Searcharxiv⌕ Search

arXiv subjects

Kun Liang

Publications and source records attributed to Kun Liang.

22 records · Page 2Linked to original sources

Dynamic adaptive procedures that control the false discovery rate

In the multiple testing problem with independent tests, the classical linear step-up procedure controls the false discovery rate (FDR) at level $π_0α$, where $π_0$ is the proportion of true null hypotheses and $α$ is the target FDR level. Adaptive procedures can improve power by incorporating estimates of $π_0$, which typically rely on a tuning parameter. Fixed adaptive procedures set their tuning parameters before seeing the data and can be shown to control the FDR in finite samples. We develop theoretical results for dynamic adaptive procedures whose tuning parameters are determined by the data. We show that, if the tuning parameter is chosen according to a left-to-right stopping time rule, the corresponding dynamic adaptive procedure controls the FDR in finite samples. Examples include the recently proposed right-boundary procedure and the widely used lowest-slope procedure, among others. Simulation results show that the right-boundary procedure is more powerful than other dynamic adaptive procedures under independence and mild dependence conditions.

stat.ME↗

An Improved Evaluation of the Neutron Background in the PandaX-II Experiment

In dark matter direct detection experiments, neutron is a serious source of background, which can mimic the dark matter-nucleus scattering signals. In this paper, we present an improved evaluation of the neutron background in the PandaX-II dark matter experiment by a novel approach. Instead of fully relying on the Monte Carlo simulation, the overall neutron background is determined from the neutron-induced high energy signals in the data. In addition, the probability of producing a dark-matter-like background per neutron is evaluated with a complete Monte Carlo generator, where the correlated emission of neutron(s) and $γ$(s) in the ($α$, n) reactions and spontaneous fissions is taken into consideration. With this method, the neutron backgrounds in the Run 9 (26-ton-day) and Run 10 (28-ton-day) data sets of PandaX-II are estimated to be 0.66$\pm$0.24 and 0.47$\pm$0.25 events, respectively.

hep-ex↗

Searching for Neutrino-less Double Beta Decay of $^{136}$Xe with PandaX-II Liquid Xenon Detector

We report the Neutrino-less Double Beta Decay (NLDBD) search results from PandaX-II dual-phase liquid xenon time projection chamber. The total live time used in this analysis is 403.1 days from June 2016 to August 2018. With NLDBD-optimized event selection criteria, we obtain a fiducial mass of 219 kg of natural xenon. The accumulated xenon exposure is 242 kg$\cdot$yr, or equivalently 22.2 kg$\cdot$yr of $^{136}$Xe exposure. At the region around $^{136}$Xe decay Q-value of 2458 keV, the energy resolution of PandaX-II is 4.2%. We find no evidence of NLDBD in PandaX-II and establish a lower limit for decay half-life of 2.4 $ \times 10^{23} $ yr at the 90% confidence level, which corresponds to an effective Majorana neutrino mass $m_{ββ} < (1.3 - 3.5)$ eV. This is the first NLDBD result reported from a dual-phase xenon experiment.

hep-ex↗

Rayleigh-Brillouin scattering in SF$_6$ in the kinetic regime

Rayleigh-Brillouin spectral profiles are measured with a laser-based scatterometry setup for a 90 degrees scattering angle at a high signal-to-noise ratio (r.m.s. noise below 0.15 \% w.r.t. peak intensity) in sulphur-hexafluoride gas for pressures in the range 0.2 -- 5 bar and for a wavelength of $λ=403.0$ nm. The high quality data are compared to a number of light scattering models in order to address the effects of rotational and vibrational relaxation. While the vibrational relaxation rate is so slow that vibration degrees of freedom remain frozen, rotations relax on time scales comparable to those of the density fluctuations. Therefore, the heat capacity, the thermal conductivity and the bulk viscosity are all frequency-dependent transport coefficients. This is relevant for the Tenti model that depends on the values chosen for these transport coefficients. This is not the case for the other two models considered: a kinetic model based on rough-sphere interactions, and a model based on fluctuating hydrodynamics. The deviations with the experiment are similar between the three different models, except for the hydrodynamic model at pressures $p \lesssim 2\;{\rm bar}$. As all models are in line with the ideal gas law, we hypothesize the presence of real gas effects in the measured spectra.

physics.flu-dyn↗