ROIX-Comp: Optimizing X-ray Computed Tomography Imaging Strategy for Data Reduction and Reconstruction

In high-performance computing (HPC) environments, particularly in synchrotron radiation facilities, vast amounts of X-ray images are generated. Processing large-scale X-ray Computed Tomography (X-CT) datasets presents significant computational and storage challenges due to their high dimensionality and data volume. Traditional approaches often require extensive storage capacity and high transmission bandwidth, limiting real-time processing capabilities and workflow efficiency. To address these constraints, we introduce a region-of-interest (ROI)-driven extraction framework (ROIX-Comp) that intelligently compresses X-CT data by identifying and retaining only essential features. Our work reduces data volume while preserving critical information for downstream processing tasks. At pre-processing stage, we utilize error-bounded quantization to reduce the amount of data to be processed and therefore improve computational efficiencies. At the compression stage, our methodology combines object extraction with multiple state-of-the-art lossless and lossy compressors, resulting in significantly improved compression ratios. We evaluated this framework against seven X-CT datasets and observed a relative compression ratio improvement of 12.34x compared to the standard compression.

eess.IV

In vivo imaging of central nervous system fluid spaces using synchrotron radiation-based micro computed tomography

Current approaches to in vivo imaging of the mouse central nervous system (CNS) do not offer a combination of micrometer resolution and a whole-brain field of view. To address this limitation, we introduce an approach based on synchrotron radiation-based hard X-ray micro computed tomography (SR$\mu$CT). We performed intravital SR$\mu$CT acquisitions of mouse CNS fluid spaces at three synchrotron radiation facilities. Imaging was conducted on both anesthetized free-breathing and ventilated animals, with and without retrospective cardiac gating. We achieved whole-brain imaging at 6.3 $\mu$m uniform voxel size, observed the distribution of cerebrospinal fluid (CSF) contrast agent over time and quantified choroid plexus movement. SR$\mu$CT bridges the gap between multiphoton microscopy and magnetic resonance imaging, offering dynamic imaging with micrometer-scale resolution and whole-organ field of view. Intravital SR$\mu$CT will play a crucial role in validating and integrating hypotheses on CSF dynamics and solute transport by providing unique data that cannot be acquired otherwise.

physics.med-ph

Paradigm Shift in Infrastructure Inspection Technology: Leveraging High-performance Imaging and Advanced AI Analytics to Inspect Road Infrastructure

Effective road infrastructure management is crucial for modern society. Traditional manual inspection techniques remain constrained by cost, efficiency, and scalability, while camera and laser imaging methods fail to capture subsurface defects critical for long-term structural integrity. This paper introduces ROVAI, an end-to-end framework that integrates high-resolution X-ray computed tomography imaging and advanced AI-driven analytics, aiming to transform road infrastructure inspection technologies. By leveraging the computational power of world-leading supercomputers, Fugaku and Frontier, and SoTA synchrotron facility (Spring-8), ROVAI enables scalable and high-throughput processing of massive 3D tomographic datasets. Our approach overcomes key challenges, such as the high memory requirements of vision models, the lack of labeled training data, and storage I/O bottlenecks. This seamless integration of imaging and AI analytics facilitates automated defect detection, material composition analysis, and lifespan prediction. Experimental results demonstrate the effectiveness of ROVAI in real-world scenarios, setting a new standard for intelligent, data-driven infrastructure management.

cs.DC

Murine AI excels at cats and cheese: Structural differences between human and mouse neurons and their implementation in generative AIs

Mouse and human brains have different functions that depend on their neuronal networks. In this study, we analyzed nanometer-scale three-dimensional structures of brain tissues of the mouse medial prefrontal cortex and compared them with structures of the human anterior cingulate cortex. The obtained results indicated that mouse neuronal somata are smaller and neurites are thinner than those of human neurons. These structural features allow mouse neurons to be integrated in the limited space of the brain, though thin neurites should suppress distal connections according to cable theory. We implemented this mouse-mimetic constraint in convolutional layers of a generative adversarial network (GAN) and a denoising diffusion implicit model (DDIM), which were then subjected to image generation tasks using photo datasets of cat faces, cheese, human faces, and birds. The mouse-mimetic GAN outperformed a standard GAN in the image generation task using the cat faces and cheese photo datasets, but underperformed for human faces and birds. The mouse-mimetic DDIM gave similar results, suggesting that the nature of the datasets affected the results. Analyses of the four datasets indicated differences in their image entropy, which should influence the number of parameters required for image generation. The preferences of the mouse-mimetic AIs coincided with the impressions commonly associated with mice. The relationship between the neuronal network and brain function should be investigated by implementing other biological findings in artificial neural networks.

q-bio.NC

Structural aging of human neurons is the opposite of the changes in schizophrenia

Human mentality develops with age and is altered in psychiatric disorders, though their underlying mechanism is unknown. In this study, we analyzed nanometer-scale three-dimensional structures of brain tissues of the anterior cingulate cortex from eight schizophrenia and eight control cases. The distribution profiles of neurite curvature of the control cases showed a trend depending on their age, resulting in an age-correlated decrease in the standard deviation of neurite curvature (Pearson's r = -0.80, p = 0.018). In contrast to the control cases, the schizophrenia cases deviate upward from this correlation, exhibiting a 60% higher neurite curvature compared with the controls (p = 7.8 x 10^(-4)). The neurite curvature also showed a correlation with a hallucination score (Pearson's r = 0.80, p = 1.8 x 10^(-4)), indicating that neurite structure is relevant to brain function. We suggest that neurite curvature plays a pivotal role in brain aging and can be used as a hallmark to exploit a novel treatment of schizophrenia. This nano-CT paper is the result of our decade-long analysis and is unprecedented in terms of number of cases.

q-bio.NC

Full field X-ray Scatter Tomography

In X-ray imaging, photons are transmitted through and absorbed by the subject, but are also scattered in significant quantities. Previous attempts to use scattered photons for biological imaging used pencil or fan beam illumination. Here we present 3D X-ray Scatter Tomography using full-field illumination. Synchrotron imaging experiments were performed of a phantom and the chest of a juvenile rat. Transmitted and scattered photons were simultaneously imaged with separate cameras; a scientific camera directly downstream of the sample stage, and a pixelated detector with a pinhole imaging system placed at 45${}^\circ$ to the beam axis. We obtained scatter tomogram feature fidelity sufficient for segmentation of the lung and major airways in the rat. The image contrast in scatter tomogram slices approached that of transmission imaging, indicating robustness to the amount of multiple scattering present in our case. This opens the possibility of augmenting full-field 2D imaging systems with additional scatter detectors to obtain complementary modes or to improve the fidelity of existing images without additional dose, potentially leading to single-shot or reduced-angle tomography or overall dose reduction for live animal studies.

physics.med-ph

Structural diverseness of neurons between brain areas and between cases

The cerebral cortex is composed of multiple cortical areas that exert a wide variety of brain functions. Although human brain neurons are genetically and areally mosaic, the three-dimensional structural differences between neurons in different brain areas or between the neurons of different individuals have not been delineated. Here, we report a nanometer-scale geometric analysis of brain tissues of the superior temporal gyrus of 4 schizophrenia and 4 control cases by using synchrotron radiation nanotomography. The results of the analysis and a comparison with results for the anterior cingulate cortex indicated that 1) neuron structures are dissimilar between brain areas and that 2) the dissimilarity varies from case to case. The structural diverseness was mainly observed in terms of the neurite curvature that inversely correlates with the diameters of the neurites and spines. The analysis also revealed the geometric differences between the neurons of the schizophrenia and control cases, suggesting that neuron structure is associated with brain function. The area dependency of the neuron structure and its diverseness between individuals should represent the individuality of brain functions.

q-bio.NC

Three-dimensional alteration of neurites in schizophrenia

This paper reports nano-CT analysis of brain tissues of schizophrenia and control cases. The analysis revealed that: (1) neuronal structures vary between individuals, (2) the mean curvature of distal neurites of the schizophrenia cases was 1.5 times higher than that of the controls, and (3) dendritic spines were categorized into two geometrically distinctive groups, though no structural differences were observed between the disease and control cases. The differences in the neurite curvature result in differences in the spatial trajectory and hence alter neuronal circuits. We suggest that the structural alteration of neurons in the schizophrenia cases should reflect psychiatric symptoms of schizophrenia.

q-bio.NC

Synchrotron radiation microtomography of brain hemisphere and spinal cord of a mouse model of multiple sclerosis revealed a correlation between capillary dilation and clinical score

Multiple sclerosis is a neurological disorder in which the myelin sheaths of axons are damaged by the immune response. We report here a three-dimensional structural analysis of brain and spinal cord tissues of a mouse model of multiple sclerosis, known as experimental autoimmune encephalomyelitis (EAE). EAE-induced mice were raised with or without administration of fingolimod, which is used in the treatment of multiple sclerosis. Brains and spinal cords dissected from the EAE mice were lyophilized so as to reconstitute the intrinsic contrast of tissue elements, such as axons, in X-ray images. Three-dimensional structures of the brain hemispheres and spinal cords of the EAE mice were visualized with synchrotron radiation microtomography. Microtomographic cross sections reconstructed from the X-ray images revealed dilation of capillary vessels and vacuolation in the spinal cord of the EAE mice. Vacuolation was also observed in the cerebellum, suggesting that the neuroinflammatory response progressed in the brain. The vessel networks and vacuolation lesions in the spinal cords were modelled by automatically tracing the three-dimensional image in order to analyze the tissue structures quantitatively. The results of the analysis indicated that the distribution of vacuolations was not uniform but three-dimensionally localized. The mean vessel diameter showed a linear correlation with the clinical score, indicating that vasodilation is relevant to paralysis severity in the disease model. We suggest that vasodilation and vacuolation are related with neurological symptoms of multiple sclerosis.

physics.bio-ph

Imaging and spectral performance of CdTe double-sided strip detectors for the Hard X-ray Imager onboard ASTRO-H

The imaging and spectral performance of CdTe double-sided strip detectors (CdTe-DSDs) was evaluated for the ASTRO-H mission. The charcterized CdTe-DSDs have a strip pitch of 0.25 mm, an imaging area of 3.2 cm$\times$3.2 cm and a thickness of 0.75 mm. The detector was successfully operated at a temperature of $-20^\circ$C and with an applied bias voltage of 250 V. By using two-strip events as well as one-strip events for the event reconstruction, a good energy resolution of 2.0 keV at 59.5 keV and a sub-strip spatial resolution was achieved. The hard X-ray and gamma-ray response of CdTe-DSDs is complex due to the properties of CdTe and the small pixel effect. Therefore, one of the issues to investigate is the response of the CdTe-DSD. In order to investigate the spatial dependence of the detector response, we performed fine beam scan experiments at SPring-8, a synchrotron radiation facility. From these experiments, the depth structure of the electric field was determined as well as properties of carriers in the detector and successfully reproduced the experimental data with simulated spectra.

astro-ph.IM

In situ phase contrast X-ray brain CT

Phase contrast X-ray imaging (PCXI) is an emerging imaging modality that has the potential to greatly improve radiography for medical imaging and materials analysis. PCXI makes it possible to visualise soft-tissue structures that are otherwise unresolved with conventional CT by rendering phase gradients in the X-ray wavefield visible. This can improve the contrast resolution of soft tissues structures, like the lungs and brain, by orders of magnitude. Phase retrieval suppresses noise, revealing weakly-attenuating soft tissue structures, however it does not remove the artefacts from the highly attenuating bone of the skull and from imperfections in the imaging system that can obscure those structures. The primary causes of these artefacts are investigated and a simple method to visualise the features they obstruct is proposed, which can easily be implemented for preclinical animal studies. We show that phase contrast X-ray CT (PCXI-CT) can resolve the soft tissues of the brain in situ without a need for contrast agents at a dose $\sim$400 times lower than would be required by standard absorption contrast CT. We generalise a well-known phase retrieval algorithm for multiple-material samples specifically for CT, validate its use for brain CT, and demonstrate its high stability in the presence of noise.

physics.med-ph

Method for estimating modulation transfer function from sample images

The modulation transfer function (MTF) represents the frequency domain response of imaging modalities. Here, we report a method for estimating the MTF from sample images. Test images were generated from a number of images, including those taken with an electron microscope and with an observation satellite. These original images were convolved with point spread functions (PSFs) including those of circular apertures. The resultant test images were subjected to a Fourier transformation. The logarithm of the squared norm of the Fourier transform was plotted against the squared distance from the origin. Linear correlations were observed in the logarithmic plots, indicating that the PSF of the test images can be approximated with a Gaussian. The MTF was then calculated from the Gaussian-approximated PSF. The obtained MTF closely coincided with the MTF predicted from the original PSF. The MTF of an x-ray microtomographic section of a fly brain was also estimated with this method. The obtained MTF showed good agreement with the MTF determined from an edge profile of an aluminum test object. We suggest that this approach is an alternative way of estimating the MTF, independently of the image type.

eess.IV

CT dose reduction factors in the thousands using X-ray phase contrast

Phase-contrast X-ray imaging can improve the visibility of weakly absorbing objects (e.g. soft tissues) by an order of magnitude or more compared to conventional radiographs. Previously, it has been shown that combining phase retrieval with computed tomography (CT) can increase the signal-to-noise ratio (SNR) by up to two orders of magnitude over conventional CT at the same radiation dose, without loss of image quality. Our experiments reveal that as radiation dose decreases, the relative improvement in SNR increases. We discovered this enhancement can be traded for a reduction in dose greater than the square of the gain in SNR. Upon reducing the dose 300 fold, the phase-retrieved SNR was still almost 10 times larger than the absorption contrast data. This reveals the potential for dose reduction factors in the tens of thousands without loss in image quality, which would have a profound impact on medical and industrial imaging applications.

physics.med-ph

Estimating the resolution of real images

Image resolvability is the primary concern in imaging. This paper reports an estimation of the full width at half maximum of the point spread function from a Fourier domain plot of real sample images by neither using test objects, nor defining a threshold criterion. We suggest that this method can be applied to any type of image, independently of the imaging modality.

physics.data-an

Three-dimensional microtomographic imaging of human brain cortex

This paper describes an x-ray microtomographic technique for imaging the three-dimensional structure of the human cerebral cortex. Neurons in the brain constitute a neural circuit as a three-dimensional network. The brain tissue is composed of light elements that give little contrast in a hard x-ray transmission image. The contrast was enhanced by staining neural cells with metal compounds. The obtained structure revealed the microarchitecture of the gray and white matter regions of the frontal cortex, which is responsible for the higher brain functions.

physics.bio-ph

Three-dimensional X-ray visualization of axonal tracts in mouse brain hemisphere

Neurons transmit active potentials through axons, which are essential for the brain to function. In this study, the axonal networks of the murine brain were visualized with X-ray tomographic microscopy, also known as X-ray microtomography or micro-CT. Murine brain samples were freeze-dried to reconstitute the intrinsic contrast of tissue constituents and subjected to X-ray visualization. A whole brain hemisphere visualized by absorption contrast illustrated three-dimensional structures including those of the striatum, corpus callosum, and anterior commissure. Axonal tracts observed in the striatum start from the basal surface of the cerebral cortex and end at various positions in the basal ganglia. The distribution of X-ray attenuation coefficients indicated that differences in water and phospholipid content between the myelin sheath and surrounding tissue constituents account for the observed contrast. A rod-shaped cutout of brain tissue was also analyzed with a phase retrieval method, wherein tissue microstructures could be resolved with up to 2.7 μm resolution. Structures of axonal networks of the striatum were reconstructed by tracing axonal tracts. Such an analysis should be able to delineate the functional relationships of the brain regions involved in the observed network.

physics.bio-ph

X-ray microtomographic visualization of Escherichia coli by metalloprotein overexpression

This paper reports X-ray microtomographic visualization of the microorganism Escherichia coli overexpressing a metalloprotein ferritin. The three-dimensional distribution of linear absorption coefficients determined using a synchrotron radiation microtomograph with a simple projection geometry revealed that the X-ray absorption was homogeneously distributed, suggesting that every E. coli cell was labeled with the ferritin. The ferritin-expressing E. coli exhibited linear absorption coefficients comparable to those of phosphotungstic-acid stained cells. The submicrometer structure of the ferritin-expressing E. coli cells was visualized by Zernike phase contrast using an imaging microtomograph equipped with a Fresnel zone plate. The obtained images revealed curved columnar or bunching oval structures corresponding to the E. coli cells. These results indicate that the metalloprotein overexpression facilitates X-ray visualization of three-dimensional cellular structures of biological objects.

physics.bio-ph

Three-dimensional network of Drosophila brain hemisphere

The first step to understanding brain function is to determine the brain's network structure. We report a three-dimensional analysis of the brain network of the fruit fly Drosophila melanogaster by synchrotron-radiation tomographic microscopy. A skeletonized wire model of the left half of the brain network was built by tracing the three-dimensional distribution of X-ray absorption coefficients. The obtained models of neuronal processes were classified into groups on the basis of their three-dimensional structures. These classified groups correspond to neuronal tracts that send long-range projections or repeated structures of the optic lobe. The skeletonized model is also composed of neuronal processes that could not be classified into the groups. The distribution of these unclassified structures correlates with the distribution of contacts between neuronal processes. This suggests that neurons that cannot be classified into typical structures should play important roles in brain functions. The quantitative description of the brain network provides a basis for structural and statistical analyses of the Drosophila brain. The challenge is to establish a methodology for reconstructing the brain network in a higher-resolution image, leading to a comprehensive understanding of the brain structure.