Evaluation of Silicon-Based Photon-Counting CT for Coronary Stenosis Quantification with Realistic Coronary Artery Phantoms

Objective: To quantify the impact of high-resolution deep silicon photon-counting CT (dSi-PCCT) on coronary stenosis quantification in anatomically realistic calcified coronary artery phantoms using Micro-CT as ground truth. Methods: Twelve vessel sections representing four calcification geometries (Type I-IV) and three luminal iodine concentrations (10, 15, and 20 mg/mL) were scanned under static conditions using energy-integrating detector CT (EID-CT), dSi-PCCT, and Micro-CT. Images were registered to Micro-CT and segmented using an automated threshold-based pipeline. The primary analysis compared longitudinal profiles of Micro-CT-referenced percent area stenosis and segmented vessel area. A secondary analysis evaluated ellipse-derived percent area stenosis and percent vessel-area deviation at the maximum-calcification cross-section. Results: dSi-PCCT reduced whole-profile mean absolute error in Micro-CT-referenced percent area stenosis from 3.10% with EID-CT to 1.62% (p=0.027) and reduced segmented vessel-area error from 0.55 to 0.31 mm2 (p=0.001). In the secondary analysis, absolute deviations in ellipse-derived percent area stenosis ranged from 0.1% to 6.5% for dSi-PCCT and from 0.8% to 24.2% for EID-CT (p<0.001). Mean absolute differences in percent vessel-area deviation from Micro-CT were also lower with dSi-PCCT than with EID-CT (15.0% vs 26.6%, p<0.001). Conclusion: Under static, resolution-optimized conditions, dSi-PCCT improved task-based coronary stenosis quantification and vessel delineation relative to EID-CT, supporting further evaluation in dynamic phantoms and clinical CCTA.

physics.med-ph

Personalized and uncertainty-aware coronary hemodynamics simulations: From Bayesian estimation to improved multi-fidelity uncertainty quantification

Simulations of coronary hemodynamics have improved non-invasive clinical risk stratification and treatment outcomes for coronary artery disease, compared to relying on anatomical imaging alone. However, simulations typically use empirical approaches to distribute total coronary flow amongst the arteries in the coronary tree. This ignores patient variability, the presence of disease, and other clinical factors. Further, uncertainty in the clinical data often remains unaccounted for in the modeling pipeline. We present an end-to-end uncertainty-aware pipeline to (1) personalize coronary flow simulations by incorporating branch-specific coronary flows as well as cardiac function; and (2) predict clinical and biomechanical quantities of interest with improved precision, while accounting for uncertainty in the clinical data. We assimilate patient-specific measurements of myocardial blood flow from CT myocardial perfusion imaging to estimate branch-specific coronary flows. We use adaptive Markov Chain Monte Carlo sampling to estimate the joint posterior distributions of model parameters with simulated noise in the clinical data. Additionally, we determine the posterior predictive distribution for relevant quantities of interest using a new approach combining multi-fidelity Monte Carlo estimation with non-linear, data-driven dimensionality reduction. Our framework recapitulates clinically measured cardiac function as well as branch-specific coronary flows under measurement uncertainty. We substantially shrink the confidence intervals for estimated quantities of interest compared to single-fidelity and state-of-the-art multi-fidelity Monte Carlo methods. This is especially true for quantities that showed limited correlation between the low- and high-fidelity model predictions. Moreover, the proposed estimators are significantly cheaper to compute for a specified confidence level or variance.

physics.flu-dyn

A coronary artery phantom for task-based CT performance assessment and a comparative study of clinical CT, photon counting CT, and micro CT

While drastic improvements in CT technology have occurred in the past 25 years, spatial resolution is one area where progress has been limited until recently. New photon counting CT systems, are capable of much better spatial resolution than their (energy integrating) predecessors. These improvements have the potential to improve the evaluation obstructive coronary artery disease by enabling more accurate delineation between calcified plaque and coronary vessel lumen. A new set of vessel phantoms has been designed and manufactured for quantifying this improvement. Comparisons are made between an existing clinical CT system, a prototype photon counting system, with images from a micro CT system being used as the gold standard. Scans were made of the same objects on all three systems. The resulting images were registered and the luminal cross section areas were compared. Luminal cross-sections near calcified plaques were reduced due to blooming, but this effect was much less pronounced in images from the prototype photon counting system as compared to the images from the clinical CT system.

physics.med-ph

Coronary Atherosclerotic Plaque Characterization with Photon-counting CT: a Simulation-based Feasibility Study

Recent development of photon-counting CT (PCCT) brings great opportunities for plaque characterization with much-improved spatial resolution and spectral imaging capability. While existing coronary plaque PCCT imaging results are based on detectors made of CZT or CdTe materials, deep-silicon photon-counting detectors have unique performance characteristics and promise distinct imaging capabilities. In this work, we report a systematic simulation study of a deep-silicon PCCT scanner with a new clinically-relevant digital plaque phantom with realistic geometrical parameters and chemical compositions. This work investigates the effects of spatial resolution, noise, motion artifacts, radiation dose, and spectral characterization. Our simulation results suggest that the deep-silicon PCCT design provides adequate spatial resolution for visualizing a necrotic core and quantitation of key plaque features. Advanced denoising techniques and aggressive bowtie filter designs can keep image noise to acceptable levels at this resolution while keeping radiation dose comparable to that of a conventional CT scan. The ultrahigh resolution of PCCT also means an elevated sensitivity to motion artifacts. It is found that a tolerance of less than 0.4 mm residual movement range requires the application of accurate motion correction methods for best plaque imaging quality with PCCT.

physics.med-ph