Searcharxiv⌕ Search

arXiv subjects

Kwangzoo Chung

Publications and source records attributed to Kwangzoo Chung.

3 recordsLinked to original sources

Quantum-walk transport oracles and amplitude estimation of a scalar range statistic in proton therapy

Quantum amplitude estimation (QAE) promises a quadratic reduction in the sampling cost of Monte Carlo (MC) particle transport, but two obstacles have kept it from radiotherapy physics: the lack of an efficient unitary encoding of charged-particle transport, and the mismatch between QAE's single-scalar output and the per-voxel structure of dose calculation. We address both. We construct a discrete-time quantum-walk transport oracle for protons in which an energy register is driven by an energy-dependent coin encoding a continuous-slowing-down surrogate of the stopping power, so that stochastic energy loss and range straggling follow from the circuit dynamics. The oracle is unitary, with one fresh coin qubit per step, and its gate count grows linearly in the number of energy levels. On it we formulate a scalar range statistic, the probability that a proton penetrates beyond a distal depth threshold, as a directly marked amplitude, and estimate it by maximum-likelihood amplitude estimation (MLQAE) with Grover iterations and finite shots. The oracle reproduces a Bragg-shaped depth-deposit profile agreeing with a classical MC of identical rules to within 0.27%, and Grover amplification matches $\sin^2((2k+1)θ)$ to machine precision up to $k=32$. At matched budget the MLQAE error falls as $N^{-0.93}$ against $N^{-0.49}$ for sampling, 4.8 times smaller at the largest budget. A three-gate resource analysis (output structure, amortization, error-corrected wall-clock) finds full dose maps structurally unfavourable irrespective of hardware, and the scalar statistic short of a wall-clock crossover at clinical scale: the oracle's derived cost of $1.0 \times 10^6$ logical gates per call ($3.5 \times 10^7$ with rotation synthesis), dominated by the multiplexed coin, is 160 to 5400 times the permitted budget. We report the reduction that would be required and identify the term responsible for it.

physics.med-ph↗

The Proton Therapy Nozzles at Samsung Medical Center: A Monte Carlo Simulation Study using TOPAS

To expedite the commissioning process of the proton therapy system at Samsung Medical Center (SMC), we have developed a Monte Carlo simulation model of the proton therapy nozzles using TOPAS. At SMC proton therapy center, we have two gantry rooms with different types of nozzles; a multi-purpose nozzle and a dedicated scanning nozzle. Each nozzle has been modeled in detail following the geometry information provided by the manufacturer, Sumitomo Heavy Industries, Ltd. For this purpose, novel features of TOPAS, such as the time feature or the ridge filter class, have been used. And the appropriate physics models for proton nozzle simulation were defined. Dosimetric properties, like percent depth dose curve, spread-out Bragg peak (SOBP), beam spot size, have been simulated and verified against measured beam data. Beyond the Monte Carlo nozzle modeling, we have developed an interface between TOPAS and the treatment planning system (TPS), RayStation. An exported RT plan data from the TPS has been interpreted by the interface and then translated into the TOPAS input text. The developed Monte Carlo nozzle model can be used to estimate non-beam performance of the nozzles such as the neutron background. Furthermore, the nozzle model can be used to study mechanical optimization in the design of the nozzle.

physics.med-ph↗

Feasibility Study of Neutron Dose for Real Time Image Guided Proton Therapy: A Monte Carlo Study

Two full rotating gantry with different nozzles (Multipurpose nozzle with MLC, Scanning Dedicated nozzle) with conventional cyclotron system is installed and under commissioning for various proton treatment options at Samsung Medical Center in Korea. The purpose of this study is to investigate neutron dose equivalent per therapeutic dose, H/D, to x-ray imaging equipment under various treatment conditions with monte carlo simulation. At first, we investigated H/D with the various modifications of the beam line devices (Scattering, Scanning, Multi-leaf collimator, Aperture, Compensator) at isocenter, 20, 40, 60 cm distance from isocenter and compared with other research groups. Next, we investigated the neutron dose at x-ray equipments used for real time imaging with various treatment conditions. Our investigation showed the 0.07 ~ 0.19 mSv/Gy at x-ray imaging equipments according to various treatment options and intestingly 50% neutron dose reduction effect of flat panel detector was observed due to multi- leaf collimator during proton scanning treatment with multipurpose nozzle. In future studies, we plan to investigate experimental measurement of neutron dose and validation of simulation data for x-ray imaging equipment with additional neutron dose reduction method.

physics.med-ph↗