SearcharxivSearch

arXiv subjects

Kentaro Miuchi

Publications and source records attributed to Kentaro Miuchi.

At least 19 recordsLinked to original sources

Measurement of ionization yield of low energy ions in low pressure $\mathrm{CF}_{4}$ gas for dark matter searches

Direction-sensitive direct dark matter search experiments have been conducted using gaseous detectors. In spite of the long history of the study on the energy deposition of charged particles in materials, a full agreement between the measured results and theoretical predictions, especially in a low energy scale, are yet to be achieved. It is thus important to measure the ionization yields of recoil nuclei for the experiments with gaseous detectors using an ionization charge readout scheme. This study measured the ionization yield using a low-energy ion beam facility at Kanagawa University. The ionization yields for fluorine ions with an energy range of 5 $\sim$ 50 keV were measured using a dedicated proportional wire chamber filled with $\mathrm{CF}_{4}$ gas at 0.06 atm. The low-energy ion injection scheme into a gaseous detector was established and the ionization yield for fluorine ions was obtained to be 0.45 at 30 keV with a moderate dependence on the ion energy.

physics.ins-det

Development of a low-background micro pixel chamber for directional dark matter searches

Direct detection of weakly interacting massive particles (WIMPs) can provide strong evidence of their existence and the directional method would have an advantage over other methods to detect the clear signal of WIMPs. Time projection chambers with micro-patterned gaseous detectors (MPGDs) are one of the common devices used in directional WIMP searches. A micro pixel chamber ($\mu$-PIC), one of the various types of MPGDs, with specially selected low background materials (LBG$\mu$-PIC) was developed and its performance was studied. The radon emission of the LBG$\mu$-PIC was less than 1/60 of that of the $\mu$-PIC currently in use. Although a non-negligible gain non-homogeneity was seen for the LBG$\mu$-PIC, it can be used for the directional WIMP search with the correction of the non-homogeneity.

physics.ins-det

High-energy extension of the gamma-ray band observable with an electron-tracking Compton camera

Although the MeV gamma-ray band is a promising energy-band window in astrophysics, the current situation of MeV gamma-ray astronomy significantly lags behind those of the other energy bands in angular resolution and sensitivity. An electron-tracking Compton camera (ETCC), a next-generation MeV detector, is expected to revolutionize the situation. An ETCC tracks each Compton-recoil electron with a gaseous electron tracker and determines the incoming direction of each gamma-ray photon; thus, it has a strong background rejection power and yields a better angular resolution than classical Compton cameras. Here, we study ETCC events in which the Compton-recoil electrons do not deposit all energies to the electron tracker but escape and hit the surrounding pixel scintillator array (PSA). We developed an analysis method for this untapped class of events and applied it to laboratory and simulation data. We found that the energy spectrum obtained from the simulation agreed with that of the actual data within a factor of 1.2. We then evaluated the detector performance using the simulation data. The angular resolution for the new-class events was found to be twice as good as in the previous study at the energy range 1.0--2.0~MeV, where both analyses overlap. We also found that the total effective area is dominated by the contribution of the double-hit events above an energy of 1.5~MeV. Notably, applying this new method extends the sensitive energy range with the ETCC from 0.2--2.1 MeV in the previous studies to up to 3.5~MeV. Adjusting the PSA dynamic range should improve the sensitivity in even higher energy gamma-rays. The development of this new analysis method would pave the way for future observations by ETCC to fill the MeV-band sensitivity gap in astronomy.

astro-ph.HE

High-pressure xenon gas time projection chamber with scalable design and its performance at around the Q value of $^{136}$Xe double-beta decay

We have been developing a high-pressure xenon gas time projection chamber (TPC) to search for neutrinoless double beta ($0\nu\beta\beta$) decay of $^{136}$Xe. The unique feature of this TPC is in the detection part of ionization electrons, called ELCC. ELCC is composed of multiple units, and one unit covers 48.5 $\mathrm{cm}^2$. A 180 L size prototype detector with 12 units, 672 channels, of ELCC was constructed and operated with 7.6 bar natural xenon gas to evaluate the performance of the detector at around the Q value of $^{136}$Xe $0\nu\beta\beta$. The obtained FWHM energy resolution is (0.73 $\pm$ 0.11) % at 1836 keV. This corresponds to (0.60 $\pm$ 0.03) % to (0.70 $\pm$ 0.21) % of energy resolution at the Q value of $^{136}Xe$ $0\nu\beta\beta$. This result shows the scalability of the AXEL detector with ELCC while maintaining high energy resolution. Factors determining the energy resolution were quantitatively evaluated and the result indicates further improvement is feasible. Reconstructed track images show distinctive structures at the endpoint of electron tracks, which will be an important feature to distinguish $0\nu\beta\beta$ signals from gamma-ray backgrounds.

physics.ins-det

Challenges for the directional dark matter direct detection

Directional methods have been considered to provide a solid proof for the direct detection of the dark matter. Gaseous time-projection-chambers (TPCs) are the most mature devices for directional dark matter searches although there still exist several challenges to overcome. This paper reviews the history, current challenges and future prospects of the gaseous TPCs for directional dark matter searches.

hep-ex

First reconstruction of absolute three-dimensional position of nuclear recoils using a negative ion $\mu$-TPC for dark matter search experiments

Studies of micro time projection chambers using negative ion gas (NI$\mu$TPC) are conducted especially for direction-sensitive dark matter searches. A NI$\mu$TPC enables to measure the absolute position in the drift direction for self-triggering TPCs. This study provides a development of a NI$\mu$TPC using a micro pixel chamber ($\mu$-PIC) with dedicated readout electronics, and an evaluation of the capability of three-dimensional absolute position reconstruction of nuclear recoil using a neutron source. The absolute track position was reconstructed throughout the drift volume with an efficiency of 70$\pm$5%. This work marks an important step for the NI$\mu$TPCs towards the practical use for directional dark matter searches.

physics.ins-det

Direction-sensitive dark matter search with three-dimensional vector-type tracking in NEWAGE

NEWAGE is a direction-sensitive dark matter search experiment with a three-dimensional tracking detector based on a gaseous micro time projection chamber. A direction-sensitive dark matter search was carried out at Kamioka Observatory with a total live time of 318.0 days resulting in an exposure of 3.18 kg$\cdot$days. A new gamma-ray rejection and a head-tail determination analysis were implemented for this work. No significant non-isotropic signal from the directional analysis was found and a 90% confidence level upper limit on spin-dependent WIMP-proton cross section of 25.7 pb for WIMP mass of 150 GeV/c2 was derived. This upper limit is the most stringent in the direction-sensitive dark matter searches.

hep-ex

Measurement of radon emanation and impurity adsorption from argon gas using ultralow radioactive zeolite

The amount of radioactive impurities contaminated in the detector gases is required to be kept at a very low level for rare event particle physics such as dark matter and neutrino observation experiments. Zeolite is a well-known class of materials and is one of the possible candidates for removing impurities from these gases. At the same time, the amount of radioactive impurities released from the adsorbent material needs to be sufficiently small. In this paper, a development of a new ultralow radioactive zeolite as a product of the selection of ultralow radioactive materials is reported. Results on the radon emanation and impurity adsorption from argon gas measurements are also described.

physics.ins-det

ISAI: Investigating Solar Axion by Iron-57

The existence of the axion is a unique solution for the strong CP problem, and the axion is one of the most promising candidates of the dark matter. Investigating Solar Axion by Iron-57 (ISAI) is being prepared as a complemented table-top experiment to confirm the solar axion scenario. Probing an X-ray emission from the nuclear transitions associated with the axion-nucleon coupling is a leading approach. ISAI searches for the monochromatic 14.4 keV X-ray from the first excited state of 57Fe using a state-of-the-art pixelized silicon detector, dubbed XRPIX, under an extremely low-background environment. We highlight scientific objectives, experimental design and the latest status of ISAI.

astro-ph.IM

Directional direct detection of light dark matter up-scattered by cosmic rays from direction of the Galactic center

Dark matter with MeV scale mass is difficult to detect with standard direct search detectors. However, they can be searched for by considering the up-scattering of kinetic energies by cosmic rays. Because the dark matter density is higher in the central region of the Galaxy, the up-scattered dark matter will arrive at Earth from the direction of the Galactic center. Once the dark matter is detected, we can expect to recognize this feature by directional direct detection experiments. In this study, we simulate the nuclear recoils of the up-scattered dark matter and quantitatively reveal that a large amount of this type of dark matter is arriving from the direction of the Galactic center. Also, we have shown that the characteristic signatures of the up-scattered dark matter can be verified with more than 5$\sigma$ confidence levels for the assumed target atoms and future upgrades to directional detectors.

astro-ph.CO

Scintillation light increase of carbontetrafluoride gas at low temperature

Scintillation detector is widely used for the particle detection in the field of particle physics. Particle detectors containing fluorine-19 ($^{19}\mathrm{F}$) are known to have advantages for Weakly Interacting Massive Particles (WIMPs) dark matter search, especially for spin-dependent interactions with WIMPs due to its spin structure. In this study, the scintillation properties of carbontetrafluoride ($\mathrm{CF_{4}}$) gas at low temperature was evaluated because its temperature dependence of light yield has not been measured. We evaluated the light yield by cooling the gas from room temperature (300K) to 263K. As a result, the light yield of $\mathrm{CF_{4}}$ was found to increase by $(41.0\pm4.0_{\rm stat.}\pm6.6_{\rm syst.})\%$ and the energy resolution was also found to improve at low temperature.

physics.ins-det

First observation of MeV gamma-ray universe with bijective imaging spectroscopy using the Electron-Tracking Compton Telescope aboard SMILE-2+

MeV gamma-rays provide a unique window for the direct measurement of line emissions from radioisotopes, but observations have made little significant progress after COMPTEL/{\it CGRO}. To observe celestial objects in this band, we are developing an electron-tracking Compton camera (ETCC), which realizes both bijective imaging spectroscopy and efficient background reduction gleaned from the recoil electron track information. The energy spectrum of the observation target can then be obtained by a simple ON-OFF method using a correctly defined point spread function on the celestial sphere. The performance of celestial object observations was validated on the second balloon SMILE-2+ installed with an ETCC having a gaseous electron tracker with a volume of 30$\times$30$\times$30 cm$^3$. Gamma-rays from the Crab nebula were detected with a significance of 4.0$\sigma$ in the energy range 0.15--2.1 MeV with a live time of 5.1 h, as expected before launching. Additionally, the light curve clarified an enhancement of gamma-ray events generated in the Galactic center region, indicating that a significant proportion of the final remaining events are cosmic gamma rays. Independently, the observed intensity and time variation were consistent with the pre-launch estimates except in the Galactic center region. The estimates were based on the total background of extragalactic diffuse, atmospheric, and instrumental gamma-rays after accounting for the variations in the atmospheric depth and rigidity during the level flight. The Crab results and light curve strongly support our understanding of both the detection sensitivity and the background in real observations. This work promises significant advances in MeV gamma-ray astronomy.

astro-ph.HE

Axion search with quantum nondemolition detection of magnons

The axion provides a solution for the strong CP problem and is one of the leading candidates for dark matter. This paper proposes an axion detection scheme based on quantum nondemolition detection of magnon, i.e., quanta of collective spin excitations in solid, which is expected to be excited by the axion-electron interaction predicted by the Dine-Fischer-Srednicki-Zhitnitsky (DFSZ) model. The prototype detector is composed of a ferrimagnetic sphere as an electronic spin target and a superconducting qubit. Both of these are embedded inside a microwave cavity, which leads to a coherent effective interaction between the uniform magnetostatic mode in the ferrimagnetic crystal and the qubit. An upper limit for the coupling constant between an axion and an electron is obtained as $g_{aee}<2.6\times10^{-6}$ at the 95% confidence level for the axion mass of $33.117$$\mu$eV $<m_{a}<33.130$$\mu$eV.

hep-ex

Direction-sensitive dark matter search with a low-background gaseous detector NEWAGE-0.3b''

NEWAGE is a direction-sensitive dark matter search using a low-pressure gaseous time projection chamber. A low alpha-ray emission rate micro pixel chamber had been developed in order to reduce background for dark matter search. We conducted the dark matter search at the Kamioka Observatory in 2018. The total live time was 107.6 days corresponding to an exposure of 1.1 kg${\cdot}$days. Two events remained in the energy region of 50-60 keV which was consistent with 2.5 events of the expected background. A directional analysis was carried out and no significant forward-backward asymmetry derived from the WIMP-nucleus elastic scatterings was found. Thus a 90% confidence level upper limit on Spin-Dependent WIMP-proton cross section of 50 pb for a WIMP mass of 100 GeV/c2 was derived. This limit is the most stringent yet obtained from direction-sensitive dark matter search experiments.

hep-ex

Detection capability of Migdal effect for argon and xenon nuclei with position sensitive gaseous detectors

Migdal effect is attracting interests because of the potential to enhance the sensitivities of direct dark matter searches to the low mass region. In spite of its great importance, the Migdal effect has not been experimentally observed yet. A realistic experimental approach towards the first observation of the Migdal effect in the neutron scattering was studied with Monte Carlo simulations. In this study, potential background rate was studied together with the event rate of the Migdal effect by a neutron source. It was found that a table-top sized $\sim (30\rm cm )^3$ position-sensitive gaseous detector filled with argon or xenon target gas can detect characteristic signatures of the Migdal effect with sufficient rates (O($10^2\sim10^3$) events/day). A simulation result of a simple experimental set-up showed two significant background sources, namely the intrinsic neutrons and the neutron induced gamma-rays. These background rates were found to be much higher than those of the Migdal effect in the neutron scattering. As a consequence of this study, it is concluded that the experimental observation of the Migdal effect in the neutron scattering can be realized with a good understanding and reduction of the background.

physics.ins-det

First limits from a 3d-vector directional dark matter search with the NEWAGE-0.3b' detector

The first directional dark matter search with three-dimensional tracking with head-tail sensitivity (3d-vector tracking analysis) was performed with a gaseous three-dimensional tarcking detector, or the NEWAGE-0.3b' detector. The search was carried out from July 2013 to August 2017 (Run14 to Run18) at the Kamioka underground laboratory. The total livetime is 434.85 days corresponding to an exposure of 4.51 kg$\cdot$days. A 90 % confidence level upper limit on spin-dependent WIMP-proton cross section of $4.3 \times10^{2}$ pb for WIMPs with the mass of 150 GeV/$c^2$ is obtained.

hep-ex

Development of a low-$\alpha$-emitting $\mu$-PIC as a readout device for direction-sensitive dark matter detectors

Direction sensitivity could provide robust evidence for the direct detection of weakly interacting massive particles constituting dark matter. However, the sensitivity of this method remains low due to the radioactive backgrounds. The purpose of this study is to develop a low-background detector as a two-dimensional imaging device for a gaseous time projection chamber. In direction-sensitive dark matter experiments~(e.g. NEWAGE), $\alpha$-rays emitted from the detector components often create substantial radioactive backgrounds. Based on the study of the background of NEWAGE, a new detector "low-$\alpha$ $\mu$-PIC" is developed. The produced $\mu$-PIC performs well as a gas detector and the $\alpha$-ray emission rate from the $\mu$-PIC reduced by a factor of 100.

physics.ins-det

Measurement of ambient neutrons in an underground laboratory at Kamioka Observatory and future plan

Ambient neutrons are one of the most serious backgrounds for underground experiments in search of rare events. The ambient neutron flux in an underground laboratory of Kamioka Observatory was measured using a $\mathrm{^3He}$ proportional counter with various moderator setups. Since the detector response largely depends on the spectral shape, the energy spectra of the neutrons transported from the rock to the laboratory were estimated by Monte-Carlo simulations. The ratio of the thermal neutron flux to the total neutron flux was found to depend on the thermalizing efficiency of the rock. Thus, the ratio of the count rate without a moderator to that with a moderator was used to determine this parameter. Consequently, the most-likely neutron spectrum predicted by the simulations for the parameters determined by the experimental results was obtained. The result suggests an interesting spectral shape, which has not been indicated in previous studies. The total ambient neutron flux is $(23.5 \pm 0.7 \ \mathrm{_{stat.}} ^{+1.9}_{-2.1} \ \mathrm{_{sys.}}) \times 10^{-6}$ cm$^{-2}$ s$^{-1}$. In this paper, we explain our method of the result and discuss our future plan.

physics.ins-det