Searcharxiv⌕ Search

arXiv subjects

Kevin Heijhoff

Publications and source records attributed to Kevin Heijhoff.

5 recordsLinked to original sources

First demonstration of $50\,\mathrm{ps}$ four-dimensional vertex reconstruction with the Timepix4 beam telescope

The first demonstration of 4D vertex reconstruction at the $50\,\mathrm{ps}$ scale using a silicon pixel detector is reported. Hadronic interactions are produced by directing a $180\,\mathrm{GeV}/c$ mixed-hadron beam onto a fixed target upstream of the Timepix4 beam telescope at the CERN SPS. The resulting particles are reconstructed using 4D track and vertex fits that include time directly alongside the spatial parameters. The vertex time resolution follows the expected statistical scaling with the number of timing measurements, reaching $54\pm5\,\mathrm{ps}$ for vertices reconstructed from 16 timing-plane clusters. An irreducible component of $29.2\pm0.6\,\mathrm{ps}$ remains in the fitted resolution model, including sizeable contributions from the clock distribution and the time reference system rather than from the combination of the timing measurements. The observed scaling down to $54\,\mathrm{ps}$ without an unforeseen resolution floor above represents a significant experimental step towards precision-timing in future high-pile-up detectors.

physics.ins-det↗

Neural network-based timewalk correction for the Timepix4 ASIC

Timewalk corrections of hybrid pixel detectors conventionally employ heuristic fits performed independently in bins of the relevant input variables. This requires both an explicit functional ansatz and binning scheme, as well as densely populated calibration data whose required size grows rapidly as further input variables are added. This paper presents a timewalk correction for the Timepix4 readout chip based on a compact feed-forward neural network (NN), which learns the dependence directly from the input variables without requiring an explicit functional ansatz or binning. The NN is compared against the fit-based baseline using data from the Timepix4 beam telescope at the CERN SPS in 2025, with $100\,\mathrm{μm}$ and $300\,\mathrm{μm}$ thick planar sensors. Both methods parameterise the timewalk correction as a function of the measured charge and reconstructed intrapixel impact position. With only 20 % of the calibration data, the NN already achieves the same asymptotic time resolutions as the fit-based baseline: $180\,\mathrm{ps}$ and $300\,\mathrm{ps}$ for the two thicknesses, respectively.

physics.ins-det↗

The Timepix4 Beam Telescope

The spatial and temporal performance of a telescope system comprising planar silicon sensors bump-bonded to Timepix4-v2 ASICs are assessed at the CERN SPS using a $180$~GeV/$c$ mixed hadron beam. The pointing resolution at the centre of the telescope is $2.3 \pm 0.1\;\mathrm{μm}$ and $2.4 \pm 0.1\mathrm{μm}$ in x and y directions, respectively. The temporal resolution for the combined timestamps on a track using only the information from the Timepix4 planes is found to be $92 \pm 5$~ps. The telescope is extensively described including its data acquisition system and dedicated software as well as the corrections applied to the raw measurements.

hep-ex↗

Reconstruction of charged tracks with Timepix4 ASICs

The design of a detector system comprised of four silicon sensors bump-bonded to Timepix4 ASICs is described together with its data acquisition system, operational infrastructure, and dedicated software. The spatial and temporal performance of the system are assessed with a 180 GeV/c mixed hadron beam at the CERN SPS and reported in detail. Particle tracks are reconstructed using time-space measurements from the four detector planes. The spatial hit resolution is assessed to be $(15.5\pm 0.5)$ $μ$m and $(4.5\pm0.3)$ $μ$m for 100 and 300 $μ$m thick sensors, respectively. The timestamps from the detectors are also measured with fine precision, yielding time resolutions of $(452\pm10)$ ps, $(420\pm10)$ ps, $(639\pm10)$ ps, $(631\pm10)$ ps for the two 100 and two 300 $μ$m thick sensors respectively. These measurements are combined to a track time resolution of $(340\pm 5)$ ps.

physics.ins-det↗

Performance of the GridPix detector quad

A gaseous pixel readout module with four GridPix chips, called the quad, has been developed as a building block for a large time projection chamber readout plane. The quad module has dimensions 39.6 mm $\times$ 28.38 mm and an active surface coverage of 68.9%. The GridPix chip consists of a Timepix3 chip with integrated amplification grid and have a high efficiency to detect single ionisation electrons, which enable to make a precise track position measurement. A quad module was installed in a small time projection chamber and measurements of 2.5 GeV electrons were performed at the ELSA accelerator in Bonn, where a silicon telescope was used to provide a reference track. The error on the track position measurement, both in the pixel plane and drift direction, is dominated by diffusion. The quad was designed to have minimum electrical field inhomogeneities and distortions, achieving systematics of better than 13 $μ$m in the pixel plane. The resolution of the setup is 41 $μ$m, where the total systematic error of the quad detector is 24 $μ$m.

physics.ins-det↗