Structural Analysis and Internal Stability Enhancement of Virtual-Admittance-Based Cascaded GFMIs Under Unity Voltage-Feedback Decoupling

Virtual admittance (VA) is widely used in cascaded voltage-control and current-control (VC-CC) grid-forming inverters (GFMIs) because it shapes the converter terminal behavior while preserving the current-regulation path required for current shaping and limiting. However, the achievable VC-loop bandwidth remains strongly coupled to the CC-loop bandwidth and to the VA parameters. Voltage-feedback decoupling (VFD) is commonly used to relax this coupling, but in VA-based control its benefit is not unconditional. This paper shows that unity-gain VFD, which represents the full-decoupling condition, removes the low-frequency restoring term associated with the filter capacitor and drives the voltage loop toward a delay-sensitive double-integrator structure. This internal-stability limitation is referred to here as the VFD trap. To address this trap without attenuating VFD, a proportional active-damping (AD) path is proposed, implemented as negative capacitor-voltage feedback in the current-reference path. The proposed path restores the missing low-frequency support while retaining unity VFD and introduces an additional AD-based degree of freedom for VC-loop tuning. A minimum support condition, a delay-aware phase-margin expression, and compact forward/inverse design equations are derived for operating-point selection. Standalone and grid-connected experiments on a 3-kVA prototype verify the analysis, showing that the proposed path recovers stable unity-VFD operation, reduces the voltage-step settling time from approximately 9~ms to 3~ms, and maintains stable power injection.

eess.SY

Decoupled Internal Energy Regulation and Inertial Response Provision for Grid-Forming Multilevel-Converter-Based E-STATCOMs

As power systems accommodate higher shares of renewable generation, short-term power imbalances become more frequent and can manifest as pronounced voltage and frequency excursions under low-inertia conditions. E-STATCOMs (STATCOMs equipped with energy storage) offer a practical means to provide both voltage support and fast frequency assistance under grid-forming control. Among candidate implementations, double-star multilevel-converter (DS-MC)-based E-STATCOMs enable centralized energy-storage integration at the dc link, which improves thermal management and maintainability. Nevertheless, conventional dc-side power-based internal-energy regulation in DS-MCs can undesirably couple loss compensation to the energy-storage path, accelerating storage cycling and constraining operation when the storage is unavailable. This paper introduces a control strategy that assigns DS-MC total internal-energy regulation to the ac-side active-power path, while reserving dc-side storage power solely for frequency support. By decoupling internal-energy management from inertial-response provision, the proposed scheme enables flexible operation as either a STATCOM or an E-STATCOM according to storage availability and mitigates unnecessary storage cycling. The proposed strategy is verified through offline simulations and laboratory-scale experiments.

eess.SY

Transient Stability Analysis of Grid-Forming Converters with Current Limiting Considering Asymmetrical Grid Faults

Under asymmetrical faults, analyzing the transient stability of grid-forming voltage-source converters (GFM-VSCs) becomes essential because their behavior fundamentally differs from that under symmetrical faults. When current limiting is activated under asymmetrical faults, the point-of-common-coupling voltage of a GFM-VSC contains both positive- and negative-sequence components, and the interaction between these components generates a non-negligible negative-sequence-driven active power. However, the transient stability of GFM-VSCs under asymmetrical faults has not been sufficiently investigated, and the influence of negative-sequence-driven active power remains unclear. Accordingly, this letter derives the P-δ curve of a GFM-VSC with an elliptical current limiter under asymmetrical faults by explicitly accounting for negative-sequence effects. This enables a more accurate transient stability assessment when extending conventional symmetrical-fault analyses to asymmetrical conditions. The theoretical analysis is validated by the agreement between the derived P-δ curve and both simulation and experimental results.

eess.SY