Influence of non-uniformity in sapphire substrates for a gravitational wave telescope

Construction of a large-scale cryogenic gravitational-wave telescope KAGRA has been completed and the four sapphire test masses have been installed in cryostat vacuum chambers. It recently turned out that a sapphire substrate used for one of the input test masses shows a characteristic strcuture in its transmission map due to non-uniformity of the crystal. We performed an interferometer simulation to see the influence of the non-uniformity using measured transmission/reflection maps.

astro-ph.IM↗

Mirror actuation design for the interferometer control of the KAGRA gravitational wave telescope

KAGRA is a 3-km cryogenic interferometric gravitational wave telescope located at an underground site in Japan. In order to achieve its target sensitivity, the relative positions of the mirrors of the interferometer must be finely adjusted with attached actuators. We have developed a model to simulate the length control loops of the KAGRA interferometer with realistic suspension responses and various noises for mirror actuation. Using our model, we have designed the actuation parameters to have sufficient force range to acquire lock as well as to control all the length degrees of freedom without introducing excess noise.

physics.ins-det↗

Prospects for improving the sensitivity of KAGRA gravitational wave detector

KAGRA is a new gravitational wave detector which aims to begin joint observation with Advanced LIGO and Advanced Virgo from late 2019. Here, we present KAGRA's possible upgrade plans to improve the sensitivity in the decade ahead. Unlike other state-of-the-art detectors, KAGRA requires different investigations for the upgrade since it is the only detector which employs cryogenic cooling of the test mass mirrors. In this paper, investigations on the upgrade plans which can be realized by changing the input laser power, increasing the mirror mass, and injecting frequency dependent squeezed vacuum are presented. We show how each upgrade affects to the detector frequency bands and also discuss impacts on gravitational-wave science. We then propose an effective progression of upgrades based on technical feasibility and scientific scenarios.

gr-qc↗

Particle swarm optimization of the sensitivity of a cryogenic gravitational wave detector

Cryogenic cooling of the test masses of interferometric gravitational wave detectors is a promising way to reduce thermal noise. However, cryogenic cooling limits the incident power to the test masses, which limits the freedom of shaping the quantum noise. Cryogenic cooling also requires short and thick suspension fibers to extract heat, which could result in the worsening of thermal noise. Therefore, careful tuning of multiple parameters is necessary in designing the sensitivity of cryogenic gravitational wave detectors. Here, we propose the use of particle swarm optimization to optimize the parameters of these detectors. We apply it for designing the sensitivity of the KAGRA detector, and show that binary neutron star inspiral range can be improved by 10%, just by retuning seven parameters of existing components. We also show that the sky localization of GW170817-like binaries can be further improved by a factor of 1.6 averaged across the sky. Our results show that particle swarm optimization is useful for designing future gravitational wave detectors with higher dimensionality in the parameter space.

gr-qc↗

Measurement of optical losses in a high-finesse 300 m filter cavity for broadband quantum noise reduction in gravitational-wave detectors

Earth-based gravitational-wave detectors will be limited by quantum noise in a large part of their spectrum. The most promising technique to achieve a broadband reduction of such noise is the injection of a frequency dependent squeezed vacuum state from the output port of the detector, whit the squeeze angle rotated by the reflection off a Fabry-Perot filter cavity. One of the most important parameters limiting the squeezing performance is represented by the optical losses of the filter cavity. We report here the operation of a 300 m filter cavity prototype installed at the National Astronomical Observatory of Japan (NAOJ). The cavity is designed to obtain a rotation of the squeeze angle below 100 Hz. After achieving the resonance of the cavity with a multi-wavelength technique, the round trip losses have been measured to be between 50 ppm and 90 ppm. This result demonstrates that with realistic assumption on the input squeeze factor and on the other optical losses, a quantum noise reduction of at least 4 dB in the frequency region dominated by radiation pressure can be achieved.

astro-ph.IM↗

A Direct Approach for the Fluctuation-Dissipation Theorem under Non-Equilibrium Steady-State Conditions

The test mass suspensions of cryogenic gravitational-wave detectors such as the KAGRA project are tasked with extracting the heat deposited on the optics. Thus these suspensions have a non-uniform temperature, requiring the calculation of thermal noise in non-equilibrium conditions. While it is not possible to describe the whole suspension system with one temperature, the local temperature anywhere in the system is still well defined. We therefore generalize the application of the fluctuation-dissipation theorem to mechanical systems, pioneered by Saulson and Levin, to non-equilibrium conditions in which a temperature can only be defined locally. The result is intuitive in the sense that the temperature-averaging relevant for the thermal noise in the observed degree of freedom is given by averaging the temperature field, weighted by the dissipation density associated with that particular degree of freedom. After proving this theorem we apply the result to examples of increasing complexity: a simple spring, the bending of a pendulum suspension fiber, as well as a model of the KAGRA cryogenic suspension. We conclude by outlining the application to non-equilibrium thermo-elastic noise.

gr-qc↗

Measurement and subtraction of Schumann resonances at gravitational-wave interferometers

Correlated magnetic noise from Schumann resonances threatens to contaminate the observation of a stochastic gravitational-wave background in interferometric detectors. In previous work, we reported on the first effort to eliminate global correlated noise from the Schumann resonances using Wiener filtering, demonstrating as much as a factor of two reduction in the coherence between magnetometers on different continents. In this work, we present results from dedicated magnetometer measurements at the Virgo and KAGRA sites, which are the first results for subtraction using data from gravitational-wave detector sites. We compare these measurements to a growing network of permanent magnetometer stations, including at the LIGO sites. We show how dedicated measurements can reduce coherence to a level consistent with uncorrelated noise. We also show the effect of mutual magnetometer attraction, arguing that magnetometers should be placed at least one meter from one another.

gr-qc↗

Design study of the KAGRA output mode-cleaner

Most second-generation gravitational-wave detectors employ an optical resonator called an output mode-cleaner (OMC), which filters out junk light from the signal and the reference light, before it reaches the detection photodiode located at the asymmetric port of the large-scale interferometer. The optical parameters of the OMC should be carefully chosen to satisfy the requirements to filter out unwanted light whilst transmitting the gravitational wave signal and reference light. The Japanese gravitational-wave detector KAGRA plans to use a very small amount of reference light to minimize the influence of quantum noise for gravitational waves from binary neutron stars, and hence the requirements to the OMC are more challenging than for other advanced detectors. In this paper, we present the result of numerical simulations, which verify that the OMC requirements are satisfied with the current design. We use the simulation program FINESSE and realistic mirror phase maps that have the same surface quality as the KAGRA test masses.

physics.optics↗

Method to reduce excess noise of a detuned cavity for application in KAGRA

Ground-based gravitational-wave detectors are based on high precision laser interferometry. One promising technique to improve the detector's sensitivity is the detuning of an optical cavity, which enhances the signal at around certain frequencies for target astronomical sources. The detuning, however, involves technical noise due to an asymmetry of the control sidebands, which includes photo-detector noise and oscillator-phase noise. Here, we introduce a solution to reduce the two kinds of excess noise using an amplitude-modulation sideband that compensates the asymmetry. The solution is planned to be implemented in the Japanese second-generation gravitational-wave detector KAGRA.

gr-qc↗

Interferometer design of the KAGRA gravitational wave detector

KAGRA is a cryogenic interferometric gravitational wave detector being constructed at the underground site of Kamioka mine in Gifu prefecture, Japan. We performed an optimization of the interferomter design, to achieve the best sensitivity and a stable operation, with boundary conditions of classical noises and under various practical constraints, such as the size of the tunnel or the mirror cooling capacity. Length and alignment sensing schemes for the robust control of the interferometer are developed. In this paper, we describe the detailed design of the KAGRA interferometer as well as the reasoning behind design choices.

gr-qc↗

Detector configuration of KAGRA - the Japanese cryogenic gravitational-wave detector

Construction of the Japanese second-generation gravitational-wave detector KAGRA has been started. In the next 6 \sim 7 years, we will be able to observe the space-time ripple from faraway galaxies. KAGRA is equipped with the latest advanced technologies. The entire 3-km long detector is located in the underground to be isolated from the seismic motion, the core optics are cooled down to 20 K to reduce thermal fluctuations, and quantum non-demolition techniques are used to decrease quantum noise. In this paper, we introduce the detector configuration of KAGRA; its design, strategy, and downselection of parameters.

gr-qc↗

Length sensing and control strategies for the LCGT interferometer

The optical readout scheme for the length degrees of freedom of the LCGT interferometer is proposed. The control scheme is compatible both with the broadband and detuned operations of the interferometer. Interferometer simulations using a simulation software Optickle show that the sensing noise couplings caused by the feedback control can be reduced below the target sensitivity of LCGT with the use of feed forward. In order to improve the duty cycle of the detector, a robust lock acquisition scheme using auxiliary lasers will be used.

gr-qc↗

The 10m AEI prototype facility A brief overview

The AEI 10 m prototype interferometer facility is currently being constructed at the Albert Einstein Institute in Hannover, Germany. It aims to perform experiments for future gravitational wave detectors using advanced techniques. Seismically isolated benches are planned to be interferometrically interconnected and stabilized, forming a low-noise testbed inside a 100 m^3 ultra-high vacuum system. A well-stabilized high power laser will perform differential position readout of 100 g test masses in a 10 m suspended arm-cavity enhanced Michelson interferometer at the crossover of measurement (shot) noise and backaction (quantum radiation pressure) noise, the so-called Standard Quantum Limit (SQL). Such a sensitivity enables experiments in the highly topical field of macroscopic quantum mechanics. In this article we introduce the experimental facility and describe the methods employed, technical details of subsystems will be covered in future papers.

physics.optics↗

Reducing Thermal Noise in Future Gravitational Wave Detectors by employing Khalili Etalons

Reduction of thermal noise in dielectric mirror coatings is a key issue for the sensitivity improvement in second and third generation interferometric gravitational wave detectors. Replacing an end mirror of the interferometer by an anti-resonant cavity (a so-called Khalili cavity) has been proposed to realize the reduction of the overall thermal noise level. In this article we show that the use of a Khalili etalon, which requires less hardware than a Khalili cavity, yields still a significant reduction of thermal noise. We identify the optimum distribution of coating layers on the front and rear surfaces of the etalon and compare the total noise budget with a conventional mirror. In addition we briefly discuss advantages and disadvantages of the Khalili etalon compared with the Khalili cavity in terms of technical aspects, such as interferometric length control and thermal lensing.

gr-qc↗

Reduction of coating thermal noise by using an etalon

Reduction of coating thermal noise is a key issue in precise measurements with an optical interferometer. A good example of such a measurement device is a gravitational-wave detector, where each mirror is coated by a few tens of quarter-wavelength dielectric layers to achieve high reflectivity while the thermal-noise level increases with the number of layers. One way to realize the reduction of coating thermal noise, recently proposed by Khalili, is the mechanical separation of the first few layers from the rest so that a major part of the fluctuations contributes only little to the phase shift of the reflected light. Using an etalon, a Fabry-Perot optical resonator of a monolithic cavity, with a few coating layers on the front and significantly more on the back surface is a way to realize such a system without too much complexity, and in this paper we perform a thermal-noise analysis of an etalon using the Fluctuation-dissipation theorem with probes on both sides of a finite-size cylindrical mirror.

gr-qc↗

Probing macroscopic quantum states with a sub-Heisenberg accuracy

Significant achievements in the reduction of classical-noise floor will allow macroscopic systems to prepare nearly Heisenberg-Limited quantum states through a continuous measurement, i.e. conditioning. In order to probe the conditional quantum state and confirm quantum dynamics, we propose use of an optimal time-domain variational measurement, in which the homodyne detection phase varies in time. This protocol allows us to characterize the macroscopic quantum state below the Heisenberg Uncertainty -- i.e. Quantum Tomography -- and the only limitation comes from readout loss which enters in a similar manner as the frequency-domain variational scheme proposed by Kimble et al.. In the case of no readout loss, it is identical to the back-action-evading scheme invented by Vyatchanin et al. for detecting gravitational-wave (GW) signal with known arrival time. As a special example and to motivate Macroscopic Quantum Mechanics (MQM) experiments with future GW detectors, we mostly focus on the free-mass limit -- the characteristic measurement frequency is much higher than the oscillator frequency -- and further assume the classical noises are Markovian, which captures the main feature of a broadband GW detector. Besides, we consider verifications of Einstein-Podolsky-Rosen (EPR) type entanglements between macroscopic test masses in GW detectors, which enables to test one particular version of Gravity Decoherence conjectured by Diosi and Penrose.

quant-ph↗

Quantum noise of a Michelson-Sagnac interferometer with translucent mechanical oscillator

Quantum fluctuations in the radiation pressure of light can excite stochastic motions of mechanical oscillators thereby realizing a linear quantum opto-mechanical coupling. When performing a precise measurement of the position of an oscillator, this coupling results in quantum radiation pressure noise. Up to now this effect has not been observed yet. Generally speaking, the strength of radiation pressure noise increases when the effective mass of the oscillator is decreased or when the power of the reflected light is increased. Recently, extremely light SiN membranes with high mechanical Q-values at room temperature have attracted attention as low thermal noise mechanical oscillators. However, the power reflectance of these membranes is much lower than unity which makes the use of advanced interferometer recycling techniques to amplify the radiation pressure noise in a standard Michelson interferometer inefficient. Here, we propose and theoretically analyze a Michelson-Sagnac interferometer that includes the membrane as a common end mirror for the Michelson interferometer part. In this new topology, both, power- and signal-recycling can be used even if the reflectance of the membrane is much lower than unity. In particular, signal-recycling is a useful tool because it does not involve a power increase at the membrane. We derive the formulas for the quantum radiation pressure noise and the shot-noise of an oscillator position measurement and compare them with theoretical models of the thermal noise of a SiN membrane with a fundamental resonant frequency of 75 kHz and an effective mass of 125 ng. We find that quantum radiation pressure noise should be observable with a power of 1 W at the central beam splitter of the interferometer and a membrane temperature of 1 K.

quant-ph↗

Coating thermal noise of a finite-size cylindrical mirror

Thermal noise of a mirror is one of the limiting noise sources in the high precision measurement such as gravitational-wave detection, and the modeling of thermal noise has been developed and refined over a decade. In this paper, we present a derivation of coating thermal noise of a finite-size cylindrical mirror based on the fluctuation-dissipation theorem. The result agrees to a previous result with an infinite-size mirror in the limit of large thickness, and also agrees to an independent result based on the mode expansion with a thin-mirror approximation. Our study will play an important role not only to accurately estimate the thermal-noise level of gravitational-wave detectors but also to help analyzing thermal noise in quantum-measurement experiments with lighter mirrors.

gr-qc↗