SearcharxivSearch

arXiv subjects

Kyujin Cho

Publications and source records attributed to Kyujin Cho.

2 recordsLinked to original sources

From Detection to Recovery: Operational Analysis on LLM Pre-training with 504 GPUs

Large-scale AI training is fundamentally a distributed systems problem, where hardware failures are routine operating conditions rather than rare exceptions, yet public operational evidence from production training clusters remains limited. This report presents an empirical analysis of a 63-node NVIDIA B200 production cluster (504 GPUs), using 55 days of Prometheus time-series data and 73 days of operational logs covering 224 multi-node training sessions. The environment is cross-organizational: five parties (SKT, Upstage, Lablup, NVIDIA Korea, VAST Data) share a unified monitoring pipeline. This enabled joint diagnosis of a 60-node-scale storage I/O bottleneck absent in 2-4-node tests, a production-scale phenomenon no single team could isolate alone. We perform three quantitative analyses yielding four findings. First, over 751 Prometheus metrics and 10 XID-identified GPU failures, no single metric is consistently dominant across failure types, motivating multi-signal detection. Second, 523 checkpoint events trace the save/load path from GPU VRAM to the NFS server: restart loading reaches 21.5% of maximum read bandwidth (700 GB/s) and save bursts 16.0% of maximum write bandwidth (250 GB/s), with NFS/RPC queueing and transport-layer backlog rising together. Third, across 224 sessions over 73 days, node exclusions concentrate so the top 3 of 63 nodes account for over 50%. Fourth, auto-retry chain analysis shows a 33.3% success rate over 12 chains (73 attempts), 2.7x the 12.5% manual rate, with a median retry interval of 11 minutes (IQR 10-11). All analyses are grounded in production infrastructure providing session-level workload management, GPU-centric scheduling, and unified observability.

cs.DC

Effects of Wrist-Worn Haptic Feedback on Force Accuracy and Task Speed during a Teleoperated Robotic Surgery Task

Previous work has shown that the addition of haptic feedback to the hands can improve awareness of tool-tissue interactions and enhance performance of teleoperated tasks in robot-assisted minimally invasive surgery. However, hand-based haptic feedback occludes direct interaction with the manipulanda of surgeon console in teleoperated surgical robots. We propose relocating haptic feedback to the wrist using a wearable haptic device so that haptic feedback mechanisms do not need to be integrated into the manipulanda. However, it is unknown if such feedback will be effective, given that it is not co-located with the finger movements used for manipulation. To test if relocated haptic feedback improves force application during teleoperated tasks using da Vinci Research Kit (dVRK) surgical robot, participants learned to palpate a phantom tissue to desired forces. A soft pneumatic wrist-worn haptic device with an anchoring system renders tool-tissue interaction forces to the wrist of the user. Participants performed the palpation task with and without wrist-worn haptic feedback and were evaluated for the accuracy of applied forces. Participants demonstrated statistically significant lower force error when wrist-worn haptic feedback was provided. Participants also performed the palpation task with longer movement times when provided wrist-worn haptic feedback, indicating that the haptic feedback may have caused participants to operate at a different point in the speed-accuracy tradeoff curve.

cs.RO