SearcharxivSearch

arXiv subjects

L. Bezrukov

Publications and source records attributed to L. Bezrukov.

At least 19 recordsLinked to original sources

Energy Calibration and Performance of HPGe Detectors in the LEGEND-200 Experiment

This paper describes the energy scale procedures and germanium detectors performance in the LEGEND-200 experiment, a critical component for the first unblinding in the search for neutrinoless double beta decay. We detail the digital signal processing pipeline, the methodologies for peak-shape modeling and energy calibration procedures utilizing weekly $^{228}$Th source calibration runs. The optimized energy reconstruction achieves a combined average resolution of $(2.47 \pm 0.08)$~keV at $Q_{\beta\beta} = 2039$~keV. The weekly variation of calibration peak positions are below 0.05~keV for energies up to 2614.5~keV, showing a high stability of the energy scale over time and across detectors. Furthermore, systematic corrections effectively address residual non-linearities and energy bias in the region of interest.

physics.ins-det

First Measurement of Neutrino Emissions from Spent Nuclear Fuel by the Double Chooz Experiment

Neutrino emission from nuclear reactors provides real-time insights into reactor power and fuel evolution, with potential applications in monitoring and nuclear safeguards. Following reactor shutdown, a low-intensity flux of ``residual neutrinos'' persists due to the decay of long-lived fission isotopes in the partially burnt fuel remaining within the reactor cores and in spent nuclear fuel stored in nearby cooling pools. The Double Chooz experiment at the Chooz B nuclear power plant in France achieved the first quantitative measurement of this residual flux based on 17.2 days of reactor-off data. In the energy range where the residual signal is most pronounced, the neutrino detector located 400$\,$m from the cores recorded $106 \pm 18$ neutrino candidate events (5.9$\sigma$ significance). This measurement is in excellent agreement with the predicted value of $88 \pm 7$ events derived from detailed reactor simulations modeling the decay activities of fission products and incorporating the best-available models of neutrino spectra.

hep-ex

Search for the in-situ production of $^{77}$Ge in the GERDA neutrinoless double-beta decay experiment

The beta decay of $^{77}$Ge and $^{77\mathrm{m}}$Ge, both produced by neutron capture on $^{76}$Ge, is a potential background for Germanium based neutrinoless double-beta decay search experiments such as GERDA or the LEGEND experiment. In this work we present a search for $^{77}$Ge decays in the full GERDA Phase II data set. A delayed coincidence method was employed to identify the decay of $^{77}$Ge via the isomeric state of $^{77}$As (9/2$^+$, 475 keV, ${T_{1/2} = 114}\,\mu $s, $^{77\mathrm{m}}$As). New digital signal processing methods were employed to select and analyze pile-up signals. No signal was observed, and an upper limit on the production rate of was set at $<0.216$ nuc/(kg$\cdot$yr) (90% CL). This corresponds to a total production rate of $^{77}$Ge and $^{77\mathrm{m}}$Ge of $<0.38$ nuc/(kg$\cdot$ yr) (90% CL), assuming equal production rates. A previous Monte Carlo study predicted a value for in-situ $^{77}$Ge and $^{77\mathrm{m}}$Ge production of (0.21$\pm$0.07) nuc/(kg$\cdot$yr), a prediction that is now further corroborated by our experimental limit. Moreover, tagging the isomeric state of $^{77\mathrm{m}}$As can be utilised to further suppress the $^{77}$Ge background. Considering the similar experimental configurations of LEGEND-1000 and GERDA, the cosmogenic background in LEGEND-1000 at LNGS is estimated to remain at a sub-dominant level.

nucl-ex

First Results on the Search for Lepton Number Violating Neutrinoless Double Beta Decay with the LEGEND-200 Experiment

The LEGEND collaboration is searching for neutrinoless double beta ($0\nu\beta\beta$) decay by operating high-purity germanium detectors enriched in $^{76}$Ge in a low-background liquid argon environment. Building on key technological innovations from GERDA and the MAJORANA DEMONSTRATOR, LEGEND-200 has performed a first $0\nu\beta\beta$ decay search based on 61.0 kg yr of data. Over half of this exposure comes from our highest performing detectors, including newly developed inverted-coaxial detectors, and is characterized by an estimated background level of $0.5^{+0.3}_{-0.2}$ cts/(keV kg yr) in the $0\nu\beta\beta$ decay signal region. A combined analysis of data from GERDA, the MAJORANA DEMONSTRATOR, and LEGEND-200, characterized by a 90% confidence level exclusion sensitivity of $2.8 \times 10^{26}$ yr on the half-life of $0\nu\beta\beta$ decay, reveals no evidence for a signal and sets a new observed lower limit at $T^{0\nu}_{1/2} > 1.9 \times 10^{26}$ yr (90% confidence level). Assuming the decay is mediated by Majorana neutrinos, this corresponds to an upper limit on the effective Majorana mass in the range $m_{\beta\beta} < 75-200$ meV, depending on the adopted nuclear matrix element.

hep-ex

Searches for new physics below twice the electron mass with GERDA

A search for full energy depositions from bosonic keV-scale dark matter candidates of masses between 65 keV and 1021 keV has been performed with data collected during Phase II of the GERmanium Detector Array (GERDA) experiment. Our analysis includes direct dark matter absorption as well as dark Compton scattering. With a total exposure of 105.5 kg yr, no evidence for a signal above the background has been observed. The resulting exclusion limits deduced with either Bayesian or Frequentist statistics are the most stringent direct constraints in the major part of the 140-1021 keV mass range. As an example, at a mass of 150 keV the dimensionless coupling of dark photons and axion-like particles to electrons has been constrained to $\alpha$'/$\alpha$ < 8.7x10$^{-24}$ and g$_{ae}$ < 3.3x10$^{-12}$ at 90% credible interval (CI), respectively. Additionally, a search for peak-like signals from beyond the Standard Model decays of nucleons and electrons is performed. We find for the inclusive decay of a single neutron in $^{76}$Ge a lower lifetime limit of $\tau_n$ > 1.5x10$^{24}$ yr and for a proton $\tau_p$ > 1.3x10$^{24}$ yr at 90% CI. For the electron decay e$^-\rightarrow\nu_e\gamma$ a lower limit of $\tau_e$ > 5.4x10$^{25}$ yr at 90% CI has been determined.

nucl-ex

An improved limit on the neutrinoless double-electron capture of $^{36}$Ar with GERDA

The GERmanium Detector Array (GERDA) experiment operated enriched high-purity germanium detectors in a liquid argon cryostat, which contains 0.33% of $^{36}$Ar, a candidate isotope for the two-neutrino double-electron capture (2$\nu$ECEC) and therefore for the neutrinoless double-electron capture (0$\nu$ECEC). If detected, this process would give evidence of lepton number violation and the Majorana nature of neutrinos. In the radiative 0$\nu$ECEC of $^{36}$Ar, a monochromatic photon is emitted with an energy of 429.88 keV, which may be detected by the GERDA germanium detectors. We searched for the $^{36}$Ar 0$\nu$ECEC with GERDA data, with a total live time of 4.34 yr (3.08 yr accumulated during GERDA Phase II and 1.26 yr during GERDA Phase I). No signal was found and a 90% C.L. lower limit on the half-life of this process was established T$_{1/2}$ > 1.5x10$^{22}$ yr

nucl-ex

Final Results of GERDA on the Two-Neutrino Double-$\beta$ Decay Half-Life of $^{76}$Ge

We present the measurement of the two-neutrino double-$\beta$ decay rate of $^{76}$Ge performed with the GERDA Phase II experiment. With a subset of the entire GERDA exposure, 11.8 kg$\cdot$yr, the half-life of the process has been determined: $T^{2\nu}_{1/2} = (2.022 \pm 0.018_{stat} \pm 0.038_{sys})\times10^{21}$ yr. This is the most precise determination of the $^{76}$Ge two-neutrino double-$\beta$ decay half-life and one of the most precise measurements of a double-$\beta$ decay process. The relevant nuclear matrix element can be extracted: $M^{2\nu}_{\text{eff}} = (0.101\pm0.001).$

nucl-ex

Search for tri-nucleon decays of $^{76}$Ge in GERDA

We search for tri-nucleon decays of $^{76}$Ge in the dataset from the GERmanium Detector Array (GERDA) experiment. Decays that populate excited levels of the daughter nucleus above the threshold for particle emission lead to disintegration and are not considered. The ppp-, ppn-, and pnn-decays lead to $^{73}$Cu, $^{73}$Zn, and $^{73}$Ga nuclei, respectively. These nuclei are unstable and eventually proceed by the beta decay of $^{73}$Ga to $^{73}$Ge (stable). We search for the $^{73}$Ga decay exploiting the fact that it dominantly populates the 66.7 keV $^{73m}$Ga state with half-life of 0.5 s. The nnn-decays of $^{76}$Ge that proceed via $^{73m}$Ge are also included in our analysis. We find no signal candidate and place a limit on the sum of the decay widths of the inclusive tri-nucleon decays that corresponds to a lower lifetime limit of 1.2x10$^{26}$ yr (90% credible interval). This result improves previous limits for tri-nucleon decays by one to three orders of magnitude.

nucl-ex

Liquid argon light collection and veto modeling in GERDA Phase II

The ability to detect liquid argon scintillation light from within a densely packed high-purity germanium detector array allowed the GERDA experiment to reach an exceptionally low background rate in the search for neutrinoless double beta decay of $^{76}$Ge. Proper modeling of the light propagation throughout the experimental setup, from any origin in the liquid argon volume to its eventual detection by the novel light read-out system, provides insight into the rejection capability and is a necessary ingredient to obtain robust background predictions. In this paper, we present a model of the GERDA liquid argon veto, as obtained by Monte Carlo simulations and constrained by calibration data, and highlight its application for background decomposition.

physics.ins-det

Search for exotic physics in double-$\beta$ decays with GERDA Phase II

A search for Beyond the Standard Model double-$\beta$ decay modes of $^{76}$Ge has been performed with data collected during the Phase II of the GERmanium Detector Array (GERDA) experiment, located at Laboratori Nazionali del Gran Sasso of INFN (Italy). Improved limits on the decays involving Majorons have been obtained, compared to previous experiments with $^{76}$Ge, with half-life values on the order of 10$^{23}$ yr. For the first time with $^{76}$Ge, limits on Lorentz invariance violation effects in double-$\beta$ decay have been obtained. The isotropic coefficient $\mathring{a}_\text{of}^{(3)}$, which embeds Lorentz violation in double-$\beta$ decay, has been constrained at the order of $10^{-6}$ GeV. We also set the first experimental limits on the search for light exotic fermions in double-$\beta$ decay, including sterile neutrinos.

nucl-ex

Pulse shape analysis in GERDA Phase II

The GERmanium Detector Array (GERDA) collaboration searched for neutrinoless double-$\beta$ decay in $^{76}$Ge using isotopically enriched high purity germanium detectors at the Laboratori Nazionali del Gran Sasso of INFN. After Phase I (2011-2013), the experiment benefited from several upgrades, including an additional active veto based on LAr instrumentation and a significant increase of mass by point-contact germanium detectors that improved the half-life sensitivity of Phase II (2015-2019) by an order of magnitude. At the core of the background mitigation strategy, the analysis of the time profile of individual pulses provides a powerful topological discrimination of signal-like and background-like events. Data from regular $^{228}$Th calibrations and physics data were both considered in the evaluation of the pulse shape discrimination performance. In this work, we describe the various methods applied to the data collected in GERDA Phase II corresponding to an exposure of 103.7 kg$\cdot$yr. These methods suppress the background by a factor of about 5 in the region of interest around Q$_{\beta\beta}$ = 2039 keV, while preserving (81$\pm$3)% of the signal. In addition, an exhaustive list of parameters is provided which were used in the final data analysis.

physics.ins-det

Potassium abundance in the Earth and Borexino data

An independent analysis of Borexino single event energy spectrum of recoil electrons and alphas was carried out. We compared two sets of single event sources. The first set is similar to the one used in Borexino Collaboration analysis. The second set additionally includes the scattering of $^{40}$K-geo-($\bar{\nu} + \nu$) on scintillator electrons. We found two equivalent minima for $\chi^2$ for second set. The one is for total counting rates $R(^{40}$K-geo-$(\bar{\nu} + \nu)) = 0.0$ and $R(^{210}$Bi) = 10 cpd/100t. The other one is for $R(^{40}$K-geo-$(\bar{\nu} + \nu)) = 7.05$ cpd/100t and $R(^{210}$Bi$) = 6$ cpd/100t. We performed MC pseudo-experiments and found that we do not have enough statistics and need to know the bismuth concentration in the scintillator for definite measurement of potassium abundance in the Earth. The possibility of building a next-generation detector for looking for the $^{40}$K-geo-($\bar{\nu} + \nu$) flux is being considered.

physics.ins-det

The Double Chooz antineutrino detectors

This article describes the setup and performance of the near and far detectors in the Double Chooz experiment. The electron antineutrinos of the Chooz nuclear power plant were measured in two identically designed detectors with different average baselines of about 400 m and 1050 m from the two reactor cores. Over many years of data taking the neutrino signals were extracted from interactions in the detectors with the goal of measuring a fundamental parameter in the context of neutrino oscillation, the mixing angle {\theta}13. The central part of the Double Chooz detectors was a main detector comprising four cylindrical volumes filled with organic liquids. From the inside towards the outside there were volumes containing gadolinium-loaded scintillator, gadolinium-free scintillator, a buffer oil and, optically separated, another liquid scintillator acting as veto system. Above this main detector an additional outer veto system using plastic scintillator strips was installed. The technologies developed in Double Chooz were inspiration for several other antineutrino detectors in the field. The detector design allowed implementation of efficient background rejection techniques including use of pulse shape information provided by the data acquisition system. The Double Chooz detectors featured remarkable stability, in particular for the detected photons, as well as high radiopurity of the detector components.

physics.ins-det

LEGEND-1000 Preconceptual Design Report

We propose the construction of LEGEND-1000, the ton-scale Large Enriched Germanium Experiment for Neutrinoless $\beta \beta$ Decay. This international experiment is designed to answer one of the highest priority questions in fundamental physics. It consists of 1000 kg of Ge detectors enriched to more than 90% in the $^{76}$Ge isotope operated in a liquid argon active shield at a deep underground laboratory. By combining the lowest background levels with the best energy resolution in the field, LEGEND-1000 will perform a quasi-background-free search and can make an unambiguous discovery of neutrinoless double-beta decay with just a handful of counts at the decay $Q$ value. The experiment is designed to probe this decay with a 99.7%-CL discovery sensitivity in the $^{76}$Ge half-life of $1.3\times10^{28}$ years, corresponding to an effective Majorana mass upper limit in the range of 9-21 meV, to cover the inverted-ordering neutrino mass scale with 10 yr of live time.

physics.ins-det

Characterization of inverted coaxial $^{76}$Ge detectors in GERDA for future double-$\beta$ decay experiments

Neutrinoless double-$\beta$ decay of $^{76}$Ge is searched for with germanium detectors where source and detector of the decay are identical. For the success of future experiments it is important to increase the mass of the detectors. We report here on the characterization and testing of five prototype detectors manufactured in inverted coaxial (IC) geometry from material enriched to 88% in $^{76}$Ge. IC detectors combine the large mass of the traditional semi-coaxial Ge detectors with the superior resolution and pulse shape discrimination power of point contact detectors which exhibited so far much lower mass. Their performance has been found to be satisfactory both when operated in vacuum cryostat and bare in liquid argon within the GERDA setup. The measured resolutions at the Q-value for double-$\beta$ decay of $^{76}$Ge (Q$_{\beta\beta}$ = 2039 keV) are about 2.1 keV full width at half maximum in vacuum cryostat. After 18 months of operation within the ultra-low background environment of the GERmanium Detector Array (GERDA) experiment and an accumulated exposure of 8.5 kg$\cdot$yr, the background index after analysis cuts is measured to be $4.9^{+7.3}_{-3.4}\times 10^{-4}$ counts /(keV$\cdot$kg$\cdot$yr) around Q$_{\beta\beta}$. This work confirms the feasibility of IC detectors for the next-generation experiment LEGEND.

physics.ins-det

Calibration of the GERDA experiment

The GERmanium Detector Array (GERDA) collaboration searched for neutrinoless double-$\beta$ decay in $^{76}$Ge with an array of about 40 high-purity isotopically-enriched germanium detectors. The experimental signature of the decay is a monoenergetic signal at Q$_{\beta\beta}$ = 2039.061(7)keV in the measured summed energy spectrum of the two emitted electrons. Both the energy reconstruction and resolution of the germanium detectors are crucial to separate a potential signal from various backgrounds, such as neutrino-accompanied double-$\beta$ decays allowed by the Standard Model. The energy resolution and stability were determined and monitored as a function of time using data from regular $^{228}$Th calibrations. In this work, we describe the calibration process and associated data analysis of the full GERDA dataset, tailored to preserve the excellent resolution of the individual germanium detectors when combining data over several years.

physics.ins-det

Final Results of GERDA on the Search for Neutrinoless Double-$\beta$ Decay

The GERmanium Detector Array (GERDA) experiment searched for the lepton-number-violating neutrinoless double-$\beta$ ($0\nu\beta\beta$) decay of $^{76}$Ge, whose discovery would have far-reaching implications in cosmology and particle physics. By operating bare germanium diodes, enriched in $^{76}$Ge, in an active liquid argon shield, GERDA achieved an unprecedently low background index of $5.2\times10^{-4}$ counts/(keV$\cdot$kg$\cdot$yr) in the signal region and met the design goal to collect an exposure of 100 kg$\cdot$yr in a background-free regime. When combined with the result of Phase I, no signal is observed after 127.2 kg$\cdot$yr of total exposure. A limit on the half-life of $0\nu\beta\beta$ decay in $^{76}$Ge is set at $T_{1/2}>1.8\times10^{26}$ yr at 90% C.L., which coincides with the sensitivity assuming no signal.

nucl-ex

Search for Signatures of Sterile Neutrinos with Double Chooz

We present a search for signatures of neutrino mixing of electron anti-neutrinos with additional hypothetical sterile neutrino flavors using the Double Chooz experiment. The search is based on data from 5 years of operation of Double Chooz, including 2 years in the two-detector configuration. The analysis is based on a profile likelihood, i.e.\ comparing the data to the model prediction of disappearance in a data-to-data comparison of the two respective detectors. The analysis is optimized for a model of three active and one sterile neutrino. It is sensitive in the typical mass range $5 \cdot 10^{-3} $ eV$^2 \lesssim \Delta m^2_{41} \lesssim 3\cdot 10^{-1} $ eV$^2$ for mixing angles down to $\sin^2 2\theta_{14} \gtrsim 0.02$. No significant disappearance additionally to the conventional disappearance related to $\theta_{13} $ is observed and correspondingly exclusion bounds on the sterile mixing parameter $\theta_{14} $ as function of $ \Delta m^2_{41} $ are obtained.

hep-ex