SearcharxivSearch

arXiv subjects

Kim Butts Pauly

Publications and source records attributed to Kim Butts Pauly.

9 recordsLinked to original sources

ITRUSST Consensus on Biophysical Safety for Transcranial Ultrasound Stimulation

Transcranial ultrasound stimulation (TUS) is an emerging technology for non-invasive brain stimulation. The International Transcranial Ultrasonic Stimulation Safety and Standards consortium (ITRUSST) has established consensus on considerations for nonsignificant biophysical risk of TUS, drawing upon the literature and established regulations for biomedical devices. Here, we assume the application of TUS to individuals without contraindications, compromised thermoregulation, vascular vulnerabilities, or administered ultrasound contrast agents. In this context, we present a concise yet comprehensive set of levels for nonsignificant risks of TUS application. For mechanical effects, it is non-significant risk if the mechanical index (MI) or the mechanical index for transcranial application (MItc) does not exceed 1.9. For thermal effects, it is non-significant risk if any of the following three levels are met: the peak temperature rise does not exceed 2°C or the peak absolute temperature does not exceed 39°C, assuming a baseline temperature of 37°C, the thermal dose does not exceed 2 CEM43 in brain tissue, 16 CEM43 in bone tissue, and 21 CEM43 in skin tissue, or specific values of the thermal index (TI) for a given exposure time. This report reflects a consensus expert opinion and can inform, but not replace, regulatory guidelines or official international standards. Similarly, this consensus can inform, but not replace, ethical evaluation, which weighs the total burden, risks, and benefits of the proposed action. The stated levels are not safety limits per se, and further data is needed to establish the threshold for significant risk. We review literature relevant to our considerations and discuss limitations and future developments of our approach.

physics.bio-ph

A Practical Guide to Transcranial Ultrasonic Stimulation from the IFCN-endorsed ITRUSST Consortium

Low-intensity Transcranial Ultrasonic Stimulation (TUS) is a non-invasive brain stimulation technique enabling cortical and deep brain targeting with unprecedented spatial accuracy. Given the high rate of adoption by new users with varying levels of expertise and interdisciplinary backgrounds, practical guidelines are needed to ensure state-of-the-art TUS application and reproducible outcomes. Therefore, the International Transcranial Ultrasonic Stimulation Safety and Standards (ITRUSST) consortium has formed a subcommittee, endorsed by the International Federation of Clinical Neurophysiology (IFCN), to develop recommendations for best practice in TUS applications in humans. The practical guide presented here provides a brief introduction into ultrasound physics and sonication parameters. It explains the requirements of TUS lab equipment and transducer selection and discusses experimental design and procedures alongside potential confounds and control conditions. Finally, the guide elaborates on essential steps of application planning for stimulation safety and efficacy, as well as considerations when combining TUS with neuroimaging, electrophysiology, or other brain stimulation techniques. We hope that this practical guide to TUS will assist both novice and experienced users in planning and conducting high-quality studies and provide a solid foundation for further advancements in this promising field.

physics.med-ph

A deep-learning model for one-shot transcranial ultrasound simulation and phase aberration correction

Transcranial ultrasound (TUS) has emerged as a promising tool in clinical and research settings due to its potential to modulate neuronal activity, open the blood-brain barrier, facilitate targeted drug delivery via nanoparticles, and perform thermal ablation, all non-invasively. By delivering focused ultrasound waves to precise regions anywhere in the brain, TUS enables targeted energy deposition and is being explored in over fifty clinical trials as a treatment for conditions such as opioid addiction, Alzheimer's disease, dementia, epilepsy, and glioblastoma. However, effective TUS treatment requires careful ultrasound parameter design and precise computation of the focal spot's location and pressure, as skull heterogeneity increases the risk of off-target sonication or insufficient energy delivery to neural tissue. In clinical settings, this phase aberration correction must be computed within seconds. To achieve this, commercial devices often rely on faster methods, such as ray tracing, to predict the focus location and pressure. While computationally efficient, these methods may not always provide the high level of accuracy needed for optimal TUS delivery. We present TUSNet, the first end-to-end deep learning approach to solve for both the pressure field and phase aberration corrections without being bound to the inherent trade-off between accuracy and efficiency. TUSNet computes the 2D transcranial ultrasound pressure field and phase corrections within 21 milliseconds (over $1200\times$ faster than k-Wave, a MATLAB-based acoustic simulation package), achieving $98.3\%$ accuracy in estimating peak pressure magnitude at the focal spot with a mean positioning error of only $0.18$ mm compared to ground truth from k-Wave.

physics.med-ph

Focal Volume, Acoustic Radiation Force, and Strain in Two-Transducer Regimes

Transcranial focused ultrasound stimulation (TUS) holds promise for non-invasive neural modulation in treating neurological disorders. Most clinically relevant targets are deep within the brain (near or at its geometric center), surrounded by other sensitive regions that need to be spared clinical intervention. However, in TUS, increasing frequency with the goal of improving spatial resolution reduces the effective penetration depth. We show that by using a pair of 1 MHz, orthogonally arranged transducers we improve the spatial resolution afforded by each of the transducers individually, by nearly 40 fold, achieving a sub-cubic millimeter target volume of $0.24\ mm^3$. We show that orthogonally placed transducers generate highly localized standing waves with Acoustic Radiation Force (ARF) arranged into periodic regions of compression and tension near the target. We further present an extended capability of the orthogonal setup, which is to impart selective pressures--either positive or negative, but not both--on the target. Lastly, we share our preliminary findings that strain can arise from both particle motion and ARF with the former reaching its maximum value at the focus, and the latter remaining null at the focus and reaching its maximum around the focus. As the field is investigating the mechanism of interaction in TUS by way of elucidating the mapping between ultrasound parameters and neural response, orthogonal transducers expand our toolbox by making it possible to conduct these investigations at much finer spatial resolutions, with localized and directed (compression vs. tension) ARF and the capability of applying selective pressures at the target.

physics.app-ph

Biophysical effects and neuromodulatory dose of transcranial ultrasonic stimulation

Transcranial ultrasonic stimulation (TUS) has the potential to usher in a new era for human neuroscience by allowing spatially precise and high-resolution non-invasive targeting of both deep and superficial brain regions. Currently, fundamental research on the mechanisms of interaction between ultrasound and neural tissues is progressing in parallel with application-focused research. However, a major hurdle in the wider use of TUS is the selection of optimal parameters to enable safe and effective neuromodulation in humans. In this paper, we will discuss the major factors that determine both the safety and efficacy of TUS. We will discuss the thermal and mechanical biophysical effects of ultrasound, which underlie its biological effects, in the context of their relationships with tunable parameters. Based on this knowledge of biophysical effects, and drawing on concepts from radiotherapy, we propose a framework for conceptualising TUS dose.

physics.bio-ph

The relationship between parameters and effects in transcranial ultrasonic stimulation

Transcranial ultrasonic stimulation (TUS) is rapidly gaining traction for non-invasive human neuromodulation, with a pressing need to establish protocols that maximise neuromodulatory efficacy. In this review, we aggregate and examine empirical evidence for the relationship between tunable TUS parameters and in vitro and in vivo outcomes. Based on this multiscale approach, TUS researchers can make better informed decisions about optimal parameter settings. Importantly, we also discuss the challenges involved in extrapolating results from prior empirical work to future interventions, including the translation of protocols between models and the complex interaction between TUS protocols and the brain. A synthesis of the empirical evidence suggests that larger effects will be observed at lower frequencies within the sub-MHz range, higher intensities and pressures than commonly administered thus far, and longer pulses and pulse train durations. Nevertheless, we emphasise the need for cautious interpretation of empirical data from different experimental paradigms when basing protocols on prior work as we advance towards refined TUS parameters for human neuromodulation.

physics.bio-ph

ITRUSST Consensus on Standardised Reporting for Transcranial Ultrasound Stimulation

As transcranial ultrasound stimulation (TUS) advances as a precise, non-invasive neuromodulatory method, there is a need for consistent reporting standards to enable comparison and reproducibility across studies. To this end, the International Transcranial Ultrasonic Stimulation Safety and Standards Consortium (ITRUSST) formed a subcommittee of experts across several domains to review and suggest standardised reporting parameters for low intensity TUS, resulting in the guide presented here. The scope of the guide is limited to reporting the ultrasound aspects of a study. The guide and supplementary material provide a simple checklist covering the reporting of: (1) the transducer and drive system, (2) the drive system settings, (3) the free field acoustic parameters, (4) the pulse timing parameters, (5) \emph{in situ} estimates of exposure parameters in the brain, and (6) intensity parameters. Detailed explanations for each of the parameters, including discussions on assumptions, measurements, and calculations, are also provided.

physics.med-ph

Synthetic Skull CT Generation with Generative Adversarial Networks to Train Deep Learning Models for Clinical Transcranial Ultrasound

Deep learning offers potential for various healthcare applications, yet requires extensive datasets of curated medical images where data privacy, cost, and distribution mismatch across various acquisition centers could become major problems. To overcome these challenges, we propose a generative adversarial network (SkullGAN) to create large datasets of synthetic skull CT slices, geared towards training models for transcranial ultrasound. With wide ranging applications in treatment of essential tremor, Parkinson's, and Alzheimer's disease, transcranial ultrasound clinical pipelines can be significantly optimized via integration of deep learning. The main roadblock is the lack of sufficient skull CT slices for the purposes of training, which SkullGAN aims to address. Actual CT slices of 38 healthy subjects were used for training. The generated synthetic skull images were then evaluated based on skull density ratio, mean thickness, and mean intensity. Their fidelity was further analyzed using t-distributed stochastic neighbor embedding (t-SNE), Fréchet inception distance (FID) score, and visual Turing test (VTT) taken by four staff clinical radiologists. SkullGAN-generated images demonstrated similar quantitative radiological features to real skulls. t-SNE failed to separate real and synthetic samples from one another, and the FID score was 49. Expert radiologists achieved a 60\% mean accuracy on the VTT. SkullGAN makes it possible for researchers to generate large numbers of synthetic skull CT segments, necessary for training neural networks for medical applications involving the human skull, such as transcranial focused ultrasound, mitigating challenges with access, privacy, capital, time, and the need for domain expertise.

eess.IV

Benchmark problems for transcranial ultrasound simulation: Intercomparison of compressional wave models

Computational models of acoustic wave propagation are frequently used in transcranial ultrasound therapy, for example, to calculate the intracranial pressure field or to calculate phase delays to correct for skull distortions. To allow intercomparison between the different modeling tools and techniques used by the community, an international working group was convened to formulate a set of numerical benchmarks. Here, these benchmarks are presented, along with intercomparison results. Nine different benchmarks of increasing geometric complexity are defined. These include a single-layer planar bone immersed in water, a multi-layer bone, and a whole skull. Two transducer configurations are considered (a focused bowl and a plane piston), giving a total of 18 permutations of the benchmarks. Eleven different modeling tools are used to compute the benchmark results. The models span a wide range of numerical techniques, including the finite-difference time-domain method, angular-spectrum method, pseudospectral method, boundary-element method, and spectral-element method. Good agreement is found between the models, particularly for the position, size, and magnitude of the acoustic focus within the skull. When comparing results for each model with every other model in a cross comparison, the median values for each benchmark for the difference in focal pressure and position are less than 10\% and 1 mm, respectively. The benchmark definitions, model results, and intercomparison codes are freely available to facilitate further comparisons.

physics.comp-ph