Searcharxiv⌕ Search

arXiv subjects

Kohei Yorita

Publications and source records attributed to Kohei Yorita.

7 recordsLinked to original sources

Low-Noise SiPM Light Readout and ASIC-Based Charge Readout of a Liquid Argon Time Projection Chamber for MeV Gamma-Ray Measurements

We have developed a compact liquid argon time projection chamber (LArTPC), NanoGRAMS, as a technology demonstrator for the Gamma-Ray and AntiMatter Survey (GRAMS). LArTPCs have the potential to enable Compton cameras with unprecedented effective area in the MeV gamma-ray band. NanoGRAMS has an active volume of $5.12 \times 5.12 \times 10~\mathrm{cm^3}$ and is equipped with a low-noise scintillation and charge readout system. The scintillation light is detected by an array of 16 SiPMs ($6 \times 6~\mathrm{mm^2}$ each), whose signals are summed and amplified by a low-noise transimpedance amplifier operable at liquid argon temperature. Ionization electrons are read out with $3.2\,\mathrm{mm}$-pitch pixels and processed by VATA-SGD ASICs, with synchronization provided by an FPGA-based data acquisition system. We irradiated the detector with a $^{60}\mathrm{Co}$ source (1173 and $1332\,\mathrm{keV}$) and successfully detected both 1-hit and 2-hit events. The collected charge was converted to deposited energy using a phenomenological recombination model, and the detector response was evaluated with a Geant4-based Monte Carlo simulation. The reconstructed energy spectrum shows Compton edges at 963 and $1118\,keV$, consistent with the expected values. For 2-hit events, the sequence of interactions was identified, and the reconstructed back-projection image agrees with the source position. These results demonstrate the feasibility of NanoGRAMS as a Compton camera for MeV gamma-ray imaging spectroscopy.

astro-ph.IM↗

Reconstruction of multiple Compton scattering events in MeV gamma-ray Compton telescopes towards GRAMS: the physics-based probabilistic model

Aimed at progress in mega-electron volt (MeV) gamma-ray astronomy, which has not yet been well-explored, Compton telescope missions with a variety of detector concepts have been proposed so far. One of the key techniques for these future missions is an event reconstruction algorithm that is able to determine the scattering orders of multiple Compton scattering events and to identify events in which gamma rays escape from the detectors before they deposit all of their energies. We revisit previous event reconstruction methods and propose a modified algorithm based on a probabilistic method. First, we present a general formalism of the probabilistic model of Compton scattering describing physical interactions inside the detector and measurement processes. Then, we also introduce several approximations in the calculation of the probability functions for efficient computation. For validation, the developed algorithm has been applied to simulation data of a Compton telescope using a liquid argon time projection chamber, which is a new type of Compton telescope proposed for the GRAMS project. We have confirmed that it works successfully for up to 8-hit events, including correction of incoming gamma-ray energies for escape events. The proposed algorithm can be used for next-generation MeV gamma-ray missions featured by large-volume detectors, e.g., GRAMS.

astro-ph.IM↗

Measurement of emission spectrum for gaseous argon electroluminescence in visible light region from 300 to 600 nm

A double-phase Ar detector can efficiently identify particles and reconstruct their positions. However, the properties of electroluminescence (EL) for secondary light emission in the gas phase are not fully understood. Earlier studies have explained the EL process using an ordinary EL mechanism because of an Ar excimer; however, this mechanism does not predict the emission of visible light (VL). Recent measurements have demonstrated VL components in Ar gas EL, to explain which a new mechanism called neutral bremsstrahlung (NBrS) was proposed. In this study, we investigated gaseous Ar EL in the VL region from 300 to 600 nm at room temperature and normal pressure using a gaseous time projection chamber (TPC). The secondary emission light from the TPC luminescence region was dispersed using a spectrometer. The observed spectrum was interpreted using the ordinary EL and NBrS models, and the effect of nitrogen impurities is discussed herein.

physics.ins-det↗

Development of a high-light-yield liquid argon detector using tetraphenyl butadiene and silicon photomultiplier array

To increase the light yield of a liquid Ar (LAr) detector, we optimized the evaporation technique of tetraphenyl butadiene (TPB) on the detector surface and tested the operability of a silicon photomultiplier (SiPM), namely, the multi-pixel photon counter with through-silicon-via (TSV-MPPC, Hamamatsu Photonics K.K.) at LAr temperature. TPB converts the LAr scintillations (vacuum ultraviolet light) to visible light, which can be detected by high-sensitivity photosensors. Because the light yield depends on the deposition mass of TPB on the inner surface of the detector, we constructed a well-controlled TPB evaporator to ensure reproducibility and measured the TPB deposition mass using a quartz crystal microbalance sensor. After optimizing the deposition mass of TPB (30 $μg/cm^2$ on the photosensor window and 40 $μg/cm^2$ on the detector wall), the light yield was 12.8 $\pm$ 0.3 p.e./keVee using PMTs with a quantum efficiency of approximately 30% for TPB-converted light. We also tested the low-temperature tolerance of TSV-MPPC, which has a high photon-detection efficiency, in the LAr environment. The TSV-MPPC detected the LAr scintillations converted by TPB with a photon-detection efficiency exceeding 50%.

physics.ins-det↗

Measurement of ambient neutrons in an underground laboratory at Kamioka Observatory and future plan

Ambient neutrons are one of the most serious backgrounds for underground experiments in search of rare events. The ambient neutron flux in an underground laboratory of Kamioka Observatory was measured using a $\mathrm{^3He}$ proportional counter with various moderator setups. Since the detector response largely depends on the spectral shape, the energy spectra of the neutrons transported from the rock to the laboratory were estimated by Monte-Carlo simulations. The ratio of the thermal neutron flux to the total neutron flux was found to depend on the thermalizing efficiency of the rock. Thus, the ratio of the count rate without a moderator to that with a moderator was used to determine this parameter. Consequently, the most-likely neutron spectrum predicted by the simulations for the parameters determined by the experimental results was obtained. The result suggests an interesting spectral shape, which has not been indicated in previous studies. The total ambient neutron flux is $(23.5 \pm 0.7 \ \mathrm{_{stat.}} ^{+1.9}_{-2.1} \ \mathrm{_{sys.}}) \times 10^{-6}$ cm$^{-2}$ s$^{-1}$. In this paper, we explain our method of the result and discuss our future plan.

physics.ins-det↗

Measurement of ambient neutrons in an underground laboratory at Kamioka Observatory

Ambient neutrons are one of the most serious backgrounds for underground experiments searching for rare events. The ambient neutron flux in an underground laboratory of Kamioka Observatory was measured using a $\mathrm{^3He}$ proportional counter with various moderator setups. Since the detector response largely depends on the spectral shape, the energy spectra of the neutrons transported from the rock to the laboratory are estimated by Monte-Carlo simulations. The ratio of the thermal neutron flux to the total neutron flux was found to depend on the thermalizing efficiency of the rock. Therefore, the ratio of the count rate without a moderator to that with a moderator was used to determine this parameter. Consequently, the most-likely neutron spectrum predicted by the simulations for the parameters determined by the experimental results was obtained. The result suggests an interesting spectral shape, which has not been indicated in previous studies. The total ambient neutron flux is $(23.52 \pm 0.68 \ \mathrm{_{stat.}} ^{+1.87}_{-2.13} \ \mathrm{_{sys.}}) \times 10^{-6}$ cm$^{-2}$ s$^{-1}$. This result, especially the energy spectrum information, could be a new and important input for estimating the background in current and future experiments in the underground laboratory at Kamioka Observatory.

physics.ins-det↗

ATCA-based ATLAS FTK input interface system

The first stage of the ATLAS Fast TracKer (FTK) is an ATCA-based input interface system, where hits from the entire silicon tracker are clustered and organized into overlapping eta-phi trigger towers before being sent to the tracking engines. First, FTK Input Mezzanine cards receive hit data and perform clustering to reduce data volume. Then, the ATCA-based Data Formatter system will organize the trigger tower data, sharing data among boards over full mesh backplanes and optic fibers. The board and system level design concepts and implementation details, as well as the operation experiences from the FTK full-chain testing, will be presented.

physics.ins-det↗