Searcharxiv⌕ Search

arXiv subjects

Kexin Yang

Publications and source records attributed to Kexin Yang.

41 records · Page 3Linked to original sources

XR-Ed Framework: Designing Instruction-driven andLearner-centered Extended Reality Systems for Education

Recently, the HCI community has seen an increased interest in applying Virtual Reality (VR), AugmentedReality (AR) and Mixed Reality (MR) into educational settings. Despite many literature reviews, there stilllacks a clear framework that reveals the different design dimensions in educational Extended Reality (XR)systems. Addressing this gap, we synthesize a broad range of educational XR to propose the XR-Ed framework,which reveals design space in six dimensions (Physical Accessibility, Scenario, Social Interactivity, Agency,Virtuality Degree, Assessment). Within each dimension, we contextualize the framework using existing designcases. Based on the XR-Ed Design framework, we incorporated instructional design approaches to proposeXR-Ins, an instruction-oriented, step-by-step guideline in educational XR instruction design. Jointly, they aimto support practitioners by revealing implicit design choices, offering design inspirations as well as guide themto design instructional activities for XR technologies in a more instruction-oriented and learner-centered way.

cs.HC↗

Magnetocrystalline anisotropy of the easy-plane metallic antiferromagnet Fe$_2$As

Magnetocrystalline anisotropy is a fundamental property of magnetic materials that determines the dynamics of magnetic precession, the frequency of spin waves, the thermal stability of magnetic domains, and the efficiency of spintronic devices. We combine torque magnetometry and density functional theory calculations to determine the magnetocrystalline anisotropy of the metallic antiferromagnet Fe$_2$As. Fe$_2$As has a tetragonal crystal structure with the Néel vector lying in the (001) plane. We report that the four-fold magnetocrystalline anisotropy in the (001)-plane of Fe$_2$As is extremely small, ${K_{22}} = - 150~{\rm{ J/}}{\rm{m}^{\rm{3}}}$ at T = 4 K, much smaller than perpendicular magnetic anisotropy of ferromagnetic structure widely used in spintronics device. ${K_{22}}$ is strongly temperature dependent and close to zero at T > 150 K. The anisotropy ${K_1}$ in the (010) plane is too large to be measured by torque magnetometry and we determine ${K_1} = -830~{\rm{ kJ/}}{\rm{m}^{\rm{3}}}$ using first-principles density functional theory. Our simulations show that the contribution to the anisotropy from classical magnetic dipole-dipole interactions is comparable to the contribution from spin-orbit coupling. The calculated four-fold anisotropy in the (001) plane ${K_{22}}$ ranges from $- 292~{\rm{ J/}}{\rm{m}^{\rm{3}}}$ to $280~{\rm{ J/}}{\rm{m}^{\rm{3}}}$, the same order of magnitude as the measured value. We use ${K_1}$ from theory to predict the frequency and polarization of the lowest frequency antiferromagnetic resonance mode and find that the mode is linearly polarized in the (001)-plane with $f = $ 670 GHz.

cond-mat.mtrl-sci↗

Preliminary prediction of the basic reproduction number of the Wuhan novel coronavirus 2019-nCoV

Objectives.--To estimate the basic reproduction number of the Wuhan novel coronavirus (2019-nCoV). Methods.--Based on the susceptible-exposed-infected-removed (SEIR) compartment model and the assumption that the infectious cases with symptoms occurred before January 25, 2020 are resulted from free propagation without intervention, we estimate the basic reproduction number of 2019-nCoV according to the reported confirmed cases and suspected cases, as well as the theoretical estimated number of infected cases by other research teams, together with some epidemiological determinants learned from the severe acute respiratory syndrome. Results The basic reproduction number falls between 2.8 to 3.3 by using the real-time reports on the number of 2019-nCoV infected cases from People's Daily in China, and falls between 3.2 and 3.9 on the basis of the predicted number of infected cases from colleagues. Conclusions.--The early transmission ability of 2019-nCoV is closed to or slightly higher than SARS. It is a controllable disease with moderate-high transmissibility. Timely and effective control measures are needed to suppress the further transmissions. Notes Added.--Using a newly reported epidemiological determinants for early 2019-nCoV, the estimated basic reproduction number is in the range [2.2,3.0].

q-bio.PE↗

Magneto-optic Response of the Metallic Antiferromagnet Fe$_{2}$As to Ultrafast Temperature Excursions

The linear magneto-optical Kerr effect (MOKE) is often used to probe magnetism of ferromagnetic materials, but MOKE cannot be applied to collinear antiferromagnets (AFs) due to the cancellation of sub-lattice magnetization. Magneto-optical constants that are quadratic in magnetization, however, provide an approach for studying AFs on picosecond time scales. Here, we combine transient measurements of optical reflectivity and birefringence to study the linear optical response of Fe$_{2}$As to small ultrafast temperature excursions. We performed temperature dependent pump-probe measurements on crystallographically isotropic (001) and anisotropic (010) faces of Fe$_{2}$As bulk crystals. We find the largest optical signals arise from changes in the index of refraction along the $z$-axis, i.e. perpendicular to the Néel vector. Both real and imaginary parts of the time-resolved optical birefringence rotation signal approximately follow the temperature dependence of the magnetic heat capacity, as expected if the changes in dielectric constants are dominated by contributions of exchange interactions to the dielectric constant. We conclude that under our experimental conditions, changes in the exchange interaction contribute more strongly to the temperature dependence of the magneto-optic constants than the Voigt effect.

cond-mat.mtrl-sci↗

Ancient-Modern Chinese Translation with a Large Training Dataset

Ancient Chinese brings the wisdom and spirit culture of the Chinese nation. Automatic translation from ancient Chinese to modern Chinese helps to inherit and carry forward the quintessence of the ancients. However, the lack of large-scale parallel corpus limits the study of machine translation in Ancient-Modern Chinese. In this paper, we propose an Ancient-Modern Chinese clause alignment approach based on the characteristics of these two languages. This method combines both lexical-based information and statistical-based information, which achieves 94.2 F1-score on our manual annotation Test set. We use this method to create a new large-scale Ancient-Modern Chinese parallel corpus which contains 1.24M bilingual pairs. To our best knowledge, this is the first large high-quality Ancient-Modern Chinese dataset. Furthermore, we analyzed and compared the performance of the SMT and various NMT models on this dataset and provided a strong baseline for this task.

cs.CL↗