Searcharxiv⌕ Search

arXiv subjects

Kushul Reddy Palakala

Publications and source records attributed to Kushul Reddy Palakala.

2 recordsLinked to original sources

ModaLens: Measuring Image Sensitivity in Report-Conditioned Medical VLMs

A radiology report can already answer a clinical question, so it is hard to tell whether a vision-language model also uses the image. ModaLens, a paired image-swap audit, measures how report availability changes image sensitivity: MedGemma-27B on 3,199 paired MIMIC-CXR cases from 293 patients, all 14 questions per case (13 finding-specific and one composite), each image replaced by one from another study, usually of the same patient, with question and report fixed. Under an explicit answer instruction, the model's generated answer changes on 4.26 percent of trials with the report and 20.94 percent without it, a paired increase of 16.7 points (patient-clustered 95 percent CI 15.6 to 17.7), so report availability reduces image-swap sensitivity under this protocol; the original prompt with a lowercase first-token readout gives 4.70 percent against 17.07 percent, and substitutions also move continuous answer scores where the binary prediction does not change. The labels are derived from reports, which limits conclusions about visual correctness; the direction replicates in two further model lineages. Code, the exact prompts and a run record for every number are at https://github.com/criticaldata/MODALENS.

cs.CV↗

Loud or Silent? A Reusable Framework for Per-Modality Failure Analysis in Multimodal Clinical AI

Multimodal clinical models are usually judged on accuracy with every modality present, but deployment removes modalities; an echocardiogram is often unavailable where an ECG is routine. Two questions then matter beyond the size of the accuracy loss: which modality was responsible, and whether the model fails loudly or silently once that modality is dropped. The distinction is per-example and modality-level, and is separate from post-hoc feature attribution (e.g. SHAP). Models are replaced often; the evaluation that answers these questions is reused. We present a model-agnostic modality-failure framework: given N modality embeddings, any mask-aware probe, and labels, it returns a per-example failure taxonomy, a per-modality complementarity matrix that attributes error to modalities, and a loud-vs-silent dropout profile separating monitorable failures from those that pass unflagged far from the decision boundary, using only deployment-observable signals. We release it as a small, unit-tested harness and validate it against planted ground truth. Across seeds it recovers that planted modality dominance and complementary subset, reports per-modality loud-vs-silent rates, and scales to a three-modality complementarity matrix; because the planted structure is known by construction, this validates recovery of per-example attribution rather than clinical performance. We then instantiate the framework on frozen EchoJEPA and HuBERT-ECG embeddings for LVEF and the EF <= 40% HFrEF gate over a paired MIMIC-IV cohort, where on the held-out test split (n = 245) dropping echo nearly doubles error. The narrow echo-to-ECG overlap that bounds cohort size is itself a deployment finding for cardiac foundation models. All of our work can be found at https://github.com/criticaldata/PRIMED-AI.

cs.AI↗