SearcharxivSearch

arXiv subjects

Konlin Shen

Publications and source records attributed to Konlin Shen.

3 recordsLinked to original sources

Miniscope3D: optimized single-shot miniature 3D fluorescence microscopy

Miniature fluorescence microscopes are a standard tool in systems biology. However, widefield miniature microscopes capture only 2D information, and modifications that enable 3D capabilities increase the size and weight and have poor resolution outside a narrow depth range. Here, we achieve the 3D capability by replacing the tube lens of a conventional 2D Miniscope with an optimized multifocal phase mask at the objective's aperture stop. Placing the phase mask at the aperture stop significantly reduces the size of the device, and varying the focal lengths enables a uniform resolution across a wide depth range. The phase mask encodes the 3D fluorescence intensity into a single 2D measurement, and the 3D volume is recovered by solving a sparsity-constrained inverse problem. We provide methods for designing and fabricating the phase mask and an efficient forward model that accounts for the field-varying aberrations in miniature objectives. We demonstrate a prototype that is 17 mm tall and weighs 2.5 grams, achieving 2.76 $μ$m lateral, and 15 $μ$m axial resolution across most of the 900x700x390 $μm^3$ volume at 40 volumes per second. The performance is validated experimentally on resolution targets, dynamic biological samples, and mouse brain tissue. Compared with existing miniature single-shot volume-capture implementations, our system is smaller and lighter and achieves a more than 2x better lateral and axial resolution throughout a 10x larger usable depth range. Our microscope design provides single-shot 3D imaging for applications where a compact platform matters, such as volumetric neural imaging in freely moving animals and 3D motion studies of dynamic samples in incubators and lab-on-a-chip devices.

eess.IV

StimDust: A mm-scale implantable wireless precision neural stimulator with ultrasonic power and communication

Neural stimulation is a powerful technique for modulating physiological functions and for writing information into the nervous system as part of brain-machine interfaces. Current clinically approved neural stimulators require batteries and are many cubic centimetres in size -- typically much larger than their intended targets. We present a complete wireless neural stimulation system consisting of a 1.7 mm3 wireless, batteryless, leadless implantable stimulator (the "mote"), an ultrasonic wireless link for power and bi-directional communication, and a hand-held external transceiver. The mote consists of a piezoceramic transducer, an energy storage capacitor, and a stimulator integrated circuit (IC). The IC harvests ultrasonic power with high efficiency, decodes stimulation parameter downlink data, and generates current-controlled stimulation pulses. Stimulation parameters are time-encoded on the fly through the wireless link rather than being programmed and stored on the mote, reducing power consumption and on-chip memory requirements and enabling complex stimulation protocols with high-temporal resolution and low-latency feedback for use in closed-loop stimulation. Uplink data indicates whether the mote is currently stimulating; it is encoded by the mote via backscatter modulation and is demodulated at the external transceiver. We show that the mote operates at an acoustic intensity that is 7.8% of the FDA limit for diagnostic ultrasound and characterize the acoustic wireless link's robustness to expected real-world misalignment. We demonstrate the in vivo performance of the system with motes acutely implanted with a cuff on the sciatic nerve of anesthetized rats and show highly repeatable stimulation across a wide range of physiological responses.

q-bio.NC

A Sub-mm$^3$ Ultrasonic Free-floating Implant for Multi-mote Neural Recording

A 0.8 mm$^3$ wireless, ultrasonically powered, free-floating neural recording implant is presented. The device is comprised only of a 0.25 mm$^2$ recording IC and a single piezoceramic resonator that is used for both power harvesting and data transmission. Uplink data transmission is performed by analog amplitude modulation of the ultrasound echo. Using a 1.78 MHz main carrier, >35 kbps/mote equivalent uplink data rate is achieved. A technique to linearize the echo amplitude modulation is introduced, resulting in <1.2\% static nonlinearity of the received signal over a $\pm$10 mV input range. The IC dissipates 37.7 $μ$W, while the neural recording front-end consumes 4 $μ$W and achieves a noise floor of 5.3 $μ$V$_{rms}$ in a 5 kHz bandwidth. This work improves sub-mm recording mote depth by >2.5x, resulting in the highest measured depth/volume ratio by $\sim$3x. Orthogonal subcarrier modulation enables simultaneous operation of multiple implants, using a single-element ultrasound external transducer. Dual-mote simultaneous power up and data transmission is demonstrated at a rate of 7 kS/s at the depth of 50 mm.

eess.SP