SearcharxivSearch

arXiv subjects

Kian Shaker

Publications and source records attributed to Kian Shaker.

3 recordsLinked to original sources

Fast and Scalable Production of Stacked Prism X-ray Lenses for Astrophysics Using Two-Photon Polymerization

Stacked prism lenses (SPLs) are a type of refractive X-ray optics currently under development with the potential to greatly improve on current X-ray telescope optics in terms of focal length, angular resolution, efficiency and scalability. For this work, SPLs are manufactured using two-photon polymerization (2PP), with production being significantly faster and with higher geometric fidelity than previous methods. Preliminary laboratory tests show improved efficiency compared to previous manufacturing methods and promising optical capabilities. Two-photon polymerization is shown to be a reliable method for producing SPLs, and when challenges around printing time and assembly are addressed, the path towards an SPL X-ray telescope lies open.

astro-ph.IM

Towards low-cost lead screening with transmission XRF

Human exposure to lead (Pb) is a global health concern, yet existing technologies for detecting lead in our environment remain prohibitively expensive for widespread deployment. Here we present a new concept towards lead screening using X-ray fluorescence (XRF) in an unconventional geometry we coin transmission XRF in which the sample is placed between the source and detector. For cost reduction, we then show that $^{241}$Am found in ionizing smoke detectors is spectrally suitable for Pb L-shell XRF generation and can thus replace X-ray tubes used in conventional XRF devices. Exploring soil screening as the first application, we demonstrate with Monte Carlo simulations that a configuration with 7$\times$ $^{241}$Am sources and a standard silicon drift detector can enable screening-relevant detection limits (100 ppm Pb) in soil within practical measurement times (<30 min). We believe this concept opens a route toward low-cost and scalable XRF instrumentation for democratizing lead screening across a wide range of samples.

physics.ins-det

OpenDosimeter: Open Hardware Personal X-ray Dosimeter

We present OpenDosimeter (www.opendosimeter.org), an open hardware solution for real-time personal X-ray dose monitoring based on a scintillation counter. Using an X-ray sensor assembly (LYSO + SiPM) on a custom board powered by a Raspberry Pi Pico, OpenDosimeter provides real-time feedback (1 Hz), data logging (10 hours), and battery-powered operation. One of the core innovations is that we calibrate the device using $^{241}$Am found in ionization smoke detectors. Specifically, we use the $\gamma$-emissions to spectrally calibrate the dosimeter, then calculate the effective dose from X-ray exposure by compensating for the scintillator absorption efficiency and applying energy-to-dose coefficients derived from tabulated data in the ICRP 116 publication. We demonstrate that this transparent approach enables real-time dose rate readings with a linear response between 0.1-1000 $\mu$Sv/h at $\pm$25% accuracy, tested for energies up to 120 keV. The maximum dose rate readings are limited by pile-up effects when approaching count rate saturation ($\sim$77 kcps at $\sim$13 $\mu$s average pulse processing time). The total component cost for making an OpenDosimeter is <\$100, which, combined with its open design (both hardware and software), enables cost-effective local reproducibility on a global scale. Through a student workshop, we also demonstrate its effectiveness as an educational and capacity-building tool. This paper complements the open-source documentation by explaining the underlying technology, the algorithm for dose calculation, and areas for future improvement.

physics.ins-det