SearcharxivSearch

arXiv subjects

Kensuke Yamamoto

Publications and source records attributed to Kensuke Yamamoto.

8 recordsLinked to original sources

Letter Of Intent for a future $\mu^+ \to \mathrm{e}^+ \gamma$ experiment at the High Intensity Muon Beam facility at PSI

Searches for charged lepton flavor violation in the muon sector stand out among the most sensitive and clean probes for physics beyond the Standard Model. Currently, $\mu^+ \to \mathrm{e}^+ \gamma$ experiments provide the best constraints in this field for a wide range of models while, in the coming years, new experiments investigating the processes of $\mu^+ \to \mathrm{e}^+ \mathrm{e}^+ \mathrm{e}^-$ and $\mu \to \mathrm{e}$ conversion in the nuclear field are anticipated to reach comparable or higher sensitivities. The High-Intensity Muon Beam (HIMB) facility at PSI, which is expected to deliver muon beam intensities up to two orders of magnitude higher than the existing beam lines, offers a unique opportunity to significantly enhance the sensitivity of $\mu^+ \to \mathrm{e}^+ \gamma$ searches. The discovery potential could be substantially boosted and a sensitivity comparable to that of all the other projects could be reestablished, which is essential for discriminating among competing new-physics scenarios should an observation occur in any of the channels. In this document, we express our interest in developing a $\mu^+ \to \mathrm{e}^+ \gamma$ experimental program at HIMB, with the goal of improving, within the next decade, the sensitivity of the $\mu^+ \to \mathrm{e}^+ \gamma$ search by more than one order of magnitude relative to the expected final result of the current leading experiment, MEG II. This effort would ensure that PSI retains its leadership in this field.

hep-ex

Development of a high-rate capable DLC-RPC based on a current evacuation pattern

A Resistive Plate Chamber using Diamond-Like Carbon electrodes (DLC-RPC) has been developed as a background tagging detector in the MEG$~$II experiment. The DLC-RPC is planned to be installed in a high-intensity and low-momentum muon beam. This detector is required to have a detection efficiency above 90 % with four active gaps in the muon beam due to the limitation of the material budget. In such an environment, the high current flowing through the resistive electrodes causes a voltage drop, which reduces the performance of the DLC-RPC. This voltage drop can be suppressed by implementing a current evacuation pattern, though discharges are more likely to occur near the pattern. Therefore the pattern must be covered by a protection cover made of an insulator. In this study, electrode samples with a current evacuation pattern and different widths of protection cover (0.2 mm and 0.8 mm) have been produced, and their performance and stability were measured. The detection efficiency of a single-gap chamber for $\beta$-rays from a $^{90}$Sr source was measured to be up to approximately 60 % in both electrode samples. The target efficiency can be achieved even with a drop of 100 $-$ 150 V. On the other hand, after more than a dozen hours of operation, discharges suddenly occurred and the detector was prevented from further operation. These discharges created current paths on the spacing pillars. This serious problem must be investigated and solved in the future.

physics.ins-det

Photon energy reconstruction with the MEG II liquid xenon calorimeter

The MEG II experiment searches for a charged-lepton-flavour-violating $μ\to e γ$ with the target sensitivity of $6 \times 10^{-14}$. A liquid xenon calorimeter with VUV-sensitive photosensors measures photon position, timing, and energy. This paper concentrates on the precise photon energy reconstruction with the MEG II liquid xenon calorimeter. Since a muon beam rate is $3\text{-}5 \times 10^{7}~\text{s}^{-1}$, multi-photon elimination analysis is performed using waveform analysis techniques such as a template waveform fit. As a result, background events in the energy range of 48-58 MeV were reduced by 34 %. The calibration of the energy scale of the calorimeter with several calibration sources is also discussed to achieve a high resolution of 1.8 %.

physics.ins-det

Radiation Hardness Studies of RPC Based on Diamond-Like Carbon Electrodes for MEG II Experiment

A novel type of resistive plate chamber, based on diamond-like carbon (DLC) electrodes is under development for background identification in the MEG II experiment. The DLC-RPC is required to have a radiation hardness to mass irradiation since it is planned to be placed in a high-intensity and low-momentum muon beam. In this study, the aging test using a high-intensity X-ray beam was conducted to evaluate the radiation hardness of the DLC-RPC. The accumulated charge due to X-ray irradiation reached about 54 C/cm$^2$, which is approximately half of the one-year irradiation dose expected in the MEG II experiment. As a result, the degradation of the gas gain was observed due to fluorine deposition and insulators formed on the DLC electrodes. In addition, discharges via spacers were also observed repeatedly and interrupted the DLC-RPC operation.

physics.ins-det

Prototype study of $0.1\%\,X_0$ and $\mathrm{MHz/cm^2}$ tolerant Resistive Plate Chamber with Diamond-Like Carbon electrodes

A novel Resistive Plate Chamber (RPC) was designed with Diamond-Like Carbon (DLC) electrodes and performance studies were carried out for 384$\,\mathrm{μm}$ gap configuration with a $2\,\mathrm{cm}\times2\,\mathrm{cm}$ prototype. The use of thin films coated with DLC enables an ultra-low mass design of $< 0.1\%\,X_0$ with up to a four-layer configuration. At the same time, 42% MIP efficiency, and 180 ps timing resolution per layer were achieved in a measurement performed under a $1\,\mathrm{MHz/cm^2}$ non-MIP charged particle beam. In addition, we propose a further improved design for a $20\,\mathrm{cm}$-scale detector that can achieve 90% four-layer efficiency in an even higher $4\,\mathrm{MHz/cm^2}$ beam. In this paper, we describe the detector design, present the results of performance measurements, and characterize the rate capability of the DLC-based RPCs with a performance projection for an improved design.

physics.ins-det

Development of ultra-low mass and high-rate capable RPC based on Diamond-Like Carbon electrodes for MEG II experiment

A new type of resistive plate chamber with thin-film electrodes based on diamond-like carbon is under development for background identification in the MEG II experiment. Installed in a low-momentum and high-intensity muon beam, the detector is required to have extremely low mass and a high rate capability. A single-layer prototype detector with 2 cm $\times$ 2 cm size was constructed and evaluated to have a high rate capability of 1 MHz/cm$^2$ low-momentum muons. For a higher rate capability and scalability of the detector size, the electrodes to supply high voltage were segmented at a 1 cm pitch by implementing a conductive pattern on diamond-like carbon. Using the new electrodes, a four-layer prototype detector was constructed and evaluated to have a 46% detection efficiency with only a single layer active at a rate of $\cal O$(10 kHz). The result with the new electrodes is promising to achieve the required detection efficiency of 90% at a rate of 4 MHz/cm$^2$ with all the layers active.

physics.ins-det

Development of high-rate capable and ultra-low mass Resistive Plate Chamber with Diamond-Like Carbon

A new type of resistive plate chamber (RPC) is under development using thin-film resistive electrodes based on diamond-like carbon (DLC). Planned to be put on the path of high-intensity low-momentum muon beam of the MEG II experiment, this detector is required to be high-rate capable and ultra-low mass. Using a prototype detector with 2 cm $\times$ 2 cm size and 0.1 % $X_0$ material budget, performance studies were conducted for MIP detection efficiency, timing resolution and high rate capability in low-momentum muon beam. In this paper, the measured performance is presented including the result with low-momentum muon beam at rate up to 1 $\mathrm{MHz/cm^2}$. Based on the result, the expected performance of the full-scale detector in the MEG~II experiment is also discussed.

physics.ins-det

The Search for $μ^+\to e^+ γ$ with 10$^{-14}$ Sensitivity: the Upgrade of the MEG Experiment

The MEG experiment took data at the Paul Scherrer Institute in the years 2009--2013 to test the violation of the lepton flavour conservation law, which originates from an accidental symmetry that the Standard Model of elementary particle physics has, and published the most stringent limit on the charged lepton flavour violating decay $μ^+ \rightarrow {\rm e}^+ γ$: BR($μ^+ \rightarrow {\rm e}^+ γ$) $<4.2 \times 10^{-13}$ at 90% confidence level. The MEG detector has been upgraded in order to reach a sensitivity of $6\times10^{-14}$. The basic principle of MEG II is to achieve the highest possible sensitivity using the full muon beam intensity at the Paul Scherrer Institute ($7\times10^{7}$ muons/s) with an upgraded detector. The main improvements are better rate capability of all sub-detectors and improved resolutions while keeping the same detector concept. In this paper, we present the current status of the preparation, integration and commissioning of the MEG II detector in the recent engineering runs.

hep-ex