetting once per line instead of once per pixel. With this new mode, we find an optimal filter to subtract the noise from the signal during read out. We also take advantage of the MAS CCD's structure to tune the read time by independently changing integration times for the signal and reference level. Together with optimal weighted averaging of the 16 outputs, these approaches enable us to reach a sub-electron noise of 0.9 e$^-$ rms pix$^{-1}$ at 19 $\mu$s pix$^{-1}$ for a single charge measurement per pixel - simultaneously giving a 30% faster readout time and 10% lower read noise compared to performance previously evaluated without these techniques.

astro-ph.IM

Multi-Amplifier Sensing Charge-coupled Devices for Next Generation Spectroscopy

We present characterization results and performance of a prototype Multiple-Amplifier Sensing (MAS) silicon charge-coupled device (CCD) sensor with 16 channels potentially suitable for faint object astronomical spectroscopy and low-signal, photon-limited imaging. The MAS CCD is designed to reach sub-electron readout noise by repeatedly measuring charge through a line of amplifiers during the serial transfer shifts. Using synchronized readout electronics based on the DESI CCD controller, we report a read noise of 1.03 e$^-$ rms/pix at a speed of 26 $\mu$s/pix with a single-sample readout scheme where charge in a pixel is measured only once for each output stage. At these operating parameters, we find the amplifier-to-amplifier charge transfer efficiency (ACTE) to be $>0.9995$ at low counts for all amplifiers but one for which the ACTE is 0.997. This charge transfer efficiency falls above 50,000 electrons for the read-noise optimized voltage configuration we chose for the serial clocks and gates. The amplifier linearity across a broad dynamic range from $\sim$300 to 35,000 e$^-$ was also measured to be $\pm 2.5\%$. We describe key operating parameters to optimize on these characteristics and describe the specific applications for which the MAS CCD may be a suitable detector candidate.

astro-ph.IM