SearcharxivSearch

arXiv subjects

L. Althueser

Publications and source records attributed to L. Althueser.

At least 19 recordsLinked to original sources

First Measurement of Solar Neutrinos through Elastic Neutrino-Electron Scattering at the keV Scale

We report on the first measurement of low-energy solar neutrinos through elastic neutrino-electron scattering in a dark matter experiment, establishing the lowest energy threshold for any neutrino detection to date. The measurement utilizes data from the first two science runs of XENONnT, corresponding to an exposure of 2.46 t $\cdot$ y, and covers electron recoil energies between 1 keV and 140 keV, providing sensitivity to solar neutrinos with energies down to 17 keV. We reject the background-only hypothesis with a statistical significance of $5.0\sigma$ and measure a solar $pp$ neutrino flux of $(10.2 \pm 2.0) \times 10^{10}$ cm$^{-2}$ s$^{-1}$. The result is larger, but statistically consistent with the previous measurement by Borexino at $1.9\sigma$. Together with recent observations of coherent elastic neutrino-nucleus scattering of $^8$B solar neutrinos in XENONnT and other liquid-xenon time projection chambers, these results demonstrate the growing potential of liquid xenon detectors for neutrino physics down to the keV-scale and represent an important milestone towards a next-generation multipurpose observatory.

hep-ex

Search for Magnetic and Spin-Independent Inelastic Dark Matter with XENONnT

We present a search for Magnetic and Spin-Independent inelastic Dark Matter using 2.1 tonne-years of data from the XENONnT experiment. We consider both single- and double-site event topologies, targeting the unique signature of an initial nuclear recoil followed by a delayed de-excitation photon. To suppress backgrounds, we introduce novel directional and kinematic selections based on the inferred speed and direction of the excited dark matter particle between the scatter and decay sites. We find that the collected data are consistent with background expectations, and report 90% C.L. upper limits for both models across the GeV/c2-TeV/c2 mass range.

hep-ex

HERETIX: A Hermetic, Enriched, Rare-Event Time Projection Chamber in Xenon

Xenon-based time projection chambers have established themselves as one of the most powerful technologies for rare-event searches. HERETIX is a proposed multi-tonne liquid xenon observatory featuring two nested time projection chambers that enable the simultaneous optimisation of searches for weakly interacting massive particles and neutrinoless double beta decay ($0\nu\beta\beta$) of $^{136}$Xe. A hermetically sealed sapphire vessel containing xenon enriched to 90% $^{136}$Xe forms the inner detector, providing an ultra-low-background environment for $0\nu\beta\beta$ searches. Monte Carlo studies indicate that material-induced backgrounds can be effectively eliminated, yielding a projected $0\nu\beta\beta$ half-life sensitivity of $3.2 \times 10^{28} \, \mathrm{years}$ at 90% confidence level after a 10-year exposure, while the surrounding xenon volume, depleted in $^{136}$Xe, preserves the excellent dark matter sensitivity of large liquid xenon detectors. HERETIX therefore offers a unified experimental approach capable of delivering leading sensitivity to two of the most compelling questions in fundamental physics.

physics.ins-det

Direct Measurement of the $^{212}\mathrm{Pb}$ and $^{214}\mathrm{Pb}$ $\beta$ Decay Branching Ratios with the XENONnT Experiment

We present precision measurements of $^{212}\mathrm{Pb}$ and $^{214}\mathrm{Pb}$ $\beta$ decay branching ratios using $^{220}\mathrm{Rn}$ and $^{222}\mathrm{Rn}$ calibration data from the XENONnT detector, a dual-phase liquid xenon time projection chamber. Characterizing these isotopes is critical, as they lead to significant low-energy backgrounds in rare-event searches. We report ground-state branching ratios of $(14.75 \pm 0.20(\mathrm{stat}) ^{+0.14}_{-0.40}(\mathrm{sys}))\%$ for $^{212}\mathrm{Pb}$ and $(9.8 \pm 0.3(\mathrm{stat}) ^{+0.8}_{-0.2}(\mathrm{sys}))\%$ for $^{214}\mathrm{Pb}$, providing the most precise direct measurements of these transitions to date. These results contribute to enhancing background modeling for dark matter and neutrino experiments, improving sensitivity to solar neutrinos and physics beyond the Standard Model.

nucl-ex

Low-Energy Nuclear Recoil Calibration of XENONnT with a $^{88}$YBe Photoneutron Source

Characterizing low-energy, keV-range nuclear recoils near the detector threshold is one of the major challenges for large direct dark matter detectors. To that end, we have successfully used a Yttrium-Beryllium photoneutron source that emits 152 keV neutrons for the calibration of the light and charge yields of the XENONnT experiment for the first time. After data selection, we accumulated 474 events from 183 hours of exposure with this source. The expected background was $55 \pm 12$ accidental coincidence events, estimated using a dedicated 152 hour background calibration run with a Yttrium-PVC gamma-only source and data-driven modeling. From these calibrations, we extracted the light (charge) yield for liquid xenon at our field strength of 23 V/cm between 0.3 (0.7) keV$_{\rm NR}$ and 5.0 keV$_{\rm NR}$. This calibration is crucial for accurately measuring the solar $^8$B neutrino coherent elastic neutrino-nucleus scattering and searching for light dark matter particles with masses below 12 GeV/c$^2$.

physics.ins-det

Proof-of-concept of a xenon-based cryogenic heat pump demonstrator for future liquid xenon observatories

This manuscript details the proof-of-concept of a small-scale cryogenic heat pump demonstrator, a technology designed to enable high-flow xenon distillation systems for the removal of $^{222}$Rn in future liquid xenon observatories such as the XLZD experiment. The heat pump demonstrator operates on a left-turning Clausius-Rankine cycle, utilizing xenon as a phase-changing working medium. The design aims to fully hermetically separate the heat pump from the radon removal system, simplifying material cleanliness and maintenance compared to currently operating systems. Two demonstration tests were conducted at nominal pressures of $3.3\,\mathrm{bar}$ and $4.3\,\mathrm{bar}$, utilizing a cold head and electrical heaters to mimic the behavior of a xenon distillation system. In both measurements, the demonstrator achieved a cooling and heating power of $(118\pm3)\,\mathrm{W}$ and $(121\pm3)\,\mathrm{W}$, respectively. This is sufficient to operate a small distillation system with a virtual purification mass flow of about $3.1\,\mathrm{kg/h}$, while consuming $386\pm1\,\mathrm{W}$ electrical power. Compered to currently operating applications using commercial cold heads driven by helium compressors, which typically require about $6\,\mathrm{kW}$ of electrical power, this is significantly lower. The presented proof-of-concept heat pump demonstrator is further put into perspective with the currently planned XLZD experiment using a simplified scaling model. This model indicates that a radon removal system with a purification mass flow of $1600\,\mathrm{kg/h}$ and a required cooling and heating power of about $60\,\mathrm{kW}$ each, will be sufficient to cover a variety of different detector masses and background conditions.

physics.ins-det

Probing the Solar $^8$B Neutrino Fog with XENONnT

We report a 3.3 $\sigma$ measurement of coherent elastic neutrino-nucleus scattering from solar $^8$B neutrinos using a 6.77 t$\times$yr exposure from the XENONnT experiment, inferring a solar $^8$B neutrino flux of $(5_{-2}^{+3})\times 10^6\,\mathrm{cm}^{-2}\mathrm{s}^{-1}$, consistent with previous measurements. In the presence of the $^8$B "neutrino fog", we find no evidence for light dark matter, and observe diminishing returns in sensitivity with increasing exposure. A 93% increase in exposure from the previous search improves the median sensitivity to the nucleon scattering cross section for a 5 GeV/$c^2$ spin-independent weakly interacting massive particle by 10%. The dataset was also used to measure the weak mixing angle at $\sim$ 0.02 GeV/$c$ momentum transfer and constrain physics beyond the Standard Model.

hep-ex

Challenging Spontaneous Quantum Collapse with XENONnT

We report on the search for X-ray radiation as predicted from dynamical quantum collapse with low-energy electronic recoil data in the energy range of 1-140 keV from the first science run of the XENONnT dark matter detector. Spontaneous radiation is an unavoidable effect of dynamical collapse models, which were introduced as a possible solution to the long-standing measurement problem in quantum mechanics. The analysis utilizes a model that for the first time accounts for cancellation effects in the emitted spectrum, which arise in the X-ray range due to the opposing electron-proton charges in xenon atoms. New world-leading limits on the free parameters of the Markovian continuous spontaneous localization and Diósi-Penrose models are set, improving previous best constraints by two orders of magnitude and a factor of five, respectively. The original values proposed for the strength and the correlation length of the continuous spontaneous localization model are excluded experimentally for the first time.

hep-ex

Enhancing Neutrinoless Double-Beta Decay Sensitivity of Liquid-Xenon Time Projection Chamber with Augmented Convolutional Neural Network

Dual-phase time projection chamber (TPC) that employs a multi-ton-scale liquid xenon (LXe) target mass is a pioneering detector technology to search for dark matter. Beyond its advantage in dark matter direct detection efforts, the natural xenon target allows it to search for the neutrinoless double-beta decay ($0νββ$) process, which would violate lepton number conservation and indicate that neutrinos are Majorana particles. However, such $0νββ$ searches have been limited by gamma-ray backgrounds originating from the detector materials. In this work, we designed an augmented convolutional neural network (A-CNN) model to extract additional event-topology information from detector data. Using simulation and calibration data from XENONnT, a leading LXe TPC experiment, our model achieved over 60% background rejection while maintaining 90% signal acceptance. This rejection power improves XENONnT's projected sensitivity of the $^{136}$Xe $0νββ$ search by about 40%. The implementation of A-CNN in the data analysis of future liquid xenon observatories, such as XLZD, will further enhance their sensitivities for $0νββ$ with $^{136}$Xe.

physics.ins-det

Light Dark Matter Search with 7.8 Tonne-Year of Ionization-Only Data in XENONnT

We report on a blinded search for dark matter (DM) using ionization-only (S2-only) signals in XENONnT with a total exposure of $7.83\mathrm{tonne}\times\mathrm{year}$ over 579 days in three science runs. Dedicated background suppression techniques and the first complete S2-only background model in XENONnT provide sensitivity to nuclear recoils of [0.5, 5.0] $\mathrm{keV_\mathrm{nr}}$ and electronic recoils of [0.04, 0.7] $\mathrm{keV_\mathrm{ee}}$. No significant excess over the expected background is observed, and we set 90\% confidence level upper limits on spin-independent DM--nucleon and spin-dependent DM--neutron scattering for DM masses between 3 and 8 $\mathrm{GeV}/c^2$, as well as on DM--electron scattering, axion-like particles, and dark photons, improving on previous constraints. For spin-independent DM--nucleon scattering, we exclude cross sections above $6.0\times10^{-45} $cm$^2$ at a DM mass of 5 $\mathrm{GeV}/c^2$, pushing the XENONnT sensitivity closer to the region where coherent elastic neutrino-nucleus scattering ($\text{CE}\nu\text{NS}$) becomes an irreducible background.

hep-ex

Constraints on Solar Reflected Dark Matter from a combined analysis of XENON1T and XENONnT data

We report on a search for sub-GeV dark matter upscattered via the solar reflection mechanism in the heavy mediator scenario. Under the Standard Halo Model, keV to MeV dark matter produces nuclear recoils with energies below the detection threshold of liquid xenon time projection chambers. We enhance sensitivity to low-mass dark matter by considering dark matter-electron scattering, employing dedicated event selections to reduce the detection threshold, and exploiting the additional kinetic energy imparted to the dark matter particle by solar upscattering. Using XENON1T ionization-only and XENONnT low-energy electronic recoil datasets, we exclude previously unconstrained DM-electron scattering cross section for masses between $4.6\, \text{keV/}c^2$ and $20\, \text{keV/}c^2$, and between $0.2\, \text{MeV/}c^2$ and $2\, \text{MeV/}c^2$, reaching a minimum of $3.41\times10^{-39}\, \text{cm}^2$ for a mass of $0.3\, \text{MeV/}c^2$ at 90\% confidence level.

hep-ex

WIMP Dark Matter Search using a 3.1 Tonne-Year Exposure of the XENONnT Experiment

We report on a search for weakly interacting massive particle (WIMP) dark matter (DM) via elastic DM-xenon-nucleus interactions in the XENONnT experiment. We combine datasets from the first and second science campaigns resulting in a total exposure of 3.1 tonne-years. In a blind analysis of nuclear recoil events with energies above $3.8\,\mathrm{keV_{NR}}$, we find no significant excess above background. We set new upper limits on the spin-independent WIMP-nucleon scattering cross section for WIMP masses above $10\,\mathrm{GeV}/c^2$ with a minimum of $1.7\,\times\,10^{-47}\,\mathrm{cm^2}$ at $90\,\%$ confidence level for a WIMP mass of $30\,\mathrm{GeV}/c^2$. We achieve a best median sensitivity of $1.4\,\times\,10^{-47}\,\mathrm{cm^2}$ for a $41\,\mathrm{GeV}/c^2$ WIMP. Compared to the result from the first XENONnT science dataset, we improve our sensitivity by a factor of up to 1.8.

hep-ex

The XLZD Design Book: Towards the Next-Generation Liquid Xenon Observatory for Dark Matter and Neutrino Physics

This report describes the experimental strategy and technologies for XLZD, the next-generation xenon observatory sensitive to dark matter and neutrino physics. In the baseline design, the detector will have an active liquid xenon target of 60 tonnes, which could be increased to 80 tonnes if the market conditions for xenon are favorable. It is based on the mature liquid xenon time projection chamber technology used in current-generation experiments, LZ and XENONnT. The report discusses the baseline design and opportunities for further optimization of the individual detector components. The experiment envisaged here has the capability to explore parameter space for Weakly Interacting Massive Particle (WIMP) dark matter down to the neutrino fog, with a 3$σ$ evidence potential for WIMP-nucleon cross sections as low as $3\times10^{-49}\rm\,cm^2$ (at 40 GeV/c$^2$ WIMP mass). The observatory will also have leading sensitivity to a wide range of alternative dark matter models. It is projected to have a 3$σ$ observation potential of neutrinoless double beta decay of $^{136}$Xe at a half-life of up to $5.7\times 10^{27}$ years. Additionally, it is sensitive to astrophysical neutrinos from the sun and galactic supernovae.

hep-ex

Spectral Measurement of the $^{214}$Bi beta-decay to the $^{214}$Po Ground State with XENONnT

We report the measurement of the $^{214}$Bi beta-decay spectrum to the ground state of $^{214}$Po using the XENONnT detector. This decay is classified as first-forbidden non-unique, for which theoretical predictions require detailed nuclear structure modeling. A dedicated identification algorithm isolates a high-purity sample of ground-state beta-decays, explicitly excluding events with associated gamma-rays emission. By comparing the measured spectrum, which covers energies up to 3.27 MeV, with several nuclear models, we find that the prediction based on the conserved vector current (CVC) hypothesis provides the best description of the data. Using this dataset, we additionally derive charge and light yield curves for electronic recoils, extending detector response modeling up to the MeV scale.

nucl-ex

The XENONnT Dark Matter Experiment

The multi-staged XENON program at INFN Laboratori Nazionali del Gran Sasso aims to detect dark matter with two-phase liquid xenon time projection chambers of increasing size and sensitivity. The XENONnT experiment is the latest detector in the program, planned to be an upgrade of its predecessor XENON1T. It features an active target of 5.9 tonnes of cryogenic liquid xenon (8.5 tonnes total mass in cryostat). The experiment is expected to extend the sensitivity to WIMP dark matter by more than an order of magnitude compared to XENON1T, thanks to the larger active mass and the significantly reduced background, improved by novel systems such as a radon removal plant and a neutron veto. This article describes the XENONnT experiment and its sub-systems in detail and reports on the detector performance during the first science run.

physics.ins-det

XENONnT WIMP Search: Signal & Background Modeling and Statistical Inference

The XENONnT experiment searches for weakly-interacting massive particle (WIMP) dark matter scattering off a xenon nucleus. In particular, XENONnT uses a dual-phase time projection chamber with a 5.9-tonne liquid xenon target, detecting both scintillation and ionization signals to reconstruct the energy, position, and type of recoil. A blind search for nuclear recoil WIMPs with an exposure of 1.1 tonne-years (4.18 t fiducial mass) yielded no signal excess over background expectations, from which competitive exclusion limits were derived on WIMP-nucleon elastic scatter cross sections, for WIMP masses ranging from 6 GeV/$c^2$ up to the TeV/$c^2$ scale. This work details the modeling and statistical methods employed in this search. By means of calibration data, we model the detector response, which is then used to derive background and signal models. The construction and validation of these models is discussed, alongside additional purely data-driven backgrounds. We also describe the statistical inference framework, including the definition of the likelihood function and the construction of confidence intervals.

physics.data-an

Neutrinoless Double Beta Decay Sensitivity of the XLZD Rare Event Observatory

The XLZD collaboration is developing a two-phase xenon time projection chamber with an active mass of 60 to 80 t capable of probing the remaining WIMP-nucleon interaction parameter space down to the so-called neutrino fog. In this work we show that, based on the performance of currently operating detectors using the same technology and a realistic reduction of radioactivity in detector materials, such an experiment will also be able to competitively search for neutrinoless double beta decay in $^{136}$Xe using a natural-abundance xenon target. XLZD can reach a 3$σ$ discovery potential half-life of 5.7$\times$10$^{27}$ yr (and a 90% CL exclusion of 1.3$\times$10$^{28}$ yr) with 10 years of data taking, corresponding to a Majorana mass range of 7.3-31.3 meV (4.8-20.5 meV). XLZD will thus exclude the inverted neutrino mass ordering parameter space and will start to probe the normal ordering region for most of the nuclear matrix elements commonly considered by the community.

physics.ins-det

Search for Light Dark Matter in Low-Energy Ionization Signals from XENONnT

We report on a blinded search for dark matter with single- and few-electron signals in the first science run of XENONnT relying on a novel detector response framework that is physics-model-dependent. We derive 90\% confidence upper limits for dark matter-electron interactions. Heavy and light mediator cases are considered for the standard halo model and dark matter up-scattered in the Sun. We set stringent new limits on dark matter-electron scattering via a heavy mediator with a mass within 10-20\,MeV/$c^2$ and electron absorption of axion-like particles and dark photons for $m_χ$ below 0.186\,keV/$c^2$.

hep-ex