Searcharxiv⌕ Search

arXiv subjects

Kibrom Gebremedhin

Publications and source records attributed to Kibrom Gebremedhin.

2 recordsLinked to original sources

Comparative Performance and Parameter-Efficient Adaptation of DINOv2 for Active Trachoma Classification

Automated grading of conjunctival photographs could reduce the cost and variability of trachoma prevalence surveys, but the relative value of modern pretrained visual representations, lightweight feature adaptation, and training-objective design has not been established under a common protocol. This study presents a controlled evaluation for binary classification of Trachomatous Inflammation-Follicular (TF) versus Normal using 1,546 images from the public UCSF/Lietman collection. Images are processed using the OPTED pipeline for zero-shot tarsal-conjunctiva segmentation, alignment, cropping, and standardization. We first compare six pretrained backbones using a common classification pipeline and then evaluate four lightweight adaptation mechanisms on DINOv2 ViT-B/14. Under stratified five-fold cross-validation, DINOv2 with Efficient Channel Attention (ECA) and focal-plus-center loss achieved 91.66 +/- 0.97% accuracy, 90.69 +/- 1.10% macro-F1, and 96.06 +/- 0.71% AUC. ECA introduces only five learnable parameters while matching the performance of substantially larger alternatives. Objective ablation further showed that ECA did not consistently improve plain DINOv2 across loss functions; the lowest-variance 91.66% accuracy was obtained with cross-entropy plus center loss. Overall, the fine-tuned DINOv2 representation provided most of the predictive performance, while ECA offered a highly parameter-efficient refinement whose effect depended on the training objective. The resulting workflow provides a reproducible benchmark for active trachoma image classification.

cs.CV↗

OPTED: Open Preprocessed Trachoma Eye Dataset Using Zero-Shot SAM 3 Segmentation

Trachoma remains the leading infectious cause of blindness worldwide, with Sub-Saharan Africa bearing over 85% of the global burden and Ethiopia alone accounting for more than half of all cases. Yet publicly available preprocessed datasets for automated trachoma classification are scarce, and none originate from the most affected region. Raw clinical photographs of eyelids contain significant background noise that hinders direct use in machine learning pipelines. We present OPTED, an open-source preprocessed trachoma eye dataset constructed using the Segment Anything Model 3 (SAM 3) for automated region-of-interest extraction. We describe a reproducible four-step pipeline: (1) text-prompt-based zero-shot segmentation of the tarsal conjunctiva using SAM 3, (2) background removal and bounding-box cropping with alignment, (3) quality filtering based on confidence scores, and (4) Lanczos resizing to 224x224 pixels. A separate prompt-selection stage identifies the optimal text prompt, and manual quality assurance verifies outputs. Through comparison of five candidate prompts on all 2,832 known-label images, we identify "inner surface of eyelid with red tissue" as optimal, achieving a mean confidence of 0.872 (std 0.070) and 99.5% detection rate (the remaining 13 images are recovered via fallback prompts). The pipeline produces outputs in two formats: cropped and aligned images preserving the original aspect ratio, and standardized 224x224 images ready for pre-trained architectures. The OPTED dataset, preprocessing code, and all experimental artifacts are released as open source to facilitate reproducible trachoma classification research.

cs.CV↗