Searcharxiv⌕ Search

arXiv subjects

Koichiro Shimomura

Publications and source records attributed to Koichiro Shimomura.

6 recordsLinked to original sources

Hit-rate capability of a silicon strip detector module for decay positron detection in the J-PARC muon $g-2$/EDM experiment

In the J-PARC muon $g-2$/EDM experiment, a silicon strip detector will be used to detect positrons from muon decays. The detector consists of planes of detector modules arranged radially. The expected maximum hit rate reaches 1.4~MHz per sensor strip, and achieving high detection efficiency even under such hit-rate conditions is a key performance requirement. We have developed the smallest unit of the detector module, and its performance was evaluated using a muon beam at the J-PARC MLF H-line. The specifications of the detector module and the evaluated hit-rate capability are described in this article.

physics.ins-det↗

Recent application studies of an INTPIX4NA SOIPIX detector-based X-ray camera using an SiTCP-XG 10GbE-based high-speed readout system at KEK facilities

The Silicon-On-Insulator PIXel (SOIPIX) detector is a unique monolithic structure imaging device currently being developed by the SOIPIX group, led by the High Energy Accelerator Research Organization (KEK). Our detector team at the KEK Photon Factory (PF) has developed an X-ray camera based on the INTPIX4NA SOIPIX detector. This detector provides a sensitive area of 14.1 $\times$ 8.7 $\mathrm{mm^2}$, with 425,984 pixels arranged in an 832-column $\times$ 512-row matrix and a pixel size of 17 $\times$ 17 $\mathrm{μm^{2}}$, and offers high spatial resolution and excellent sensitivity under low-intensity X-ray conditions. The readout system used in the X-ray camera is developed at the PF. It is equipped with SiTCP-XG, a 10 Gb Ethernet network controller implemented on a field-programmable gate array, enabling high-frame-rate imaging at several hundred hertz. We are currently investigating the applicability of this X-ray camera in several experiments at KEK. Herein, we report three recent application studies: (1) X-ray zooming microscope optics using two Fresnel zone plates at PF AR-NE1A; (2) phase-contrast X-ray imaging system using a two-crystal X-ray interferometer at PF BL-14C; and (3) nondestructive lithium detection in Li-ion battery electrode materials using muonic X-rays at J-PARC MLF Muon D2.

physics.ins-det↗

Precision measurements of muonium and muonic helium hyperfine structure at J-PARC

At the J-PARC Muon Science Facility (MUSE), the MuSEUM collaboration is now performing new precision measurements of the ground state hyperfine structure (HFS) of both muonium and muonic helium atoms. High-precision measurements of the muonium ground-state HFS are recognized as one of the most sensitive tools for testing bound-state quantum electrodynamics theory to precisely probe the standard model and determine fundamental constants of the positive muon magnetic moment and mass. The same technique can also be employed to measure muonic helium HFS, obtain the negative muon magnetic moment and mass, and test and improve the theory of the three-body atomic system. Measurements at zero magnetic field have already yielded more accurate results than previous experiments for both muonium and muonic helium atoms. High-field measurements are now ready to start collecting data using the world's most intense pulsed muon beam at the MUSE H-line. We aim to improve the precision of previous measurements ten times for muonium and a hundred times or more for muonic helium. We review all the key developments for these new measurements, focusing on the high-field experiment, and report the latest results and prospects.

physics.atom-ph↗

Muon spin relaxation in mixed perovskite (LaAlO$_3$)$_{x}$(SrAl$_{0.5}$Ta$_{0.5}$O$_3$)$_{1-x}$ with $x\simeq 0.3$

We report on muon spin relaxation ($μ^+$SR) measurements in a mixed perovskite compound, (LaAlO$_3$)$_{x}$(SrAl$_{0.5}$Ta$_{0.5}$O$_3$)$_{1-x}$ with $x\simeq 0.3$ (LSAT), which is widely used as a single-crystalline substrate for thin film deposition. In zero applied field (ZF), muon depolarization due to the distribution of nuclear dipole fields was observed in the temperature range from 4 K to 270 K. Interestingly, $μ^+$SR time spectra in ZF maintained a Gaussian-like feature over the entire range, while the depolarization rate exhibited a monotonic decrease with increasing temperature. This behavior may be attributed to the thermally activated diffusion of muons between a few adjacent sites within a confined space of the angstrom scale, where the motionally averaged local field that each muon experiences can remain non-zero and result in maintaining the Gaussian-like line shape. The spatial distribution of electrostatic potential at lattice interstices evaluated via density functional theory calculations suggests that such a restriction of muon diffusion paths can be caused by the random distribution of cations with different nominal valences in the mixed perovskite lattice.

cond-mat.mtrl-sci↗

Negatively Charged Muonium and Related Centers in Solids

Muonium (Mu) centers formed upon implantation of $μ^+$ in a solid have long been investigated as an experimentally accessible model of isolated hydrogen impurities. Recent discoveries of hydridic centers formed at oxygen vacancies have stimulated a renewed interest in H$^-$ and corresponding Mu$^-$ centers in oxides. However, the two diamagnetic centers, Mu$^+$ and Mu$^-$, are difficult to separate spectroscopically. In this review article, we summarize established and developing methodologies for identifying Mu$^-$ centers in solids, and review recent Mu studies on said centers supposedly formed in mayenite, oxygen-deficient SrTiO$_{3-x}$, and BaTiO$_{3-x}$H$_x$ oxyhydride.

cond-mat.mtrl-sci↗

Hunting for T-violation and Majoranality of Neutrinos in Muon Decays

We propose a new experiment to search for a time-reversal (T) symmetry breaking process in muon decay and the Majoranality of the neutrinos. In the presence of V+A interactions, the Majoranality appears as a T-violating term in the muon decay width as shown by Doi et al, while in the Standard Model such a T-violating term is negligibly small. The presences of V+A interactions and the corresponding heavy right-handed Majorana neutrinos give us an important clue to solve two major issues in particle physics, the deficit of baryon asymmetry in the universe and the Majoranality of neutrinos. In the experiment, the polarization of positrons from muon decays is measured using a polarimeter consisting of a magnetized foil and a segmented calorimeter. According to our result of numerical calculation, a factor of ten improvement in sensitivity to the T-violating process is expected by a year of measurement at J-PARC Materials and Life Science Experimental Facility, compared to the most recent precursor experiment.

hep-ex↗