SearcharxivSearch

arXiv subjects

L. Carbone

Publications and source records attributed to L. Carbone.

At least 19 recordsLinked to original sources

Double-beta decay of ${}^{130}$Te to the first $0^+$ excited state of ${}^{130}$Xe with CUORE-0

We report on a search for double beta decay of $^{130}$Te to the first $0^{+}$ excited state of $^{130}$Xe using a 9.8 kg$\cdot$yr exposure of $^{130}$Te collected with the CUORE-0 experiment. In this work we exploit different topologies of coincident events to search for both the neutrinoless and two-neutrino double-decay modes. We find no evidence for either mode and place lower bounds on the half-lives: $\tau^{0\nu}_{0^+}>7.9\cdot 10^{23}$ yr and $\tau^{2\nu}_{0^+}>2.4\cdot 10^{23}$ yr. Combining our results with those obtained by the CUORICINO experiment, we achieve the most stringent constraints available for these processes: $\tau^{0\nu}_{0^+}>1.4\cdot 10^{24}$ yr and $\tau^{2\nu}_{0^+}>2.5\cdot 10^{23}$ yr.

nucl-ex

CUORE Sensitivity to $0\nu\beta\beta$ Decay

We report a study of the CUORE sensitivity to neutrinoless double beta ($0\nu\beta\beta$) decay. We used a Bayesian analysis based on a toy Monte Carlo (MC) approach to extract the exclusion sensitivity to the $0\nu\beta\beta$ decay half-life ($T_{1/2}^{0\nu}$) at $90\%$ credibility interval (CI) -- i.e. the interval containing the true value of $T_{1/2}^{0\nu}$ with $90\%$ probability -- and the $3 \sigma$ discovery sensitivity. We consider various background levels and energy resolutions, and describe the influence of the data division in subsets with different background levels. If the background level and the energy resolution meet the expectation, CUORE will reach a $90\%$ CI exclusion sensitivity of $2\cdot10^{25}$ yr with $3$ months, and $9\cdot10^{25}$ yr with $5$ years of live time. Under the same conditions, the discovery sensitivity after $3$ months and $5$ years will be $7\cdot10^{24}$ yr and $4\cdot10^{25}$ yr, respectively.

physics.ins-det

The projected background for the CUORE experiment

The Cryogenic Underground Observatory for Rare Events (CUORE) is designed to search for neutrinoless double beta decay of 130Te with an array of 988 TeO2 bolometers operating at temperatures around 10 mK. The experiment is currently being commissioned in Hall A of Laboratori Nazionali del Gran Sasso, Italy. The goal of CUORE is to reach a 90\% C.L. exclusion sensitivity on the \tect decay half-life of 9$\times$10$^{25}$ years after 5\,years of data taking. The main issue to be addressed to accomplish this aim is the rate of background events in the region of interest, which must not be higher than 10$^{-2}$\,counts/keV/kg/y. We developed a detailed Monte Carlo simulation, based on results from a campaign of material screening, radioassays, and bolometric measurements, to evaluate the expected background. This was used over the years to guide the construction strategies of the experiment and we use it here to project a background model for CUORE. In this paper we report the results of our study and our expectations for the background rate in the energy region where the peak signature of neutrinoless double beta decay of 130Te is expected.

physics.ins-det

The CUORE and CUORE-0 experiments at LNGS

The Cryogenic Underground Observatory for Rare Events (CUORE) is a 1-ton scale bolometric experiment devoted to the search of the neutrinoless double-beta decay (0{\nu}\b{eta}\b{eta}) in 130Te. The CUORE detector consists of an array of 988 TeO2 crystals operated at 10 mK. CUORE-0 is the CUORE demonstrator: it has been built to test the performance of the upcoming CUORE experiment and represents the largest 130Te bolometric setup ever operated. CUORE-0 has been running at Laboratori Nazionali del Gran Sasso (Italy) from 2013 to 2015. The final CUORE-0 analysis on 0{\nu}\b{eta}\b{eta} and the corresponding detector performance are presented. The present status of the CUORE experiment, now in its final construction and commissioning phase, are discussed. The results from assembly of the detector and the commissioning of the cryostat are reported.

physics.ins-det

Measurement of the Two-Neutrino Double Beta Decay Half-life of $^{130}$Te with the CUORE-0 Experiment

We report on the measurement of the two-neutrino double beta decay half-life of $^{130}$Te with the CUORE-0 detector. From an exposure of 33.4 kg$\cdot$y of TeO$_2$, the half-life is determined to be $T_{1/2}^{2\nu}$ = [8.2 $\pm$ 0.2 (stat.) $\pm$ 0.6 (syst.)] $\times$ 10$^{20}$y. This result is obtained after a detailed reconstruction of the sources responsible for the CUORE-0 counting rate, with a specific study of those contributing to the $^{130}$Te neutrinoless double beta decay region of interest.

nucl-ex

CUORE-0 detector: design, construction and operation

The CUORE experiment will search for neutrinoless double-beta decay of $^{130}$Te with an array of 988 TeO$_2$ bolometers arranged in 19 towers. CUORE-0, the first tower assembled according to the CUORE procedures, was built and commissioned at Laboratori Nazionali del Gran Sasso, and took data from March 2013 to March 2015. In this paper we describe the design, construction and operation of the CUORE-0 experiment, with an emphasis on the improvements made over a predecessor experiment, Cuoricino. In particular, we demonstrate with CUORE-0 data that the design goals of CUORE are within reach.

physics.ins-det

The Sensitivity of the Advanced LIGO Detectors at the Beginning of Gravitational Wave Astronomy

The Laser Interferometer Gravitational Wave Observatory (LIGO) consists of two widely separated 4 km laser interferometers designed to detect gravitational waves from distant astrophysical sources in the frequency range from 10 Hz to 10 kHz. The first observation run of the Advanced LIGO detectors started in September 2015 and ended in January 2016. A strain sensitivity of better than $10^{-23}/\sqrt{\text{Hz}}$ was achieved around 100 Hz. Understanding both the fundamental and the technical noise sources was critical for increasing the observable volume in the universe. The average distance at which coalescing binary black hole systems with individual masses of 30 $M_\odot$ could be detected was 1.3 Gpc. Similarly, the range for binary neutron star inspirals was about 75 Mpc. With respect to the initial detectors, the observable volume of Universe increased respectively by a factor 69 and 43. These improvements allowed Advanced LIGO to detect the gravitational wave signal from the binary black hole coalescence, known as GW150914.

astro-ph.IM

Analysis Techniques for the Evaluation of the Neutrinoless Double-Beta Decay Lifetime in $^{130}$Te with CUORE-0

We describe in detail the methods used to obtain the lower bound on the lifetime of neutrinoless double-beta ($0\nu\beta\beta$) decay in $^{130}$Te and the associated limit on the effective Majorana mass of the neutrino using the CUORE-0 detector. CUORE-0 is a bolometric detector array located at the Laboratori Nazionali del Gran Sasso that was designed to validate the background reduction techniques developed for CUORE, a next-generation experiment scheduled to come online in 2016. CUORE-0 is also a competitive $0\nu\beta\beta$ decay search in its own right and functions as a platform to further develop the analysis tools and procedures to be used in CUORE. These include data collection, event selection and processing, as well as an evaluation of signal efficiency. In particular, we describe the amplitude evaluation, thermal gain stabilization, energy calibration methods, and the analysis event selection used to create our final $0\nu\beta\beta$ decay search spectrum. We define our high level analysis procedures, with emphasis on the new insights gained and challenges encountered. We outline in detail our fitting methods near the hypothesized $0\nu\beta\beta$ decay peak and catalog the main sources of systematic uncertainty. Finally, we derive the $0\nu\beta\beta$ decay half-life limits previously reported for CUORE-0, $T^{0\nu}_{1/2}>2.7\times10^{24}$ yr, and in combination with the Cuoricino limit, $T^{0\nu}_{1/2}>4.0\times10^{24}$ yr.

nucl-ex

Localised excitation of a single photon source by a nanowaveguide

Nowadays, integrated photonics is a key technology in quantum information processing (QIP) but achieving all-optical buses for quantum networks with efficient integration of single photon emitters remains a challenge. Photonic crystals and cavities are good candidates but do not tackle how to effectively address a nanoscale emitter. Using a nanowire nanowaveguide, we realise an hybrid nanodevice which locally excites a single photon source (SPS). The nanowire acts as a passive or active sub-wavelength waveguide to excite the quantum emitter. Our results show that localised excitation of a SPS is possible and is compared with free-space excitation. Our proof of principle experiment presents an absolute addressing efficiency {\eta}a = 10-4 only 50% lower than the one using free-space optics. This important step demonstrates that sufficient guided light in a nanowaveguide made of a semiconductor nanowire is achievable to excite a single photon source. We accomplish a hybrid system offering great potentials for electrically driven SPSs and efficient single photon collection and detection, opening the way for optimum absorption/emission of nanoscale emitters. We also discuss how to improve the addressing efficiency of a dipolar nanoscale emitter with our system.

quant-ph

Search for Neutrinoless Double-Beta Decay of $^{130}$Te with CUORE-0

We report the results of a search for neutrinoless double-beta decay in a 9.8~kg$\cdot$yr exposure of $^{130}$Te using a bolometric detector array, CUORE-0. The characteristic detector energy resolution and background level in the region of interest are $5.1\pm 0.3{\rm~keV}$ FWHM and $0.058 \pm 0.004\,(\mathrm{stat.})\pm 0.002\,(\mathrm{syst.})$~counts/(keV$\cdot$kg$\cdot$yr), respectively. The median 90%~C.L. lower-limit sensitivity of the experiment is $2.9\times 10^{24}~{\rm yr}$ and surpasses the sensitivity of previous searches. We find no evidence for neutrinoless double-beta decay of $^{130}$Te and place a Bayesian lower bound on the decay half-life, $T^{0\nu}_{1/2}>$~$ 2.7\times 10^{24}~{\rm yr}$ at 90%~C.L. Combining CUORE-0 data with the 19.75~kg$\cdot$yr exposure of $^{130}$Te from the Cuoricino experiment we obtain $T^{0\nu}_{1/2} > 4.0\times 10^{24}~\mathrm{yr}$ at 90%~C.L.~(Bayesian), the most stringent limit to date on this half-life. Using a range of nuclear matrix element estimates we interpret this as a limit on the effective Majorana neutrino mass, $m_{\beta\beta}< 270$ -- $760~\mathrm{meV}$.

nucl-ex

Status of the CUORE and results from the CUORE-0 neutrinoless double beta decay experiments

CUORE is a 741 kg array of TeO2 bolometers for the search of neutrinoless double beta decay of 130Te. The detector is being constructed at the Laboratori Nazionali del Gran Sasso, Italy, where it will start taking data in 2015. If the target background of 0.01 counts/keV/kg/y will be reached, in five years of data taking CUORE will have a 1 sigma half life sensitivity of 10E26 y. CUORE-0 is a smaller experiment constructed to test and demonstrate the performances expected for CUORE. The detector is a single tower of 52 CUORE-like bolometers that started taking data in spring 2013. The status and perspectives of CUORE will be discussed, and the first CUORE-0 data will be presented.

physics.ins-det

CUORE-0 results and prospects for the CUORE experiment

With 741 kg of TeO2 crystals and an excellent energy resolution of 5 keV (0.2%) at the region of interest, the CUORE (Cryogenic Underground Observatory for Rare Events) experiment aims at searching for neutrinoless double beta decay of 130Te with unprecedented sensitivity. Expected to start data taking in 2015, CUORE is currently in an advanced construction phase at LNGS. CUORE projected neutrinoless double beta decay half-life sensitivity is 1.6E26 y at 1 sigma (9.5E25 y at the 90% confidence level), in five years of live time, corresponding to an upper limit on the effective Majorana mass in the range 40-100 meV (50-130 meV). Further background rejection with auxiliary bolometric detectors could improve CUORE sensitivity and competitiveness of bolometric detectors towards a full analysis of the inverted neutrino mass hierarchy. CUORE-0 was built to test and demonstrate the performance of the upcoming CUORE experiment. It consists of a single CUORE tower (52 TeO2 bolometers of 750 g each, arranged in a 13 floor structure) constructed strictly following CUORE recipes both for materials and assembly procedures. An experiment its own, CUORE-0 is expected to reach a sensitivity to the neutrinoless double beta decay half-life of 130Te around 3E24 y in one year of live time. We present an update of the data, corresponding to an exposure of 18.1 kg y. An analysis of the background indicates that the CUORE performance goal is satisfied while the sensitivity goal is within reach.

physics.ins-det

Effect of charging on CdSe/CdS dot-in-rods single-photon emission

The photon statistics of CdSe/CdS dot-in-rods nanocrystals is studied with a method involving post-selection of the photon detection events based on the photoluminescence count rate. We show that flickering between two states needs to be taken into account to interpret the single-photon emission properties. With post-selection we are able to identify two emitting states: the exciton and the charged exciton (trion), characterized by different lifetimes and different second order correlation functions. Measurements of the second order autocorrelation function at zero delay with post- selection shows a degradation of the single photon emission for CdSe/CdS dot-in-rods in a charged state that we explain by deriving the neutral and charged biexciton quantum yields.

quant-ph

The CUORE and CUORE-0 Experiments at Gran Sasso

The Cryogenic Underground Observatory for Rare Events (CUORE) is an experiment to search for neutrinoless double beta decay ($0\nu\beta\beta$) in $^{130}$Te and other rare processes. CUORE is a cryogenic detector composed of 988 TeO$_2$ bolometers for a total mass of about 741 kg. The detector is being constructed at the Laboratori Nazionali del Gran Sasso, Italy, where it will start taking data in 2015. If the target background of 0.01 counts/(keV$\cdot$kg$\cdot$y) will be reached, in five years of data taking CUORE will have an half life sensitivity around $1\times 10^{26}$ y at 90\% C.L. As a first step towards CUORE a smaller experiment CUORE-0, constructed to test and demonstrate the performances expected for CUORE, has been assembled and is running. The detector is a single tower of 52 CUORE-like bolometers that started taking data in spring 2013. The status and perspectives of CUORE will be discussed, and the first CUORE-0 data will be presented.

physics.ins-det

Initial performance of the CUORE-0 experiment

CUORE-0 is a cryogenic detector that uses an array of tellurium dioxide bolometers to search for neutrinoless double-beta decay of ^{130}Te. We present the first data analysis with 7.1 kg y of total TeO_2 exposure focusing on background measurements and energy resolution. The background rates in the neutrinoless double-beta decay region of interest (2.47 to 2.57 MeV) and in the α background-dominated region (2.70 to 3.90 MeV) have been measured to be 0.071 \pm 0.011 and 0.019 \pm 0.002 counts/keV/kg/y, respectively. The latter result represents a factor of 6 improvement from a predecessor experiment, Cuoricino. The results verify our understanding of the background sources in CUORE-0, which is the basis of extrapolations to the full CUORE detector. The obtained energy resolution (full width at half maximum) in the region of interest is 5.7 keV. Based on the measured background rate and energy resolution in the region of interest, CUORE-0 half-life sensitivity is expected to surpass the observed lower bound of Cuoricino with one year of live time.

physics.ins-det

CUORE and beyond: bolometric techniques to explore inverted neutrino mass hierarchy

The CUORE (Cryogenic Underground Observatory for Rare Events) experiment will search for neutrinoless double beta decay of $^{130}$Te. With 741 kg of TeO$_2$ crystals and an excellent energy resolution of 5 keV (0.2%) at the region of interest, CUORE will be one of the most competitive neutrinoless double beta decay experiments on the horizon. With five years of live time, CUORE projected neutrinoless double beta decay half-life sensitivity is $1.6\times 10^{26}$ y at $1σ$ ($9.5\times10^{25}$ y at the 90% confidence level), which corresponds to an upper limit on the effective Majorana mass in the range 40--100 meV (50--130 meV). Further background rejection with auxiliary light detector can significantly improve the search sensitivity and competitiveness of bolometric detectors to fully explore the inverted neutrino mass hierarchy with $^{130}$Te and possibly other double beta decay candidate nuclei.

physics.ins-det

Exploring the Neutrinoless Double Beta Decay in the Inverted Neutrino Hierarchy with Bolometric Detectors

Neutrinoless double beta decay (0nubb) is one of the most sensitive probes for physics beyond the Standard Model, providing unique information on the nature of neutrinos. In this paper we review the status and outlook for bolometric 0nubb decay searches. We summarize recent advances in background suppression demonstrated using bolometers with simultaneous readout of heat and light signals. We simulate several configurations of a future CUORE-like bolometer array which would utilize these improvements and present the sensitivity reach of a hypothetical next-generation bolometric 0nubb experiment. We demonstrate that a bolometric experiment with the isotope mass of about 1 ton is capable of reaching the sensitivity to the effective Majorana neutrino mass (|mee|) of order 10-20 meV, thus completely exploring the so-called inverted neutrino mass hierarchy region. We highlight the main challenges and identify priorities for an R&D program addressing them.

nucl-ex

Searching for neutrinoless double-beta decay of $^{130}$Te with CUORE

Neutrinoless double-beta ($0\nu\beta\beta$) decay is a hypothesized lepton-number-violating process that offers the only known means of asserting the possible Majorana nature of neutrino mass. The Cryogenic Underground Observatory for Rare Events (CUORE) is an upcoming experiment designed to search for $0\nu\beta\beta$ decay of $^{130}$Te using an array of 988 TeO$_2$ crystal bolometers operated at 10 mK. The detector will contain 206 kg of $^{130}$Te and have an average energy resolution of 5 keV; the projected $0\nu\beta\beta$ decay half-life sensitivity after five years of live time is $1.6\times 10^{26}$ y at $1\sigma$ ($9.5\times10^{25}$ y at the 90% confidence level), which corresponds to an upper limit on the effective Majorana mass in the range 40--100 meV (50--130 meV). In this paper we review the experimental techniques used in CUORE as well as its current status and anticipated physics reach.

physics.ins-det