SearcharxivSearch

arXiv subjects

Kwok-Shing Chan

Publications and source records attributed to Kwok-Shing Chan.

6 recordsLinked to original sources

Vendor-Agnostic Joint Relaxometry and Myelin Water Fraction Mapping with B1 and Motion Correction

Obtaining consistent quantitative maps of myelin content and relaxation times across different sites and vendors is essential for advancing our understanding of brain development. Herein, we present a harmonized, vendor-agnostic magnetic resonance acquisition method designed for joint T1, T2, and myelin water fraction mapping, along with a method for rapid B1+ and B1- field estimation. We used our dictionary-based fitting and multi-compartment modeling for joint mapping of T1, T2 and myelin water fraction. Self-navigation-based retrospective motion correction was integrated with subspace reconstruction to track and correct rigid head motion during scanning, operating without the need for external hardware. Simulations, phantom and in vivo experiments confirmed the sensitivity and accuracy of the method, particularly for short T2 values corresponding to myelin, and demonstrated consistent performance across multiple scanner types. Coupled with the harmonized calibration scan, the proposed package offers a practical tool for multi-site, multi-vendor neuroimaging studies in both adult and pediatric populations.

physics.med-ph

MWF-MIMOSA for efficient simultaneous relaxometry and myelin water fraction mapping

Quantitative magnetic resonance imaging (qMRI) provides improved sensitivity and specificity to tissue composition and pathological alterations compared with conventional contrast-weighted imaging. Among various qMRI biomarkers, myelin water imaging is of particular interest because myelin plays a central role in brain function and its alteration is closely associated with many neurological diseases. However, conventional myelin water fraction (MWF) mapping techniques are often limited by long scan times, low spatial resolution, reduced signal-to-noise ratio (SNR), and high specific absorption rate (SAR). Here, we propose MWF-MIMOSA for efficient simultaneous T1, T2, T2* mapping, magnetic susceptibility source separation, and MWF estimation. To achieve this, multi-contrast and multi-slice zero-shot self-supervised learning (MZS-SSL) was used to jointly reconstruct whole-brain complex-valued images. To improve computational efficiency of the parameter estimation step, a multilayer perceptron (MLP) was trained within the GACELLE GPU-accelerated parameter estimation framework to circumvent the computationally intensive Bloch simulation process, resulting in a >100-fold computational speed-up in MWF estimation. Numerical simulations were performed to evaluate the accuracy and precision of MWF-MIMOSA, and in-vivo results further demonstrated its robustness. Comparison with existing myelin water imaging methods showed that MWF-MIMOSA is highly correlated with established approaches, while providing complementary quantitative parameter maps at higher spatial resolution and with shorter scan times. Notably, simultaneous multi-parametric mapping was achieved in 5 min at 1 mm isotropic resolution, and in 10 min at 0.7 mm isotropic resolution. These results demonstrate the potential of MWF-MIMOSA for fast, high-resolution simultaneous relaxometry and myelin water imaging.

physics.med-ph

GACELLE: GPU-accelerated tools for model parameter estimation and image reconstruction

Quantitative MRI (qMRI) offers tissue-specific biomarkers that can be tracked over time or compared across populations; however, its adoption in clinical research is hindered by significant computational demands of parameter estimation. Images acquired at high spatial resolution or requiring fitting multiple parameters often require lengthy processing time, constraining their use in routine pipelines and slowing methodological innovation and clinical translation. We present GACELLE, an open source, GPU-accelerated framework for high-throughput qMRI analysis. GACELLE provides a stochastic gradient descent optimiser and a stochastic sampler in MATLAB, enabling fast parameter mapping, improved estimation robustness via spatial regularisation, and uncertainty quantification. GACELLE prioritises accessibility: users only need to provide a forward signal model, while GACELLE's backend manages computational parallelisation, automatic parameter updates, and memory-batching. The stochastic solver performs fully vectorised Markov chain Monte Carlo with identical likelihood on CPU and GPU, ensuring reproducibility across hardware. Benchmarking demonstrates up to 451-fold acceleration for the stochastic gradient descent solver and 14,380-fold acceleration for stochastic sampling compared to CPU-based estimation, without compromising accuracy. We demonstrated GACELLE's versatility on three representative qMRI models and on an image reconstruction task. Across these applications, GACELLE improves parameter precision, enhances test-retest reproducibility, and reduces noise in quantitative maps. By combining speed, usability and flexibility, GACELLE provides a generalisable optimisation framework for medical image analysis. It lowers the computational barrier for qMRI, paving the way for reproducible biomarker development, large-scale imaging studies, and clinical translation.

eess.IV

Reduced NEXI protocol for the quantification of human gray matter microstructure on the Connectome 2.0 scanner

Biophysical diffusion MRI models like Neurite Exchange Imaging (NEXI) are essential for probing gray matter microstructure, estimating compartment diffusivities, neurite fraction, and exchange time. However, NEXI's multi-shell, multi-diffusion-time requirements cause prohibitively long acquisitions. Leveraging the Connectome 2.0 ultra-high gradient scanner, we developed a time-efficient protocol using an Explainable AI (XAI) framework. Combining XGBoost, SHAP, and Recursive Feature Elimination trained on synthetic signals, XAI identified an optimal 8-feature subset, cutting scan time from 27 to 14 minutes. Validated in vivo in seven healthy participants, the XAI protocol was benchmarked against the full 15-feature acquisition, a Cram'er-Rao Lower Bound (CRLB) theoretical optimum, and two heuristics ("Mid-Range" and "Corner"). It robustly reproduced parameter estimates and maintained test-retest reproducibility. Remarkably, the XAI selection converged to the CRLB optimum. This validates XAI's optimality while highlighting its main advantage: achieving gold-standard optimization without complex analytical Jacobians, making it easily adaptable to numerical models or complex noise where CRLB is intractable. Furthermore, XAI showed superior in vivo robustness over heuristics: "Mid-Range" sampling yielded biased exchange time estimates from insufficient temporal diversity, while "Corner" sampling gave unstable intra-neurite diffusivity estimates (5-fold higher CV) due to noise sensitivity. Ultimately, this robust 14-minute protocol accelerates exchange-sensitive microstructural mapping, establishing a model-agnostic optimization framework adaptable to future ultra-high gradient systems and existing clinical scanners.

physics.med-ph

Unveiling Normative Trajectories of Lifespan Brain Maturation Using Quantitative MRI

Background: Brain maturation and aging involve significant microstructural changes, resulting in functional and cognitive alterations. Quantitative MRI (qMRI) can measure this evolution, distinguishing the physiological effects of normal aging from pathological deviations. Methods: We conducted a multicentre study using qMRI metrics (R1, R2*, and Quantitative Susceptibility Mapping) to model age trajectories across brain structures, including tractography-based white matter bundles (TWMB), superficial white matter (SWM), and cortical grey matter (CGM). MRI data from 537 healthy subjects, aged 8 to 79 years, were harmonized using two independent methods. We modeled age trajectories and performed regional analyses to capture maturation patterns and aging effects across the lifespan. Findings: Our findings revealed a distinct brain maturation gradient, with early qMRI peak values in TWMB, followed by SWM, and culminating in CGM regions. This gradient was observed as a posterior-to-anterior maturation pattern in the cortex and an inferior-to-superior maturation pattern in white matter tracts. R1 demonstrated the most robust age trajectories, while R2* and susceptibility exhibited greater variability and different patterns. The normative modeling framework confirmed the reliability of our age-modelled trajectories across datasets. Interpretation: Our study highlights the potential of multiparametric qMRI to capture complex, region-specific brain development patterns, addressing the need for comprehensive, age-spanning studies across multiple brain structures. Various harmonization strategies can merge qMRI cohorts, improving the robustness of qMRI-based age models and facilitating the understanding of normal patterns and disease-associated deviations.

physics.med-ph

Recommended Implementation of Quantitative Susceptibility Mapping for Clinical Research in The Brain: A Consensus of the ISMRM Electro-Magnetic Tissue Properties Study Group

This article provides recommendations for implementing quantitative susceptibility mapping (QSM) for clinical brain research. It is a consensus of the ISMRM Electro-Magnetic Tissue Properties Study Group. While QSM technical development continues to advance rapidly, the current QSM methods have been demonstrated to be repeatable and reproducible for generating quantitative tissue magnetic susceptibility maps in the brain. However, the many QSM approaches available give rise to the need in the neuroimaging community for guidelines on implementation. This article describes relevant considerations and provides specific implementation recommendations for all steps in QSM data acquisition, processing, analysis, and presentation in scientific publications. We recommend that data be acquired using a monopolar 3D multi-echo GRE sequence, that phase images be saved and exported in DICOM format and unwrapped using an exact unwrapping approach. Multi-echo images should be combined before background removal, and a brain mask created using a brain extraction tool with the incorporation of phase-quality-based masking. Background fields should be removed within the brain mask using a technique based on SHARP or PDF, and the optimization approach to dipole inversion should be employed with a sparsity-based regularization. Susceptibility values should be measured relative to a specified reference, including the common reference region of whole brain as a region of interest in the analysis, and QSM results should be reported with - as a minimum - the acquisition and processing specifications listed in the last section of the article. These recommendations should facilitate clinical QSM research and lead to increased harmonization in data acquisition, analysis, and reporting.

physics.med-ph