SearcharxivSearch

arXiv subjects

Konstantin Nikolaou

Publications and source records attributed to Konstantin Nikolaou.

15 recordsLinked to original sources

Towards Sustainable Magnetic Resonance Imaging: Insights from long-term, high-resolution energy recordings across an entire scanner fleet

Magnetic resonance imaging (MRI) is among the most energy-intensive diagnostic modalities in healthcare, yet its energy consumption and the factors influencing it remain insufficiently understood. This study aims to establish a comprehensive baseline of MRI energy consumption by characterizing energy demand across a scanner fleet, examining scanner utilization and operating patterns in clinical practice. Concurrently, it investigates the relationships between energy consumption and relevant operational and acquisition features. On average, a single MRI measurement consumed 0.43 kWh, while a complete examination consumed 13.50 kWh. In general, substantial differences in energy consumption were observed between MRI scanners and their corresponding operating modes (scan, idle, and eco-power mode). These variations may be related to differences in scanner operating patterns, employed examination protocols, and their resulting acquisition parameters. Idle and eco-power modes accounted for more cumulative energy consumption than active scanning. However, these energy shares should always be interpreted in relation to scanner occupancy, as utilization patterns strongly influence the distribution of energy across those operating modes. Lastly, linear regression analysis showed that energy consumption was more strongly associated with scan duration than with average power, suggesting that scan duration may be an important factor influencing MRI energy consumption. ...

physics.med-ph

Sustainable MRI: Interpretable Deep Learning for estimating energy and power consumption, revealing key acquisition parameters and their interactions

Magnetic resonance imaging (MRI) is among the most energy-intensive medical imaging modalities. To facilitate the development of more energy-efficient MRI protocols and sequences, we developed an interpretable data-driven deep learning (DL) framework to characterize the factors driving energy and power consumption. The aim was to identify the most influential acquisition parameters and their interactions on MRI energy and power demand, and to prospectively predict energy and power consumption on a per-sequence level. Two separate DL models were trained to predict energy and power consumption from MRI acquisition parameters. Attention weights were analyzed to identify the most influential parameters and their interactions. The proposed DL models successfully captured the variability in the data (energy model: $R^2 = 0.963$, power model: $R^2 = 0.843$). Energy was primarily driven by temporal parameters, whereas power depended on more complex sequence, gradient, and RF-related interactions. These results demonstrate that energy and power consumption can be accurately predicted from MRI acquisition parameters alone. The proposed framework reveals that a small subset of parameters governs energy and power demand, providing interpretable insights to support the development of more energy-efficient scanning protocols and sequences.

eess.IV

Spectral Reach: Understanding Neural Scaling as Progress into the Spectral Tail

Neural scaling laws describe predictable power-law relationships between model size, dataset size, compute, and performance. While these laws guide the development of modern foundation models, the mechanisms underpinning them remain poorly understood, in part due to the absence of scalable analysis tools. To close this gap, we introduce "spectral position": a scalable measure of which eigenvalues of the empirical neural tangent kernel (eNTK) currently drive loss reduction. Applying this measure to scaling experiments, we find that spectral position decreases throughout training: learning shifts from dominant eigenmodes into the spectral tail. Larger models reach further into the tail than smaller models, revealing a size-dependent capacity we call "spectral reach". This suggests why larger models achieve lower losses: they sustain learning on weak spectral signals inaccessible to smaller models. We further identify feature learning as a key enabler of spectral reach. It adaptively amplifies gradient magnitudes as learning advances, sustaining progress where frozen representations stall. This points to concrete interventions through architecture and optimizer design.

cs.LG

Reinforcement Learning Enables Autonomous Microrobot Navigation and Intervention in Simulated Blood Capillaries

Autonomous microrobots navigating biological vasculature could enable targeted drug delivery and thrombolysis, yet training control policies for realistic environments remains an open challenge. Prior reinforcement learning (RL) studies of microrobotic navigation have been limited to idealized geometries that omit complex hydrodynamic flow fields, confined branching structures, and dense cellular obstacles found in vivo. Here, we develop a physically grounded simulation of a blood capillary network, incorporating realistic hydrodynamic flow fields, explicit red blood cell dynamics, and anatomically derived branching geometry, and train deep RL agents to navigate it via chemotaxis. We systematically map the physical limits of navigation across robot size and swimming speed, revealing a forbidden regime where Brownian motion and flow overcome propulsion. Successful agents independently discover multiple universal strategy types, including run-and-rotate and energy-efficient search-and-sit policies, regardless of robot parameters. Without retraining, these agents perform targeted blocking and unblocking of capillary flow, restoring throughput to healthy baseline levels. These results establish RL as a viable framework for developing autonomous microrobotic intervention strategies in complex biological environments.

cs.RO

The autoPET3 Challenge: Automated Lesion Segmentation in Whole-Body PET/CT $\unicode{x2013}$ Multitracer Multicenter Generalization

We report the design and results of the third autoPET challenge (MICCAI 2024), which benchmarked automated lesion segmentation in whole-body PET/CT under a compositional generalization setting. Training data comprised 1,014 [18F]-FDG PET/CT studies from the University Hospital Tübingen and 597 [18F]/[68Ga]-PSMA PET/CT studies from the LMU University Hospital Munich, constituting the largest publicly available annotated PSMA PET/CT dataset to date. The held-out test set of 200 studies covered four tracer-center combinations, two of which represented unseen compositional pairings. A complementary data-centric award category isolated the contribution of data handling strategies by restricting participants to a fixed baseline model. Seventeen teams submitted 27 algorithms, predominantly nnU-Net-based 3D networks with PET/CT channel concatenation. The top-ranked algorithm achieved a mean DSC of 0.66, FNV of 3.18 mL, and FPV of 2.78 mL across all four test conditions, improving DSC by 8% and reducing the false-negative volume by 5 mL relative to the provided baseline. Ranking was stable across bootstrap resampling and alternative ranking schemes for the top tier. Beyond the benchmark, we provide an in-depth analysis of segmentation performance at the patient and lesion level. Three main conclusions can be drawn: (1) in-domain multitracer PET/CT segmentation is sufficient and probably approaching reader agreement; (2) compositional generalization to unseen tracer-center combinations remains an open problem mainly driven by systematic volume overestimation; (3) heterogeneity and case difficulty drive performance variation substantially more than the choice of algorithm among top-ranked teams.

cs.CV

Beyond Scaling Curves: Internal Dynamics of Neural Networks Through the NTK Lens

Scaling laws offer valuable insights into the relationship between neural network performance and computational cost, yet their underlying mechanisms remain poorly understood. In this work, we empirically analyze how neural networks behave under data and model scaling through the lens of the neural tangent kernel (NTK). This analysis establishes a link between performance scaling and the internal dynamics of neural networks. Our findings of standard vision tasks show that similar performance scaling exponents can occur even though the internal model dynamics show opposite behavior. This demonstrates that performance scaling alone is insufficient for understanding the underlying mechanisms of neural networks. We also address a previously unresolved issue in neural scaling: how convergence to the infinite-width limit affects scaling behavior in finite-width models. To this end, we investigate how feature learning is lost as the model width increases and quantify the transition between kernel-driven and feature-driven scaling regimes. We identify the maximum model width that supports feature learning, which, in our setups, we find to be more than ten times smaller than typical large language model widths.

cs.LG

Requirements for Quality Assurance of AI Models for Early Detection of Lung Cancer

Lung cancer is the second most common cancer and the leading cause of cancer-related deaths worldwide. Survival largely depends on tumor stage at diagnosis, and early detection with low-dose CT can significantly reduce mortality in high-risk patients. AI can improve the detection, measurement, and characterization of pulmonary nodules while reducing assessment time. However, the training data, functionality, and performance of available AI systems vary considerably, complicating software selection and regulatory evaluation. Manufacturers must specify intended use and provide test statistics, but they can choose their training and test data, limiting standardization and comparability. Under the EU AI Act, consistent quality assurance is required for AI-based nodule detection, measurement, and characterization. This position paper proposes systematic quality assurance grounded in a validated reference dataset, including real screening cases plus phantom data to verify volume and growth rate measurements. Regular updates shall reflect demographic shifts and technological advances, ensuring ongoing relevance. Consequently, ongoing AI quality assurance is vital. Regulatory challenges are also adressed. While the MDR and the EU AI Act set baseline requirements, they do not adequately address self-learning algorithms or their updates. A standardized, transparent quality assessment - based on sensitivity, specificity, and volumetric accuracy - enables an objective evaluation of each AI solution's strengths and weaknesses. Establishing clear testing criteria and systematically using updated reference data lay the groundwork for comparable performance metrics, informing tenders, guidelines, and recommendations.

cs.CY

Collective variables of neural networks: empirical time evolution and scaling laws

This work presents a novel means for understanding learning dynamics and scaling relations in neural networks. We show that certain measures on the spectrum of the empirical neural tangent kernel, specifically entropy and trace, yield insight into the representations learned by a neural network and how these can be improved through architecture scaling. These results are demonstrated first on test cases before being shown on more complex networks, including transformers, auto-encoders, graph neural networks, and reinforcement learning studies. In testing on a wide range of architectures, we highlight the universal nature of training dynamics and further discuss how it can be used to understand the mechanisms behind learning in neural networks. We identify two such dominant mechanisms present throughout machine learning training. The first, information compression, is seen through a reduction in the entropy of the NTK spectrum during training, and occurs predominantly in small neural networks. The second, coined structure formation, is seen through an increasing entropy and thus, the creation of structure in the neural network representations beyond the prior established by the network at initialization. Due to the ubiquity of the latter in deep neural network architectures and its flexibility in the creation of feature-rich representations, we argue that this form of evolution of the network's entropy be considered the onset of a deep learning regime.

cs.LG

SwarmRL: Building the Future of Smart Active Systems

This work introduces SwarmRL, a Python package designed to study intelligent active particles. SwarmRL provides an easy-to-use interface for developing models to control microscopic colloids using classical control and deep reinforcement learning approaches. These models may be deployed in simulations or real-world environments under a common framework. We explain the structure of the software and its key features and demonstrate how it can be used to accelerate research. With SwarmRL, we aim to streamline research into micro-robotic control while bridging the gap between experimental and simulation-driven sciences. SwarmRL is available open-source on GitHub at https://github.com/SwarmRL/SwarmRL.

cs.RO

Towards a Phenomenological Understanding of Neural Networks: Data

A theory of neural networks (NNs) built upon collective variables would provide scientists with the tools to better understand the learning process at every stage. In this work, we introduce two such variables, the entropy and the trace of the empirical neural tangent kernel (NTK) built on the training data passed to the model. We empirically analyze the NN performance in the context of these variables and find that there exists correlation between the starting entropy, the trace of the NTK, and the generalization of the model computed after training is complete. This framework is then applied to the problem of optimal data selection for the training of NNs. To this end, random network distillation (RND) is used as a means of selecting training data which is then compared with random selection of data. It is shown that not only does RND select data-sets capable of outperforming random selection, but that the collective variables associated with the RND data-sets are larger than those of the randomly selected sets. The results of this investigation provide a stable ground from which the selection of data for NN training can be driven by this phenomenological framework.

cs.LG

Characterization of harmonic modes and parasitic resonances in multi-mode superconducting coplanar resonators

Planar superconducting microwave transmission line resonators can be operated at multiple harmonic resonance frequencies. This allows covering wide spectral regimes with high sensitivity, as it is desired e.g. for cryogenic microwave spectroscopy. A common complication of such experiments is the presence of undesired 'spurious' additional resonances, which are due to standing waves within the resonator substrate or housing box. Identifying the nature of individual resonances ('designed' vs. 'spurious') can become challenging for higher frequencies or if elements with unknown material properties are included, as is common for microwave spectroscopy. Here we discuss various experimental strategies to distinguish designed and spurious modes in coplanar superconducting resonators that are operated in a broad frequency range up to 20 GHz. These strategies include tracking resonance evolution as a function of temperature, magnetic field, and microwave power. We also demonstrate that local modification of the resonator, by applying minute amounts of dielectric or ESR-active materials, lead to characteristic signatures in the various resonance modes, depending on the local strength of the electric or magnetic microwave fields.

cond-mat.supr-con

Fully Automated and Standardized Segmentation of Adipose Tissue Compartments by Deep Learning in Three-dimensional Whole-body MRI of Epidemiological Cohort Studies

Purpose: To enable fast and reliable assessment of subcutaneous and visceral adipose tissue compartments derived from whole-body MRI. Methods: Quantification and localization of different adipose tissue compartments from whole-body MR images is of high interest to examine metabolic conditions. For correct identification and phenotyping of individuals at increased risk for metabolic diseases, a reliable automatic segmentation of adipose tissue into subcutaneous and visceral adipose tissue is required. In this work we propose a 3D convolutional neural network (DCNet) to provide a robust and objective segmentation. In this retrospective study, we collected 1000 cases (66$\pm$ 13 years; 523 women) from the Tuebingen Family Study and from the German Center for Diabetes research (TUEF/DZD), as well as 300 cases (53$\pm$ 11 years; 152 women) from the German National Cohort (NAKO) database for model training, validation, and testing with a transfer learning between the cohorts. These datasets had variable imaging sequences, imaging contrasts, receiver coil arrangements, scanners and imaging field strengths. The proposed DCNet was compared against a comparable 3D UNet segmentation in terms of sensitivity, specificity, precision, accuracy, and Dice overlap. Results: Fast (5-7seconds) and reliable adipose tissue segmentation can be obtained with high Dice overlap (0.94), sensitivity (96.6%), specificity (95.1%), precision (92.1%) and accuracy (98.4%) from 3D whole-body MR datasets (field of view coverage 450x450x2000mm${}^3$). Segmentation masks and adipose tissue profiles are automatically reported back to the referring physician. Conclusion: Automatic adipose tissue segmentation is feasible in 3D whole-body MR data sets and is generalizable to different epidemiological cohort studies with the proposed DCNet.

cs.CV

MedGAN: Medical Image Translation using GANs

Image-to-image translation is considered a new frontier in the field of medical image analysis, with numerous potential applications. However, a large portion of recent approaches offers individualized solutions based on specialized task-specific architectures or require refinement through non-end-to-end training. In this paper, we propose a new framework, named MedGAN, for medical image-to-image translation which operates on the image level in an end-to-end manner. MedGAN builds upon recent advances in the field of generative adversarial networks (GANs) by merging the adversarial framework with a new combination of non-adversarial losses. We utilize a discriminator network as a trainable feature extractor which penalizes the discrepancy between the translated medical images and the desired modalities. Moreover, style-transfer losses are utilized to match the textures and fine-structures of the desired target images to the translated images. Additionally, we present a new generator architecture, titled CasNet, which enhances the sharpness of the translated medical outputs through progressive refinement via encoder-decoder pairs. Without any application-specific modifications, we apply MedGAN on three different tasks: PET-CT translation, correction of MR motion artefacts and PET image denoising. Perceptual analysis by radiologists and quantitative evaluations illustrate that the MedGAN outperforms other existing translation approaches.

cs.CV

Retrospective correction of Rigid and Non-Rigid MR motion artifacts using GANs

Motion artifacts are a primary source of magnetic resonance (MR) image quality deterioration with strong repercussions on diagnostic performance. Currently, MR motion correction is carried out either prospectively, with the help of motion tracking systems, or retrospectively by mainly utilizing computationally expensive iterative algorithms. In this paper, we utilize a new adversarial framework, titled MedGAN, for the joint retrospective correction of rigid and non-rigid motion artifacts in different body regions and without the need for a reference image. MedGAN utilizes a unique combination of non-adversarial losses and a new generator architecture to capture the textures and fine-detailed structures of the desired artifact-free MR images. Quantitative and qualitative comparisons with other adversarial techniques have illustrated the proposed model performance.

cs.CV

A Machine-learning framework for automatic reference-free quality assessment in MRI

Magnetic resonance (MR) imaging offers a wide variety of imaging techniques. A large amount of data is created per examination which needs to be checked for sufficient quality in order to derive a meaningful diagnosis. This is a manual process and therefore time- and cost-intensive. Any imaging artifacts originating from scanner hardware, signal processing or induced by the patient may reduce the image quality and complicate the diagnosis or any image post-processing. Therefore, the assessment or the ensurance of sufficient image quality in an automated manner is of high interest. Usually no reference image is available or difficult to define. Therefore, classical reference-based approaches are not applicable. Model observers mimicking the human observers (HO) can assist in this task. Thus, we propose a new machine-learning-based reference-free MR image quality assessment framework which is trained on HO-derived labels to assess MR image quality immediately after each acquisition. We include the concept of active learning and present an efficient blinded reading platform to reduce the effort in the HO labeling procedure. Derived image features and the applied classifiers (support-vector-machine, deep neural network) are investigated for a cohort of 250 patients. The MR image quality assessment framework can achieve a high test accuracy of 93.7$\%$ for estimating quality classes on a 5-point Likert-scale. The proposed MR image quality assessment framework is able to provide an accurate and efficient quality estimation which can be used as a prospective quality assurance including automatic acquisition adaptation or guided MR scanner operation, and/or as a retrospective quality assessment including support of diagnostic decisions or quality control in cohort studies.

cs.CV